• 제목/요약/키워드: Low flow oxygen

검색결과 250건 처리시간 0.032초

Indium Tin Oxide(ITO) Thin Film Deposition on Polyethylene Terephthalate(PET) Using Ion Beam Assisted Deposition(IBAD)

  • Bae, J.W.;Kim, H.J.;Kim, J.S.;Lee, Y.H.;Lee, N.E.;Yeom, G.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.81-83
    • /
    • 2000
  • Tin-doped indium oxide(ITO) thin films were deposited on polyethylene terephthalate(PET) at room temperature by oxygen ion beam assisted evaporator system and the effects of oxygen gas flow rate on the properties of room temperature ITO thin films were investigated. Plasma characteristics of the ion gun such as oxygen ions and atomic oxygen radicals as a function of oxygen flow rate were investigated using optical emission spectroscopy(OES). Faraday cup also used to measure oxygen ion density. The increase of oxygen flow rate to the ion gun generally increase the optical transmittance of the deposited ITO up to 6sccm of $O_2$ and the further increase of oxygen flow rate appears to saturate the optical transmittance. In the case of electrical property, the resistivity showed a minimum at 6 sccm of $O_2$ with the increase of oxygen flow rate. Therefore, the improved ITO properties at 6 sccm of $O_2$ appear to be more related to the incorporation of low energy oxygen radicals to deposited ITO film rather than the irradiation of high energy oxygen ions to the substrate. At an optimal deposition condition, ITO thin films deposited on PET substrates showed the resistivity of $6.6{\times}10^{-4}$ ${\Omega}$ cm and optical transmittance of above 90%.

  • PDF

가정용 산소발생기를 위한 스월링 유동을 이용한 고성능 흡기 소음기 개발 (Development of High Performance Intake Silencer Using Swirling Flow for Household Oxygen Generators)

  • 김성훈;이광세;최용복;정철웅
    • 한국소음진동공학회논문집
    • /
    • 제24권11호
    • /
    • pp.846-853
    • /
    • 2014
  • High performance intake silencer with low pressure drop are developed for a household oxygen generator. First, the acoustic power of the target oxygen generator are experimentally evaluated according to ISO code. Then, the transmission loss of and the flow characteristics inside the existing intake silencer are predicted and analyzed. On a basis of these results, two intake silencers are proposed, which are designed to induce the swirling flow inside the intake silencer and thus to reduce the flow loss. The predicted TL and the pressure drop for these two new silencers are compared to the existing one, which shows that the proposed ones have higher TL as well as low pressure drop. The reason for these improvements are explained by investigating the flow characteristics of the new silencers in detail.

진동만의 빈산소수괴 형성기구 (Mechanism of Oxygen-Deficient Water Formation in Jindong Bay)

  • 김동선;김상우
    • 한국해양학회지:바다
    • /
    • 제8권2호
    • /
    • pp.177-186
    • /
    • 2003
  • 하계 진동만 저층수의 저산소화에 미치는 성층 및 바람의 효과를 고려한 수평 및연직 유동성분의 영향을 조사하여 내만역에서의 빈산소수괴 형성기구를 밝혔다. 진동만에서 수온, 염분, 용존산소 및 풍향, 풍속은 1998년 3월부터 1999년 2월 사이에 조사하였다 저층수에서 5 이하의 낮은 용존산소농도가 5월에서 9월에 걸쳐 존재하였으며, 표층수의 고온·저염화에 따라 강한 약층이 형성되어 연직기울기는 매우 크게 나타난 하계(7∼8월)에 3 이하의 극히 낮은 용존산소농도가 출현하였다. 이와 같은 저농도의 용존산소는 특히 만 안쪽 정점에서 춘계(5∼6월)에도 관찰되었다. 또한, 하계(8∼9월)에 5 이하의 낮은 용존산소농도를 가지는 저층수가 약 4∼6 m 수층까지 표층쪽으로 부상하는 특징적인 현상이 나타났다 여름철 진동만에서 바람의 효과를 고려한 잔차류의 연직성분을 살펴보면, 이 지역에서 우세한 북풍이나 서풍계열의 바람에 의해서 만 바깥쪽을 하강류역이, 만 안쪽은 상승류역이 발생한다. 또한, 하강류역인 만 바깥쪽에서 만 안쪽으로 향하는 저층류가 발달하였는데, 이것은 표층으로부터 침강된 유기물질의 만 안쪽으로의 유입을 초래할 수 있을 것으로 기대된다. 한편 말 안쪽에서 나타나는 상승류의 존재가 만 안쪽에서 형성된 저층의 빈산소수를 표층 근처까지 부상하게 하는 역할을 하는 것으로 보인다.

