• Title/Summary/Keyword: Low noise

Search Result 4,828, Processing Time 0.037 seconds

Implementation of Ku-band Low Noise Block for Global Multi-Band Digital Satellite Broadcasting (글로벌형 다중대역 디지털 위성방송용 Ku-대역 LNB 개발)

  • Kim, Sun Hyo;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.23-28
    • /
    • 2016
  • In this paper, a Multi-Band Ku-band down converter was designed for reception of multi-band digital satellite broadcasting. The Multi-band low-nose down converter was designed to form four local oscillator frequencies (9.75, 10, 10.75 and 11.3GHz) representing a low phase noise due to VCO-PLL with respect to input signals of 10.7 to 12.75GHz and 3-stage low noise amplifier circuit by broadband noise matching, and to select an one band of intermediate frequency (IF) channels by digital control. The developed low-noise downconverter exhibited the full conversion gain of 64dB, and the noise figure of low-noise amplifier was 0.7dB, the P1dB of output signal 15dBm, and the phase noise -73dBc@100Hz at the band 1 carrier frequency of 9.75GHz. The low noise block downconverter (LNB) for receiving four-band digital satellite broadcasting designed in this paper can be used for satellite broadcasting of vessels navigating international waters.

Implementation of Wideband Low Noise Down-Converter for Ku-Band Digital Satellite Broadcasting (Ku-대역 광대역 디지탈 위성방송용 저 잡음하향변환기 개발)

  • Hong, Do-Hyeong;Lee, Kyung Bo;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2016
  • In this paper, wideband Ku-band downconverter was designed to receiver digital satellite broadcasting. The low-nose downconverter was designed to form four local oscillator frequencies(9.75, 10, 10.75 and 11.3 GHz) representing a low phase noise due to VCO-PLL with respect to input signals of 10.7 to 12.75 GHz and 3-stage low noise amplifier circuit by broadband noise matching, and to select intermediate frequency bands by digital control. The developed low-noise downconverter exhibited the full conversion gain of 64 dB, and the noise figure of low-noise amplifier was 0.7 dB, the P1dB of output signal 15 dBm, and the phase noise -85 dBc@10kHz at the band 1 carrier frequency of 9.75 GHz. The low noise block downconverter(LNB) for wideband digital satellite broadcasting designed in this paper can be used for global satellite broadcasting LNB.

A Study on the Structure Improvement of Bracket Housing for Structural Noise and Vibration Reduction in Hydraulic Breaker (유압 브레이커의 구조 소음.진동 저감을 위한 브래킷 하우징의 구조 개선에 관한 연구)

  • Kim, Bong-Suk;Kim, Min-Gi;Byun, Dong-Woo;Lee, Seong-Min;Lee, Soo-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.108-115
    • /
    • 2006
  • A hydraulic breaker is widely utilized for many civil engineering areas for the purpose of destroying objects such as rocks, concrete, or road. However, since the high-level noise and vibration by a hydraulic breaker is one of the major sources of environmental noise and recently the environmental regulations on construction equipments are also getting more strengthened, in order to solve such problems, it is certainly necessary to design and develop a hydraulic breaker with low noise and low vibration. This research is to understand the noise characteristics through the noise test and acoustic analysis of the bracket housing in a hydraulic breaker and to identify the element part to be modified based on the result of the element contribution analysis. An improved breaker model including X-typed rib shows the result of low-noise level within target frequency band compared with a commercial breaker model.

A Laboratory Study on Low Frequency Noise Assessment based on Noise Acceptability Limit (소음 수응 한계를 고려한 저주파 소음평가에 대한 실험적 연구)

  • Hong, Seung-Ki;Kim, Jae-Hwan;Kim, Kyu-Tae;Lee, Soo-Gab
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.8
    • /
    • pp.736-740
    • /
    • 2007
  • A laboratory study on low frequency noise assessment has been carried out to evaluate the relevance of the weighting curve. Especially, the A-weighting curve which is used in most noise assessments has been evaluated using the acceptability limit in this study. The acceptability limit is one of the indicators in which the subjective responses were well-reflected. For the measurement of the acceptability limit, pure tone stimuli were used in the frequency range between 20 and 200 Hz. The measurement was proceeded in the anechoic chamber to minimize the background noise level. A total of 29 test subjects, who were aged between 19 to 33 years, participated in this study. They had been exposed to various stimuli for about 1 hour by supra-aural earphone. The measurement consisted of two listening sessions: hearing threshold and the acceptability limit session. The results showed that the tendency of the acceptability limit curve was approximately equal to C-weighting curve which had been found to be superior to A-weighting curve in assessment of low frequencies.

Low Frequency Noise Characteristics of the 180nm MOSFETs

  • Yoon, Young-Chang;Lee, Ho-Cheol;Kang, In-Man;Shin, Hyung-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.861-864
    • /
    • 2005
  • Performing accurate and repeatable low frequency noise measurement is critical for modeling and simulation of flicker noise. Through the accurate and repeatable on-wafer measurement, low frequency noise characteristics of the 0.18 ${\mu}m$ n-MOSFETs are discussed. And on-wafer flicker noise measurement system is presented. The on-wafer measurement system consists of cascade probe station, low noise current amplifier (SR570), and dynamic signal analyzer (HP35670A).

