• 제목/요약/키워드: Low frequency

검색결과 11,381건 처리시간 0.04초

Effect of a 60Hz electromagnetic field on the frequency of bleomycin-induced HPRT gene mutation and 1,2,4-benzenetriol-induced sister chromatid exchanges in CHO cell

  • Chung, Hai-Won;Kang, Su-Jin;Lee, Young-Joon;Kim, Su-Young
    • Journal of Radiation Protection and Research
    • /
    • 제27권2호
    • /
    • pp.81-87
    • /
    • 2002
  • The interaction of low density extremely low frequency magnetic field (ELF MF) in the frequency of hypoxanthine-guanine phosphoribosyltransferase (HPRT) mutation induced by bleomycin and on the frequency of sister chromatid exchanges (SCEs) induced by 1,2,4-benzenetriol(BT) was demonstrated. CHO cells pretreated with bleomycin or 1,2,4-benzenetriol were exposed for 24hrs to a sinusoidal 0.8mT magnetic field at 60Hz. Frequency of HPRT mutation and SCEs were determined. ELF MF exposure led to a two-fold increase of the frequency of HPRT mutation induced by bleomycin. No increase of mutation frequency was observed by ELF MF alone ELF MF also increased the frequency of SCEs induced by BT while no Increase of SCE frequencies were observed by ELF MF alone. These results suggest that low density ELF MF field would art as an enhancer rather than as an initiator of mutagenic effects in CHO cell.

ZCS를 이용한 고주파 공진형 상용주파수 전원에 관한 연구 (A Study on Commercial Frequency Source with High Frequency Resonant Type using ZCS)

  • 김종해;김동희;노채균;구태근;배상준;이봉섭
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.448-454
    • /
    • 1999
  • This paper describes a new dc-ac inverter system which for achieving sinusoidal ac waveform makes use of parallel loaded high frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. A forced discontinuous conduction mode is used to realize the quasi-sinusoidal pulse in each switching period. Therefore the inverter generates sinusoidal modulated output voltage including carrier frequency that is resonant frequency. Carrier frequency components of modulated output voltage is filtered by low pass filter. Since current through switches is always zero at its turn-on in the proposed inverter, low stress and low switching loss is achieved. Operating characteristics of the proposed system is analyzed in per unit system using computer simulation. The output voltage of if includes low harmonics and it is almost close to sine wave. Also, the theoretical analysis is proved through the experimental test.

  • PDF

A Noisy Infrared and Visible Light Image Fusion Algorithm

  • Shen, Yu;Xiang, Keyun;Chen, Xiaopeng;Liu, Cheng
    • Journal of Information Processing Systems
    • /
    • 제17권5호
    • /
    • pp.1004-1019
    • /
    • 2021
  • To solve the problems of the low image contrast, fuzzy edge details and edge details missing in noisy image fusion, this study proposes a noisy infrared and visible light image fusion algorithm based on non-subsample contourlet transform (NSCT) and an improved bilateral filter, which uses NSCT to decompose an image into a low-frequency component and high-frequency component. High-frequency noise and edge information are mainly distributed in the high-frequency component, and the improved bilateral filtering method is used to process the high-frequency component of two images, filtering the noise of the images and calculating the image detail of the infrared image's high-frequency component. It can extract the edge details of the infrared image and visible image as much as possible by superimposing the high-frequency component of infrared image and visible image. At the same time, edge information is enhanced and the visual effect is clearer. For the fusion rule of low-frequency coefficient, the local area standard variance coefficient method is adopted. At last, we decompose the high- and low-frequency coefficient to obtain the fusion image according to the inverse transformation of NSCT. The fusion results show that the edge, contour, texture and other details are maintained and enhanced while the noise is filtered, and the fusion image with a clear edge is obtained. The algorithm could better filter noise and obtain clear fused images in noisy infrared and visible light image fusion.

가진주파수 이동현상을 이용한 저주파 가진기의 개발 (Development of a Low Frequency Vibration Shaker Using Force Frequency Shifting)

  • 이건명;;이정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.182-186
    • /
    • 2002
  • If a sinusoidal excitation force moves back and forth along a structure with a certain frequency, the structure will be excited with the difference frequency of these two frequencies. A low frequency vibration shaker has been developed using this force frequency shifting without actually moving a shaker. The shaker consists of an ordinary eccentric mass shaker, a plate, constant springs, and time varying dampers. The dampers are turned on and off in a sequential manner to simulate a traveling slide of an excitation force. The operation of the shaker is simulated by solving the equations of motion of the shaker. Characteristics of the shaker have been found and they will be utilized to design efficient low frequency shakers.

  • PDF

System indentification using multiple decimation method and design of PID-ATC

  • Byun, Hwang-Woo;Moon, Joon-Ho;Lee, In-Hee;Lee, Un-Cheol;Kim, Lark-Kyo;Nam, Moon-Hyon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.682-688
    • /
    • 1994
  • LSM(Least-Squares Method) has inherent limitation that precise system identification over wide frequency band is difficult especially at low frequency hand. In this paper we propose to use decimation, a spectrum analysis method widely used in signal processing. The merits of decimation are the flexibility of selection of the frequency hand concerned and the function of LPF(Low Pass Filter). In this paper, frequency-domain is divided into separate frequency bands which will be combined into full frequency-domain by using MDM(Multiple Decimation Method). In this way, free selection of sampling frequency for each hand is possible and the low frequency oscillation modes of LSM are avoided.

