• Title/Summary/Keyword: Low loss

Search Result 5,057, Processing Time 0.043 seconds

Quadrant Analysis in Correlation between Mechanical and Electrical Properties of Low-Temperature Conductive Film Bonded Crystalline Silicon Solar Cells

  • Baek, Su-Wung;Choi, Kwang-Il;Lee, Woo-Hyoung;Lee, Suk-Ho;Cheon, Chan-Hyuk;Hong, Seung-Min;Lee, Kil-Song;Shin, Hyun-Woo;Yan, Yeon-Won;Lim, Cheolhyun
    • Current Photovoltaic Research
    • /
    • v.3 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • In this study, we analyzed the correlation between mechanical and electrical properties of low-temperature conductive film (LT-CF) bonded silicon solar cells by a quadrant analysis (horizontal axis (peeling strength), vertical axis (power loss)). We found that a series of points with various bonding parameters such as bonding temperature, pressure and time were distributed in the different three regimes; weak regime (Q2: weak bonding strength and high power loss), moderate regime (Q4 : strong bonding strength and low power loss) and hard regime (Q3 : weak bonding strength and low power loss). Using this analogous technique, it was possible to fabricate the LT-CF bonded silicon solar cells with the various conditions displayed in Q3 of the quadrant plots, possessing the peeling strength of ~ 1N/mm and power loss of 2~3%.

Blood haematology, muscle pH and serum cortisol changes in pigs with different levels of drip loss

  • Koomkrong, Nunyarat;Boonkaewwan, Chaiwat;Laenoi, Watchara;Kayan, Autchara
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.12
    • /
    • pp.1751-1755
    • /
    • 2017
  • Objective: An experiment was conducted to study the blood haematology, muscle pH, and serum cortisol changes in pigs with different levels of drip loss. Methods: Two groups (low and high) of 20 animals were selected from 100 pigs based on drip loss. All [$Duroc{\times}(Large\;White{\times}Landrace)$] pigs were slaughtered according to standard slaughtering procedures. At exsanguinations, blood samples were taken for the haematological parameters and serum cortisol analysis. The muscle samples were taken from longissimus dorsi muscle to evaluate the muscle pH and drip loss. Results: Haematological parameters of low drip loss group showed higher content of white blood cells and monocytes than high drip loss group (p<0.05). The low drip loss group had higher muscle pH at 45 min (p<0.05) and 24 h (p<0.001) post-mortem than the high drip loss group. However, there was no significant difference in serum cortisol levels (p>0.05). Conclusion: Drip loss is mainly affected by the muscle pH decline after slaughter and also might be affected by white blood cells and monocytes.

Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source (단상전원에 접속된 3상 유도전동기의 손실분석)

  • Kim, Do-Jin;Jwa, Chong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.

A Broadband Digital Step Attenuator with Low Phase Error and Low Insertion Loss in 0.18-${\mu}m$ SOI CMOS Technology

  • Cho, Moon-Kyu;Kim, Jeong-Geun;Baek, Donghyun
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.638-643
    • /
    • 2013
  • This paper presents a 5-bit digital step attenuator (DSA) using a commercial 0.18-${\mu}m$ silicon-on-insulator (SOI) process for the wideband phased array antenna. Both low insertion loss and low root mean square (RMS) phase error and amplitude error are achieved employing two attenuation topologies of the switched path attenuator and the switched T-type attenuator. The attenuation coverage of 31 dB with a least significant bit of 1 dB is achieved at DC to 20 GHz. The RMS phase error and amplitude error are less than $2.5^{\circ}$ and less than 0.5 dB, respectively. The measured insertion loss of the reference state is less than 5.5 dB at 10 GHz. The input return loss and output return loss are each less than 12 dB at DC to 20 GHz. The current consumption is nearly zero with a voltage supply of 1.8 V. The chip size is $0.93mm{\times}0.68mm$, including pads. To the best of the authors' knowledge, this is the first demonstration of a low phase error DC-to-20-GHz SOI DSA.

High Performance Polymeric Optical Waveguide Devices (고성능 폴리머 광도파로 소자)

  • O, Min-Cheol;No, Yeong-Uk;Lee, Hyeong-Jong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.02a
    • /
    • pp.292-295
    • /
    • 2005
  • Variable optical attenuators (VOA) made of low-loss fluorinated polymers are demonstrated which shows a low operating power less than 30 mW due to the superior thermo-optic effect of polymer material and a low insertion loss less than 1.0 dB by incorporating highly fluorinated polymers to reduce the absorption loss at 1550 nm. An attenuator-integrated low-crosstalk polymeric digital optical switch (DOS) is also demonstrated. The switch and attenuator shares a single connected electrode which is controlled by a single current source. Due to the simple structure of the integrated attenuator, the device length is reduced to 1 cm so as to provide low insertion loss of 0.8 and 1.1 dB for 1300 and 1550 nm, respectively. The attenuator radiates remained optical signal on the switch-off branch in order to decrease the switching crosstalk to be less than -70 dB with an applied electrical power of 200 mW.

