• Title/Summary/Keyword: Low power testing

Search Result 287, Processing Time 0.029 seconds

Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Frequency Spectrum Analysis Method (주파수분석법에 의한 발전소 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk;Lee, In-Cheol;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.10-17
    • /
    • 2000
  • In boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants, conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also, these techniques have low practicality and applied only to component surfaces with good accessibility. It needs to apply a reliable and quantitative ultrasonic nondestructive evaluation method that can be replaced for these equipment. In this study, both artificial creep degradation test using life prediction formula and frequency analysis by ultrasonic tests for crept specimens were carried out for the purpose of nondestructive evaluation for creep damage. As a result of ultrasonic tests for crept specimens, we conformed that the high frequency side spectra decrease and central frequency components shift to low frequency band, and also their bandwidth decreases as increasing creep damage in backwall echos.

  • PDF

Evaluation of Power Performance by Anemometer on WTGS (풍력발전기 너셀에 장착된 풍속계를 이용한 출력성능 평가)

  • Kim, Soo-Sang;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.303-310
    • /
    • 2012
  • We carried out the power performance evaluation for 1.5 MW${\times}$2 by using anemometer installed on WTGS(Wind Turbine Generator System) in the wind farm at Shi-hwa bang-a-mu-ri. In this paper, we compared and analyzed the performance of guaranteed output and measured output of WTGS which includes output curve, output coefficient, AEP(Annual Energy Product) and availability, etc.. The power performance of WTGS was optimized in the low wind speed sections(3 m/s ~ 10 m/s) and the measured output was more produced by AEP 109 % and availability 112 % than the guaranteed output. In addition, we could also cut the high cost of testing WTGS performance by using anemometer as a substitute for weather mast.

The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

A Study on International Standards Related to Power Supplies and Semiconductor Convertors (전원장치 및 반도체 변환장치 관련 국제규격에 관한 연구)

  • Hong, Soon-Chan;Yoo, Jong-Gul;Lee, Ju-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2659-2661
    • /
    • 1999
  • This paper studies the scope and object of international standards related to power supplies and semiconductor convertors. IEC 60478 and IEC 60686 are international standards for stabilized power supplies with DC and AC output, respectively, and IEC 61204 for low-voltage power supply devices with DC output. IEC 60146 : Semiconductor Convertors is a representative international standard in the field of semiconductor convertors. In this field, there are some international standards such as IEC 60971. IEC 61136-1. IEC 61800. and etc.. In this paper, IEC 60686, 60971, 61136-1, and 61240 are mainly studied.

  • PDF

A Study on the reliability analysis of Forest Fire on Polymer Insulators (폴리머 애자의 산불 신뢰성 평가 연구)

  • Lee, Won-Kyo;Choi, In-Hyuk;Hwang, Kab-Cheol;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.460-461
    • /
    • 2008
  • The forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

  • PDF

A Study on Noise Reduction for Auxiliary Power Supply of railway Vehicle Using IGBT (IGBT를 이용한 전동차용 보조전원장치의 소음 저감에 관한 연구)

  • 노애숙;김주범;배기훈;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.280-286
    • /
    • 1998
  • In recent years, the interest in noise increases gradually and the low noise level becomes one of the important performances in electrical equipment for railway vehicle. In the auxiliary power supply, most of the noise is made by the current ripple of alternating current reactor(ACL) which filters the output voltage. And this current ripple results from the voltage harmonics across the ACL. So the noise can be reduced by eliminating the voltage harmonics across the ACL. This paper shows harmonic eliminating technique which is making gating signals of upper and lower inverter have a phase difference in the 12-step inverter type auxiliary power supply. This technique was proved by testing on the developed 180KVA auxiliary power supply using IGBT.