  • PDF

Dynamic Scaling을 이용한 저전력 시스템의 설계 (Design of Low Power System using Dynamic Scaling)

  • 김도훈;김양모;김승호;이남호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.282-285
    • /
    • 2002
  • In this paper, we designed of low power system by using dynamic scaling. As an effective low-power design, dynamic voltage/frequency scaling recently has received a lot of attention. In dynamic frequency scheme, all execution cycles are driven by the clock frequency that switched frequency dynamically at run time. The algorithm schedules lower frequency operators at earlier steps and higher frequency operators to later steps. This algorithm assigned the frequency for each execution cycle then it adjusted the voltage associated with the frequency.

  • PDF

Low Outliers를 고려한 홍수빈도분석에 관한 연구 (A study on the Flood Frequency Analyzed in Consideration of Low Outliers.)

  • 이순혁;홍성표;박명근
    • 한국농공학회지
    • /
    • 제30권4호
    • /
    • pp.62-70
    • /
    • 1988
  • This study was conducted to solve the problems for the unsuitable parameters and the uncertainty of design flood can be appeared by low outliers were inclined to the lower part from the trend of the balance of the data. Derivation of reasonable design flood was attempted finally by modification of low outliers with analysis of flood frequency by means of Log Pearson Type Ill distribution. Three subwatersheds were selected as studying basins with the annual maximum series including low outliers along Geum River basin. The results through this study were analyzed and summarized as follows. 1. Log Pearson Type In distribution was confirmed as a reasonable one by X$^2$ goodness of fit test at Gong Ju, Gyu Am, og Cheon watershed along Geum River basin. 2. Probable flood flows for each watershed were derivated by flood frequency curve with outliers. 3. Weighted skew coefficient for each watershed was calculated for the evaluation of freq- uency factor which is needed for the modification of low outlier. 4. It was confirrned that adjusted frequency curve has a lower tendency than that of deletion of low outlier in common at all watersheds. 5. Final probable flood flows were derivated by modification with evaluation of modified basic statistics for three watersheds. 6. In comparison with a frequency curve with modification and one with outlier, The former has a higher probable flood flow within three years of return periods than that of the latter, and vice versa over three years of return periods.

  • PDF

외이경혈 미세전류신경근 자극과 체성경혈 미세전류신경근 자극이 압통역치에 미치는 효과 (Effects of Microcurrent Electrical Neuromuscular Stimulation of Auricular and Somatic Acupuncture Points on Experimental Pressure Threshold)

  • 고현철;조원호;한승수
    • 한국전문물리치료학회지
    • /
    • 제4권2호
    • /
    • pp.36-50
    • /
    • 1997
  • The purpose of this study was to compare the effects of high intensity, high frequency microcurrent electrical neuromuscular stimulation(MENS) of auricular and somatic acupuncture points and low intensity, low frequency microcurrent electrical neuromuscular stimulation(MENS) of auricular and somatic acupuncture points on experimental pressure threshold at the elbow according to the time. Fifty healthy adults, aged 19 to 26 years, were assigned randomly to one of five groups: 1) the high intensity, high frequency somatic group(n=10) received MENS to somatic acupuncture points, 2) the high intensity, high frequency auricular group(n=10) received MENS to auricular acupuncture points, 3) the low intensity, low frequency somatic group(n=10) received MENS to somatic acupuncture points, 4) the low intensity, low frequency somatic group(n=10) receive MENS to somatic acupuncture points, and 5) the placebo group(n=10) received placebo treatment and served as controls. Pressure threshold was measured before, after, 5 minutes, 10 minutes and 15 minutes. Pressure threshold has increased significantly(p<.05) in the high intensity, high frequency auricular group following treatment after 5 minutes, with no statistically significant differences in pressure threshold change scores among five groups, Only the high intensity, high frequency auricular group demonstrated statistically significant change score in pressure threshold following treatment after, 5 minutes, 10 minutes and 15 minutes after compared to the placebo group. The results indicated that MENS applied to the high intensity, high frequency auricular group increases pressure threshold.

  • PDF

해계 유침 및 전침의 전.후 처치가 실험적으로 항진된 흰쥐의 장운동에 미치는 영향 (The Effect of Acupuncture and Electro-acupuncture of Low and High Frequencies at $ST_{41}$ on Experimentally Induced Intestinal Hypermotility in Rats: Comparison between Pre-treatment and Post-treatment)

  • 최주영;이현
    • Journal of Acupuncture Research
    • /
    • 제27권3호
    • /
    • pp.117-126
    • /
    • 2010
  • Objectives : The purpose of this study was to compare the effect of needle retention(NR) and electro-acupuncture of low(EA(L)) and high(EA(H)) frequencies at Haegye($ST_{41}$) on intestinal hypermotility induced with carbachol in rats Methods : We made over-activated state of intestinal motility with carbachol in rats and caried out needle retention acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture at Haegye($ST_{41}$) or sham point in rat devided into pre-treatment group and post-treatment group. And we resulted as followings from measuring charcoal travel rate with observation of intestinal motility. Results : 1. None of acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture at $ST_{41}$ had significant influences on intestinal motility of rat in normal state. 2. Pre-treated with acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture and post-treated with acupuncture and low frequency electro-acupuncture at $ST_{41}$ didn't significantly influences intestinal motility in rat which over-activated with carbachol. 3. Post-treated with high frequency electro-acupuncture at $ST_{41}$ suppressed intestinal motility in rat which over-activated with carbachol. Conclusions : These results suggest that treatment high frequency electro-acupuncture at ST41 may be effective on gastric disorders such as intestinal hypermotility and its effect had more cure than prevention.