DC Magnetron Sputtering에 의한 ATO 박막의 제조 (I)증착특성 (Preparation of ATO Thin Films by DC Magnetron Sputtering (I) Deposition Characteristics)

  • 윤천;이혜용;정윤중
    • 한국세라믹학회지
    • /
    • 제33권4호
    • /
    • pp.441-447
    • /
    • 1996
  • Sb doped SnO2(ATO:Antinomy doped Tin Oxide) thin films were prepared by a DC magnetron spttuering method using oxide target and the deposition characteristics were investigated. The experimental conditions are as follows :Ar flow rate : 100 sccm oxygen flow rates ; 0-100 sccm deposition temperature ; 250 -40$0^{\circ}C$ DC sputter powder ; 150~550 W and sputtering pressure ; ; 2~7 mTorr. Deposition rate greatly depends not on the deposition temperature but on the reaction pressure oxygen flow rate and sputter power,. when the sputter powder is low ATO thin films with (110) preferred orientation are deposited. And when the sputter power is high (110) prefered orientation appeares with decreasing of oxygen flow rate and increasing of suputte-ring pressure.

  • PDF

탄소주입 실리콘 산화막 위에 성장한 투명전극 ZnO 박막의 광학적 특성 (Optical Properties of Transparent Electrode ZnO Thin Film Grown on Carbon Doped Silicon Oxide Film)

  • 오데레사
    • 반도체디스플레이기술학회지
    • /
    • 제11권2호
    • /
    • pp.13-16
    • /
    • 2012
  • Zinc oxide (ZnO) films were deposited by an RF magnetron sputtering system with the RF power of 200W and 300W and flow rate of oxygen gases of 20 and 30 sccm, in order to research the growth of ZnO on carbon doped silicon oxide (SiOC) thin film. The reflectance of SiOC film on Si film deposited by the sputtering decreased with increasing the oxygen flow rate in the range of long wavelength. In comparison between ZnO/Si and ZnO/SiOC/Si thin film, the reflectance of ZnO/SiOC/Si film was inversed that of ZnO/Si film in the rage of 200~1000 nm. The transmittance of ZnO film increased with increasing the oxygen gas flow rate because of the transition from conduction band to oxygen interstitial band due to the oxygen interstitial (Oi) sites. The low reflectance and the high transmittance of ZnO film was suitable properties to use for the front electrode in the display or solar cell.

High-flow nasal cannula oxygen therapy in children: a clinical review

  • Kwon, Ji-Won
    • Clinical and Experimental Pediatrics
    • /
    • 제63권1호
    • /
    • pp.3-7
    • /
    • 2020
  • High-flow nasal cannula (HFNC) is a relatively safe and effective noninvasive ventilation method that was recently accepted as a treatment option for acute respiratory support before endotracheal intubation or invasive ventilation. The action mechanism of HFNC includes a decrease in nasopharyngeal resistance, washout of dead space, reduction in inflow of ambient air, and an increase in airway pressure. In preterm infants, HFNC can be used to prevent reintubation and initial noninvasive respiratory support after birth. In children, flow level adjustments are crucial considering their maximal efficacy and complications. Randomized controlled studies suggest that HFNC can be used in cases of moderate to severe bronchiolitis upon initial low-flow oxygen failure. HFNC can also reduce intubation and mechanical ventilation in children with respiratory failure. Several observational studies have shown that HFNC can be beneficial in acute asthma and other respiratory distress. Multicenter randomized studies are warranted to determine the feasibility and adherence of HFNC and continuous positive airway pressure in pediatric intensive care units. The development of clinical guidelines for HFNC, including flow settings, indications, and contraindications, device management, efficacy identification, and safety issues are needed, particularly in children.

구역용융법으로 제작된 NdBaCuO 초전도체의 산소흡착 특성 (Oxygenation of Zone-melting NbBaCuO superconductor)

  • Soh, Dea-Wha;Fan, Zhanguo;Kim, Hee-Nam;Li, Xinyu;Gao, Weiying;Kim, Tae-Wan
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.292-295
    • /
    • 2001
  • The NdBaCuO superconducting samples were prepared by the Zone melting under low oxygen partial pressure. After the zone-melting the oxygenation process of the NdBaCuO samples in a oxygen flow furnace was studied. In order to compare the oxygenation condition the sintering NdBaCuO samples were studied also. In the study it is found that the optimum temperature for the oxygenation is $350^{\circ}C$, and the oxygen flow speed, the sample volume and the surface area of the sample would influence the oxygenation and the oxygen content.

  • PDF

구역용융법으로 제작된 NdBaCuG 초전도체의 산소흡착 특성 (Oxygenation of Zone-melting NdBaCuG Superconductor)

  • Soh, Dea-Wha;Fan, Zhanguo;Kim, Hee-Nam;Li, Xinyu;Gao, Weiying;Kim, Tae-Wan
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.292-295
    • /
    • 2001
  • The NdBaCuO superconducting samples were prepared by the Zone melting under low oxygen partial pressure. After the zone-melting the oxygenation process of the NdBaCuO samples in a oxygen flow furnace was studied. In order to compare the oxygenation condition the sintering NdBaCuO samples were studied also. In the study it is found that the optimum temperature for the oxygenation is $350{\circ}C$, and the oxygen flow speed, the sample volume and the surface area of the sample would if1uence the oxygenation and the oxygen content.