  • PDF

Low Phase Noise CMOS VCO with Hybrid Inductor

  • Ryu, Seonghan
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.3
    • /
    • pp.158-162
    • /
    • 2015
  • A low phase noise CMOS voltage controlled oscillator(VCO) for multi-band/multi-standard RF Transceivers is presented. For both wide tunability and low phase noise characteristics, Hybrid inductor which uses both bondwire inductor and planar spiral inductor in the same area, is proposed. This approach reduces inductance variation and presents high quality factor without custom-designed single-turn inductor occupying large area, which improves phase noise and tuning range characteristics without additional area loss. An LC VCO is designed in a 0.13um CMOS technology to demonstrate the hybrid inductor concept. The measured phase noise is -121dBc/Hz at 400KHz offset and -142dBc/Hz at 3MHz offset from a 900MHz carrier frequency after divider. The tuning range of about 28%(3.15 to 4.18GHz) is measured. The VCO consumes 7.5mA from 1.3V supply and meets the requirements for GSM/EDGE and WCDMA standard.

System optimization of the low noise Wave Fan (저소음 Wave Fan 의 System 최적화)

  • Cho, Kyung-Seok;Kim, Woo-June;Joo, Won-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1100-1103
    • /
    • 2007
  • For the past decade many effort has been delivered to understand noise generation mechanism for the small size engine cooling fan. As a result of that effort, the low noise fan such as the Wave fan was developed. Now the Wave fan becomes the well known low noise engine cooling fan. But in case of the new car development, the system in the new car will be different from previous one. So we need system optimization for every new model. In case of special application, a low speed fan should be developed to match system requirement. In that case, we meet severe engineering requirement by conducting fan system optimization instead of the simple fan scaling. In this paper, I will show you the system optimize process.

  • PDF

Driving Method for Mis-discharge Improvement at Low Temperature in AC PDP (AC PDP의 저온에서의 오방전 개선을 위한 구동 방법)

  • Kim, Gun-Su;Lee, Seok-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1157-1165
    • /
    • 2009
  • In AC-PDP, it is necessary to achieve high luminance efficiency, high luminance and high definition by adopting technologies such as high xenon concentration, MgO doping, and long gap. However, it is very difficult to apply above technologies because they make the driving voltage margin reduced. Especially, high Xe concentration technology for high efficacy makes not only the driving voltage margin reduced but also the stability of reset discharge decreased at low temperature. In this paper, we studied temperature and voltage dependent stability of reset discharge and present the experimental results of the discharge characteristics at low temperature. In addition, we suggested the mechanism of bright noise and black noise at low temperature. Finally, we proposed double reset waveform to improve the bright noise and descending scan time method to improve the black noise.

Case History of Low Vibration and Low Noise Granular Pile Method in the Area of Incurred the Popular Enmity (민원발생지역에서의 저진동$\cdot$저소음 Granular Pile의 시공사례)

  • Chun, Byung-Sik;Kim, Baek-Young
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.176-181
    • /
    • 2003
  • Damages by vibration and noise due to the construction performance are increasing. The rise of construction demand and enlargement of equipments are major reasons of this damage. As a result, the enmity of the people is provoked and this appears to be an obstacle of construction work. Especially, in case of ground improvement construction. Casing pipe is inserted into the Sand Drain, Sand Compaction Pile and Vibrated Crushed-stone Pile by vibration power when carrying out. Hence, a pillar is formed and it creates vibration and noise. This causes a lot of restrictions to construction condition. The low Vibration and low noise construction equipments uses earth auger and hydrulic cylinder for insertion and chopping operation instead of vibro hammer, which is the source of vibration and noise. This minimize ground disturbanceand decrease vibration and noise successfully, but increase chopping effect greatly. Thus, this new equipment is not only suitable for environment but also excellent engineering method of construction.

  • PDF

A Study on the Noise Measurement Method of Wind Power Facilities (풍력발전시설 소음 측정 방법에 대한 고찰)

  • YoungJin Lee;Jongtae Lee;Hyunkyung Min;Sunyong Kwon;Byungchan Lee
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.279-290
    • /
    • 2023
  • Recently, as wind farms using wind power as new and renewable energy have been installed nationwide, noise problems have emerged. The environmental impact assessment and post-environmental impact assessment also require the measurement of background noise and low-frequency noise for wind farms, especially by applying the living noise measurement method according to the low-frequency noise management guidelines issued by the Ministry of Environment in 2018. Due to the nature of wind power generators that generate loud noise in high winds, noise measurement should be made at high winds, but when wind speed increases, wind noise increases and living noise and low-frequency noise are not properly evaluated. Therefore, the type of noise generated by wind power generators was confirmed, and matters to be considered when measuring wind noise such as wind noise were confirmed.