  • PDF

Loss improvement of star couplers and arrayed waveguide grating wavelength filter (성형결합기 및 광도파로열 격자 파장 필터 손실특성 개선)

  • 박준오;정영철;백수현;이형종
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2002
  • In the conventional star coupler, a certain amount of loss should be expected because lateral diffraction is used for the power distribution. In this paper, we propose a new design of a low loss star coupler which employs UV-written tapered waveguides and an AWG based on the low loss star couplers, and investigate their various characteristics. The loss of the UV-written star coupler is lower than that of the conventional star coupler, and the AWG device based on the UV-written star couplers shows low loss characteristics.

Expression levels of filaggrin-2 in relation to drip loss in pigs

  • Kayan, Autchara;Koomkrong, Nunyarat
    • Animal Bioscience
    • /
    • v.35 no.4
    • /
    • pp.624-630
    • /
    • 2022
  • Objective: The aim of this study was to investigate the expression level of filaggrin-2 (FLG2) in correlation with drip loss. Methods: The muscle samples were randomly taken from a local meat supplier. Samples were taken from Longissimus lumborum muscles to evaluate the drip loss (n = 100). Five muscles per group (low and high drip loss) were selected to evaluate FLG2 mRNA and protein expression levels. Results: mRNA of FLG2 gene was not significantly different in pigs with different levels of drip loss (p>0.05). Statistical analysis revealed that FLG2 protein expression levels were significantly different between the drip loss groups. Western blot revealed that the high drip loss group had higher FLG2 protein expression level than the low drip loss group (p<0.001). Moreover, immunohistochemistry revealed the high signal intensity was on the muscle cell membrane and cytoplasm. Conclusion: FLG2 protein might play roles in drip loss of pork and will provide the basis for information to improving meat quality traits in pigs.

Performance Characteristic of a Pipe Type Centrifugal Pump (파이프형 원심펌프의 성능특성에 관한 실험적 연구)

  • Yu, HyeonJu;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.32-36
    • /
    • 2012
  • The positive displacement pump and the regenerative pump are widely used in the range of low specific speed, $n_s{\leq}100$[rpm, m3/min, m]. The positive displacement pump is not suitable for miniaturization and operation in high rotational speed. The regenerative pump has a problem with large leakage flow and low efficiency. While the centrifugal pump has advantages of high efficiency, miniaturization and high rotational speed, efficiency drops sharply with decrease in specific speed. Therefore the purpose of this study is to design a new type of centrifugal pump that has advantages of centrifugal pumps in operation in low specific speed. The name of this new type of pump was called 'Pipe type centrifugal pump', since the flow path through the impeller is simple circular pipe. Due to the simple shape of impeller, the manufacturing process is simple and cost is low. There is strong jet flow at the outlet of the impeller. This jet induces flow path loss, meridional dynamic pressure loss and mixing loss. Large disk friction makes the efficiency be limitted in the range of low specific speed. Even though the loss and the low efficiency, 'Pipe type centrifugal pump' represents stable performance, affordable pressure ratio and efficiency better than that of other low specific speed pumps.

Bottom Loss Variation of Low-Frequency Sound Wave in the Yellow Sea (황해에서 저주파 음파의 해저손실 변동)

  • Kim, Bong-Chae
    • Ocean and Polar Research
    • /
    • v.29 no.2
    • /
    • pp.113-121
    • /
    • 2007
  • The sound wave in the sea propagates under the effect of water depth, sound speed structure, sea surface roughness, bottom roughness, and acoustic properties of bottom sediment. In shallow water, the bottom sediments are distributed very variously with place and the sound speed structure varying with time and space. In order to investigate the seasonal propagation characteristics of low-frequency sound wave in the Yellow Sea, propagation experiments were conducted along a track in the middle part of the Yellow Sea in spring, summer, and autumn. In this paper we consider seasonal variations of the sound speed profile and propagation loss based on the measurement results. Also we quantitatively investigate variation of bottom loss by dividing the propagation loss into three components: spreading loss, absorption loss, and bottom loss. As a result, the propagation losses measured in summer were larger than the losses in spring and autumn, and the propagation losses measured in autumn were smaller than the losses in spring. The spreading loss and the absorption loss did not show seasonal variations, but the bottom loss showed seasonal variations. So it was thought that the seasonal variation of the propagation loss was due to the seasonal change of the bottom loss and the seasonal variation of the bottom loss was due to the change of the sound speed profile by season.

Core loss Consideration for d-q axis Inductance Measurement of IPMSM (매입형 영구자석 동기 전동기의 d-q축 인덕턴스 측정 및 철손의 고려)

  • Kwon, Soon-O;Choi, Jin-Chul;Lee, Woo-Taek;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.864-865
    • /
    • 2008
  • This paper deals with d-q axis inductance measurements of IPMSM considering core loss at low speed. d-q axis inductance measurements generally are conducted at rated speed and parallel core loss model can be used to exclude core loss effects on inductances. Core loss is generally modeled parallel to input terminal of d-q axis equivalent circuit. Therefore, the effect of core loss on inductance calculation can be varied by core loss modeling. In this paper, d-q axis inductance is calculated parallel and series core loss modeling. Calculated inductances are compared to FEA results and it is concluded that series core loss modeling is more closed to FEA results at low speed.

  • PDF