• Title/Summary/Keyword: Low insertion

Search Result 629, Processing Time 0.024 seconds

Effect of an Au Nanodot Nucleation Layer on CO Gas Sensing Properties of Nanostructured SnO2 Thin Films

  • Hung, Nguyen Le;Kim, Hyojin;Kim, Dojin
    • Korean Journal of Materials Research
    • /
    • v.24 no.3
    • /
    • pp.152-158
    • /
    • 2014
  • We report the effect of the fabric of the surface microstructure on the CO gas sensing properties of $SnO_2$ thin films deposited on self-assembled Au nanodots ($SnO_2$/Au) that were formed on $SiO_2/Si$ substrates. We characterized structural and morphological properties, comparing them to those of $SnO_2$ thin films deposited directly onto $SiO_2/Si$ substrates. We observed a significant enhancement of CO gas sensing properties in the $SnO_2$/Au gas sensors, specifically exhibiting a high maximum response at $200^{\circ}C$ and quite a low detection limit of 1 ppm level in dry air. In particular, the response of the $SnO_2/Au$ gas sensor was found to reach the maximum value of 32.5 at $200^{\circ}C$, which is roughly 27 times higher than the response (~1.2) of the $SnO_2$ gas sensor obtained at the same operating temperature of $200^{\circ}C$. Furthermore, the $SnO_2/Au$ gas sensors displayed very fast response and recovery behaviors. The observed enhancement in the CO gas sensing properties of the $SnO_2/Au$ sensors is mainly ascribed to the formation of a nanostructured morphology in the active $SnO_2$ layer having a high specific surface-reaction area by the insertion of a nanodot form of Au nucleation layer.

Modelling of the Heat and Mass Transfer in a Liquid Desiccant Dehumidifier with Extended Surface (확장표면을 적용한 액체식 제습기의 열물질 전달 모델링)

  • Chang, Y.S.;Lee, D.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.303-311
    • /
    • 2011
  • This study presents a new idea of liquid desiccant dehumidifier with extended surface to improve the compactness. Extended surface is inserted between vertical cooling tubes, and the liquid desiccant flows down along the tube walls and the extended surface as well. Though the extended surface contributes to the increase in the mass transfer area, the effect tends to be limited because less conductive non-metallic materials need to be applied due to the high corrosiveness of liquid desiccant. To analyze the effects of the extended surface insertion, mathematical modelling and numerical integration are performed for the heat and mass transfer in the liquid desiccant dehumidifier. The results show that, though the liquid desiccant on the extended surface is heated due to the moisture absorption, the temperature can be maintained by periodic mixing at the contact points between the tube and the extended surface with the liquid desiccant stream from the tube side at a relatively low temperature. This implies the absorption heat from the extended surface side can be removed effectively by mixing, which leads to a substantial improvement of the dehumidification in the liquid desiccant dehumidifier with extended surface. When the interval of the extended surface, $p_e/L$, is less than 0.1, the dehumidification is shown to increase by more than two times compared with that without extended surface.

Coplanar Waveguides Fabricated on Oxidized Porous Silicon Air-Bridge for MMIC Application (다공질 실리콘 산화막 Air-Bridge 기판 위에 제작된 MMIC용 공면 전송선)

  • 박정용;이종현
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.5
    • /
    • pp.285-289
    • /
    • 2003
  • This paper proposes a 10 ${\mu}{\textrm}{m}$ thick oxide air-bridge structure which can be used as a substrate for RF circuits. The structure was fabricated by anodic reaction, complex oxidation and rnicrornachining technology using TMAH etching. High quality films were obtained by combining low temperature thermal oxidation (50$0^{\circ}C$, 1 hr at $H_2O$/O$_2$) and rapid thermal oxidation (RTO) process (105$0^{\circ}C$, 2 min). This structure is mechanically stable because of thick oxide layer up to 10 ${\mu}{\textrm}{m}$ and is expected to solve the problem of high dielectric loss of silicon substrate in RF region. The properties of the transmission line formed on the oxidized porous silicon (OPS) air-bridge were investigated and compared with those of the transmission line formed on the OPS layers. The insertion loss of coplanar waveguide (CPW) on OPS air-bridge was (about 1 dB) lower than that of CPW on OPS layers. Also, the return loss of CPW on OPS air-bridge was less than about - 20 dB at measured frequency region for 2.2 mm. Therefore, this technology is very promising for extending the use of CMOS circuitry to higher RF frequencies.