  • PDF

극저온 자연순환회로의 가속 및 저중력 구간 유량 분석 (Analysis of the Flow Rate for a Natural Cryogenic Circulation Loop during Acceleration and Low-gravity Section)

  • 백승환;정영석;조기주
    • 한국추진공학회지
    • /
    • 제23권5호
    • /
    • pp.43-52
    • /
    • 2019
  • 극저온 유체를 사용하는 발사체는 극저온 유체의 자연순환회로를 이용하여 발사체의 엔진 입구를 냉각한다. 자연순환회로의 질량유량은 순환시스템을 구성하는 배관의 길이 및 직경과 시스템으로 들어오는 열유입에 의하여 결정된다. 극저온 유체의 자연순환회로의 순환 검증 및 질량유량 측정을 위하여 실험을 진행하였으며, 이론적 계산 결과와 비교하였다. 비교 결과 12%의 오차가 있음을 확인하였다. 이 결과를 바탕으로 발사체 상단에서 저중력 구간 및 가속 구간에서의 자연순환 질량유량을 예측한 내용을 포함한다. 가속구간에서는 산화제탱크가 100 kPa 내외로 유지하는 것이 자연순환유량 증가에 이로웠으며, 저중력구간에서는 중력가속도의 크기에 따른 최적 압력으로 조절해야 자연순환유량의 최고값을 유지할 수 있었다.

재택산소요법을 받고 있는 환자들에 대한 임상 관찰 (Clinical Experience of Long-term Home Oxygen Therapy)

  • 이영석;차승익;한춘덕;김창호;김연재;박재용;정태훈
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권3호
    • /
    • pp.283-291
    • /
    • 1993
  • 연구배경 : 장기간의 저농도 산소요법은 저산소혈증을 가진 만성폐쇄성폐질환 환자들의 생존율을 향상시킬 뿐만 아니라 삶의 질을 향상시킨다. 저자들은 재택산소요법을 시행하는 환자의 실태를 알아보고 효과적인 개선책을 알아보기 위하여 추적관찰중인 환자 26예에 대한 임상적 관찰을 하였다. 방법 : 대상환자는 경북대학병원 호흡기내과에서 진료를 받고 있는 환자 가운데 가정에서 장기간의 저농도 산소요법을 시행하고 있는 남자 18명 여자 8명 이었으며 재택산소요법을 시행하기전에 신체적 특성과 병력, 폐기능검사, 심전도, 동맥혈가스 및 말초 혈액검사 소견들과 사용중인 산소용기의 종류, 하루에 흡입하는 시간, 투여산소의 농도, 그리고 사용기간 및 문제점 등에 대해서 조사하였다. 결과 : 원인질환은 만성폐쇄성폐질환 14예, 중증폐결핵의 후유증 9예, 기관지확장증 2예 그리고 특발성 폐섬유증 1예였다. 산소치료의 시행동기는 폐성심이 21예, 운동시 호흡곤란 및 심한 환기장애 4예, 그리고 수면중 산소포화도가 90%미만인 경우가 1예였다. 치료시작전의 동맥혈가스소견의 평균치는 $PaO_2$ 57.7 mmHg, $PaCO_2$ 48.2 mmHg 및 $SaO_2$ 87.7% 였으며 폐활량의 평균치는 VC 2.05 L, $FEV_1$ 0.92 L, $FEV_1$/FVC% 51.9%였다. 사용중인 산소용기는 산소탱크를 사용하는 경우가 19예, 산소농축기를 사용하는 경우가 1예, 산소탱크와 액화산소를 함께 사용하는 경우가 2예, 그리고 산소탱크와 휴대용산소를 함께 사용하는 경우 4예였다. 산소사용 기간은 1년 미만이 3예, 1년에서 2년이 15예, 3년에서 5년이 6예 그리고 9년, 10년 동안 산소요법을 시행한 경우도 각각 1예씩 있었다. 산소농도는 전예에서 2.5L/min 이하를 사용하고 있었고 하루 사용시간은 10예 만이 15시간 이상을 사용하였고 대부분이 짧은 시간 동안만 산소를 사용하고 있었다. 결론 : 효과적인 산소투여를 위해서는 환자 및 주위의 사람들에게 장기간의 저농도 산소요법에 대한 교육이 필요하며 편리하게 사용할 수 있는 산소용기의 구입을 위한 제도적 뒷받침이 필요하다.

  • PDF