  • PDF

TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter (DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험)

  • Lho, Young Hwan;Hwang, Eui Sung;Jeong, Jae-Seong;Han, Changwoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a PWM-IC (pulse width modulation-integrated circuit) controller, a MOSFET (metal-oxide semiconductor field effect transistor), inductor, capacitor, etc. It is shown that the variation of threshold voltage and the offset voltage in the electrical characteristics of PWM-IC increase by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 4 heavy ions applied for SEL (Single Event Latch-up) make the PWM pulse unstable. Also, the output waveform for the given input in the DC/DC converter is observed by the simulation program with integrated circuit emphasis (SPICE). TID testing on PWM-IC is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the PWM operation is studied at SEL testing after implementation of the controller board.

Activation energy standardization of White LED Phosphor (White LED 형광체의 활성화 에너지 정형화)

  • Jang, In-Hyeok;Kim, Su-Kyoung;Han, Ji-Hoon;Lee, Chang-Hoon;Lim, Houng-Woo
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.117-127
    • /
    • 2013
  • In this paper, we studied the correlation between the activation energy($E_a$) of the raw materials and the structural characteristics of the White LED PKGs. The samples used in the study were composed of low power LED 3type and high power LED 5type. To calculate the activation energy($E_a$) of the White LED PKGs conducted three conditions of high temperature operation test based on the Arrhenius model. The number of samples used in the experiment is 10, respectively. The $T_j$ of Conditions and target specifics expressed $T_{j1}$, $T_{j2}$, $T_{j3}$. The activation energy ($E_a$) of the samples was calculated based on the value of the actually measured lifetime. We investigated the correlation between the activation energy ($E_a$) of the raw materials and the structural characteristics of the White LED PKGs. As a result, White LED PKGs activation energy($E_a$) value was confirmed that the material properties affected more than the structural characteristics of the LED PKGs and we found that activation energy of each LED Model has difference. Normally, The activation energy of phosphor of YAG type was indicated from 0.21 to 0.25[eV] and Silicate type was indicated from 0.12 to 0.16[eV]. According to the results, we confirmed that the activation energy of phosphor of YAG type is higher more than The activation energy of phosphor of Silicate type.

Leak Detection and Evaluation for Power Plant Boiler Tubes Using Acoustic Emission (음향방출을 이용한 보일러튜브 누설평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.45-51
    • /
    • 2004
  • Boiler tubes in power plants are often leaked due to various material degradations including creep and thermal fatigue damage under severe operating conditions such as high temperature and high pressure over an extended period of time. To monitor and diagnose the tubes on site and in real time, the acoustic emission (AE) technology was applied. We developed an AE leak detection system, and used it to study the variation of AE signal from the on-site tubes in response to the changes in the boiler operation condition and to detect the locations of leakage based on it. Detection of leak was performed by acquiring and evaluating the signals in separate regimes of high and low frequency signal. As a result of these studies, we found that on-line monitoring and detection of leak location for boiler tubes is possible using the developed system. Thus, the system is expected to contribute to the safe operation of power plants, and prevent economic losses due to potential leak.

A Study on PV AC-Module with Active Power Decoupling and Energy Storage System

  • Won, Dong-Jo;Noh, Yong-Su;Lim, Hong-Woo;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1894-1903
    • /
    • 2016
  • In general, electrolytic capacitors are used to reduce power pulsations on PV-panels. However, this can reduce the reliability of the PV AC-module system, because electrolytic capacitors have a shorter lifetime than PV-panels. In addition, PV-panels generate irregular power and inject it into the grid because the output power of a PV-panel depends on the surrounding conditions such as irradiation and temperature. To solve these problems, a grid-connected photovoltaic (PV) AC-module with active power decoupling and energy storage is proposed. A parallel bi-directional converter is connected to the AC module to reduce the output power pulsations of PV-panels. Thus, the electrolytic capacitor can be replaced with a film capacitor. In addition, the irregular output power due to the surrounding conditions can be regulated by using a parallel energy storage circuit. To maintain the discontinuous conduction mode at low irradiation, the frequency control method is adopted. The design method of the proposed converter and the operation principles are introduced. An experimental prototype rated at 125W was built to verify the performance of the proposed converter.