A Design of the Dielectric Resonator BandPass Filters with attenuation poles for the PCS Channel Combiner (PCS Channel Combiner 구현을 위한 감쇄극을 갖는 유전체 공진기 대역통과 여파기의 설계)

  • Kang, Hyun-Taek;Myung, Sung-Ho;Kim, Chul-Soo;Park, Jun-Seok;Ahn, Dal;Park, Jong-Chul;Park, Sung-Yuel;Kim, Geun-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.4
    • /
    • pp.52-58
    • /
    • 2000
  • In this paper, the novel dielectric resonator bandpass filter for Korea personal communication service channel combiner is proposed. The equivalent circuit of the channel bandpass filter is derived using the lumped elements. Proposed channel bandpass filter provides compact size, low insertion loss, two attenuation poles in the stop band, and excellent temperature characteristics. Two channel filters are combined with proposed dielectric resonator filter configuration to implement the 2-channel combiner. Experimental results show the validity of the proposed dielectric resonator channel bandpass filter.

  • PDF

Design and Fabrication of 5-Bit Broadband MMIC Phase Shifter (5-Bit 광대역 MMIC 위상 변위기 설계 및 제작)

  • 정상화;백승원;이상원;정기웅;정명득;우병일;소준호;임중수;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.2
    • /
    • pp.123-129
    • /
    • 2002
  • 5-bit broadband MMIC phase shifter has been designed and fabricated. For the broadband performance, 11.25$^{\circ}$, 22.5$^{\circ}$, 45$^{\circ}$ and 90$^{\circ}$ bit have been designed with Lange coupler and 180$^{\circ}$ bit has been implemented by using shorted coupled line with Lange coupler and $\pi$-network of transmission line. Due to Lange coupler with large size, the Lange couplers have been folded far circuit size reduction. Low loss PIN diode has been utilized as a switch for each bit. Fabricated 5-bit broadband phase shifter shows the measured results that RMS phase error of 5 major phases is 3.5$^{\circ}$, maximum insertion loss is 12.5 dB, and maximum input and output return loss are 7 dB and 10 dB, respectively. The size of fabricated phase shifter is 6.5$\times$5.3 $ extrm{mm}^2$.

Metal-defined Electro-Optic Polymer Waveguide Operating at both $1.31{\mu}m$ and $1.55{\mu}m$ Wavelength ($1.31{\mu}m$ and $1.55{\mu}m$ 파장에서 금속 defined Electro-Optic Polymer Waveguide)

  • Park, G.C.;Lee, J.;Chung, H.C.;Jeong, W.J.;Yang, H.H.;Yoon, J.H.;Park, H.R.;Gu, H.B.;Lee, K.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05c
    • /
    • pp.21-23
    • /
    • 2004
  • We report experimental results demonstrating a novel metal defined polymer optical waveguide with a low loss in electro-optic polymers for the first time. The polymer optical waveguides are created using a metal film on the top of upper cladding without any conventional etching process. The fabricated waveguides have an excellent lateral optical mode confinement at both 1.31 ${\square}m$ and 1.55 ${\square}m$ wavelength, resulting in a fiber-to lens optical insertion loss of ~ 7 dB at 1.55 ${\square}m$ and ~4.5 dB at 1.31 ${\square}m$ wavelength in a 3.5cm total length for TM polarizations, respectively. We also present the optical loss dependence of the waveguide as a function of optical wavelengths. These results may be used in the complex design of integrated polymer optical circuits that need simpler and cheaper fabrication process.

  • PDF

The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets

  • Jun, Sang Ho;Park, Chang-Joo;Hwang, Suk-Hyun;Lee, Youn Ki;Zhou, Cong;Jang, Hyon-Seok;Ryu, Jae-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.8.1-8.6
    • /
    • 2018
  • Background: This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Methods: Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. Results: The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg (R = 0.606, P = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Conclusions: Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.

Active optical coupler using the side polished single mode fiber and thermo-optic polymer multimode planar waveguide (측면 연마된 단일모드 광섬유와 열 광학 다중모드 평면도파로를 이용한 능동형 광 결합기)

  • 김광택;유호종;김성국;이소영;송재원;이상재;김시홍;강신원
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.248-253
    • /
    • 1999
  • In this paper, we have investigated a fiber type active coupler which utilizes the mode coupling between the side polished single mode optical fiber and the active multimode planar waveguide. The proposed device can be used for not only tunable wavelength filter or optical intensity modulator but also a tool for measuring optical properties of guiding material such as refractive index, birefringence, electro-optic coefficient, and thermo-optic coefficient. We gave designed and optimized a coupler structure using the BPM and fabricated the device using thermo-optic polymer as active planar waveguide overlay. The device showed that insertion loss was less then 0.5 dB, extinction ratio was -13 dB at the resonance wavelength, and the wavelength tunablity due to thermo-optic effect was -1.5 nm/$^{\circ}C$. The active coupler using thermo-optic effect can be used as a wavelength tunable filer, an optical intensity modulator and an optical sensor. pulses that are subsequently compressed by a dispersive optical fiber. Experimental results show that $sech^2$ shape pulses with a pulse width of ~14 ps and a time bandwidth product of ~0.34 are successfully generated at 10 GHz repetition rate. In contrast to other methods, such as higher order soliton compression, this approach does not depend on the optical power and thus shows promise for application to low-power lasers.

  • PDF

PCR-RFLP and Sequence Analysis of the rDNA ITS Region in the Fusarium spp.

  • Min, Byung-Re;Lee, Young-Mi;Choi, Yong-Keel
    • Journal of Microbiology
    • /
    • v.38 no.2
    • /
    • pp.66-73
    • /
    • 2000
  • To investigate the genetic relationship among 12 species belonging to the Fusarium section Martiella, Dlaminia, Gibbosum, Arthrosporiella, Liseola and Elegans, the internal transcribed spacer(ITS) regions of ribosomal DNA (rDNA) were amplified with primer pITS1 and pITS4 using the polymerase chain reaction(PCR). After the amplified products were digested with 7 restriction enzymes, restriction fragment length polymorphism (RFLP) patterns were analyzed. The partial nucleotide sequences of the ITS region were determined and compared. Little variation was observed in the size of the amplified product having sizes of 550bp or 570bp. Based on the RFLP analysis, the 12 species studied were divided into 5 RFLP types. In particular, strains belonging to the section Martiella were separated into three RFLP types. Interestingly, the RFLP type of F. solani f. sp. piperis was identical with that of isolates belonging to the section Elegans. In the dendrogram derived from RFLP analysis of the ITS region, the Fusarium spp. examined were divided into two major groups. In general, section Martiella excluding F. solani f. sp. piperis showed relatively low similarity with the other section. The dendrogram based on the sequencing analysis of the ITS2 region also gave the same results as that of the RFLP analysis. As expected, 5.8S, a coding region, was highly conserved, whereas the ITS2 region was more variable and informative. The difference in the ITS2 region between the length of F. solani and its formae speciales excluding F. solani f. sp. piperis and that of other species was caused by the insertion/deletion of nucleotides in positions 143-148 and 179-192.

  • PDF

Design, Implementation, and Performance Evaluation of an Embedded RDBMS Miracle (Miracle 임베디드 RDBMS 설계, 구현 및 성능 평가)

  • Seo, Nam-Won;Kim, Keong-Yul;Kim, Su-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3227-3235
    • /
    • 2011
  • In this paper, a relational embedded DBMS was designed and a prototype 'Miracle' RDBMS (MDB) was developed. MDB is written in C and works on Unix, Linux and Windows platforms locally. It accesses database through SQL interfaces and API functions and uses $B^+$ tree index. It guarantees ACID in transactions and supports low concurrency control and processes SQL statements on a single table. To evaluate the performance of MDB on an ARM board EZ-S3C6410 and to compare the performance of MDB with that of SQLite, an experiment was carried out to estimate processing times for insertion, selection, update and deletion operations. The result shows that the average times for selections and insertions in MDB were 38.46% and 22.86% faster than those in SQLite, respectively, but the average times for updates and deletions in SQLite were 28.33% and 26.00% faster than MDB, respectively, This experiment shows that fetching data from database and sending data to database in MDB is faster than in SQLite, but $B^+$ tree index is implemented more effectively in SQlite than in MDB.