• Title/Summary/Keyword: Low energy building

Search Result 542, Processing Time 0.027 seconds

Manufacturing properties of γ-dicalcium silicate with synthetic method

  • Chen, Zheng-xin;Lee, Han-seung;Cho, Hyeong-Kyu
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.spc1
    • /
    • pp.109-112
    • /
    • 2019
  • γ-dicalcium silicate(γ-C2S) is known as a polymorphism of belite. Due to its high CO2 fixed capacity and the low CO2 emission production process, γ-C2S has attracted more and more attention of researchers. For the further development of application of γ-C2S in building construction industry. In this study, we aim to investigate the method for synthesizing high purity of γ-C2S. The influence of different raw materials and calcination temperatures on the purity of γ-C2S was also evaluated. Several Ca bearing materials were selected as the calcium source, the materials which' s main component is SiO2 were used as the silicon source. Raw materials were mixed and were calcined under different temperatures. The results reveal that the highest purity could be obtained using Ca(OH)2 and SiO2 powder as raw materials. And for the practical application, a relatively economic synthesis method using natural mineral materials- limestone and silica sand as raw materials was developed, by this method, the purity of the synthetic γ-C2S was 77.6%.

Effect of Stirrup Spacing of Columns and an Additional Wall other than Core Walls on the Seismic Performance of Piloti-type Buildings (코어 외 추가 벽체와 기둥 띠철근 간격이 필로티 건물의 내진성능에 미치는 영향)

  • Lee, Soo Jeong;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.171-181
    • /
    • 2024
  • For low-rise piloti-type buildings that suffered significant damage in the Pohang earthquake, the seismic performance of those designed by codes issued before and after the earthquake has been recently revised. This study started with the expectation that many of the requirements presented in the current codes may be excessive, and among them, the spacing of column stirrup could be relaxed. In particular, the recently revised design code of concrete structures for buildings, KDS 41 20 00, suggests that the column stirrup spacing is 1/2 of the minimum cross-sectional size or 200 mm, which is strengthened compared to KBC 2016, but relaxed than the current KDS, 41 17 00, which is 1/4 of the minimum size or 150 mm. As a result of the study, it was found that the target performance level was sufficiently satisfied by following the current standards and that it could be satisfied even if the relaxed spacing was followed. Therefore, the strict column stirrup spacing of KDS 41 17 00 could be relaxed if a wall other than core walls is recommended in the current guideline for the structural design of piloti-type buildings.

Some Issues on the International Regulations Associated with the Air Pollution Caused by the SOx Emission at Sea (해양에서 황산화물 오염 규제에 대한 소고)

  • Lee, G.H.;Song, Mu-Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.4
    • /
    • pp.221-226
    • /
    • 2008
  • Air pollution associated with the SOx emission from the shipboard propulsion and generation engines is becoming one of the major environmental concerns these days. Lead by the international organizations including IMO and European Union, a significantly strengthened air pollution related regulations have been introduced and they are becoming in practice as scheduled. Such rules are basically giving the guidelines for permissible SOx emission which can be only met by using high quality fuel oils with less sulfur content or operating scrubbing systems aiming at reducing SOx at the engine exhaust. Since both countermeasures can lead to the cost increase in ship building and operation, Korean shipbuilding industries, leading the world's market, need to be well aware of the ever changing regulations and be prepared with proper solutions. Here, we briefly summarize such latest rules and regulations on the air pollution at sea, and review some technical issues on the scrubbing systems available with some suggestions.

  • PDF

Behavior of dry medium and loose sand-foundation system acted upon by impact loads

  • Ali, Adnan F.;Fattah, Mohammed Y.;Ahmed, Balqees A.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.6
    • /
    • pp.703-721
    • /
    • 2017
  • The experimental study of the behavior of dry medium and loose sandy soil under the action of a single impulsive load is carried out. Different falling masses from different heights were conducted using the falling weight deflectometer (FWD) to provide the single pulse energy. The responses of soils were evaluated at different locations (vertically below the impact plate and horizontally away from it). These responses include; displacements, velocities, and accelerations that are developed due to the impact acting at top and different depth ratios within the soil using the falling weight deflectometer (FWD) and accelerometers (ARH-500A Waterproof, and Low capacity Acceleration Transducer) that are embedded in the soil and then recorded using the multi-recorder TMR-200. The behavior of medium and loose sandy soil was evaluated with different parameters, these are; footing embedment, depth ratios (D/B), diameter of the impact plate (B), and the applied energy. It was found that increasing footing embedment depth results in: amplitude of the force-time history increases by about 10-30%. due to increase in the degree of confinement with the increasing in the embedment, the displacement response of the soil will decrease by about 25-35% for loose sand, 35-40% for medium sand due to increase in the overburden pressure when the embedment depth increased. For surface foundation, the foundation is free to oscillate in vertical, horizontal and rocking modes. But, when embedding a footing, the surrounding soil restricts oscillation due to confinement which leads to increasing the natural frequency, moreover, soil density increases with depth because of compaction, that is, tendency to behave as a solid medium.

A Study on Application Analysis Using RETRAN Computer Code for the Environmental Qualification Flood Analysis Following the Main Feed Water Line Break (주급수관 파단에 따른 내환경검증 침수분석용 전산코드 RETRAN의 적용 해석연구)

  • Park, Young-Chan;Cho, Cheon-Hwey;Hong, Sung-In
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.103-112
    • /
    • 2007
  • Flood issue for nuclear power plants designed and built in 1970 is extremely severe for main steam header compartment and main feedwater line region of intermediate building and lower floor. A calculation for flood level at the main feedwater line isolation compartment is now performing by hand calculation. But, this methodology is quite conservative assumption. The goal of this study was to develop method to analyze flowrate using the RETRAN-3D computer code, and the developed method was applied to flood level analysis following main feedwater line break. As a result of analysis, flood level was low remarkably.

A Study on the Change of Indoor Thermal Environment According to the location of Blinds (블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구)

  • Hwang, Deuk-Soo;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.

Establishment of Climate Region by Recent 30-year Temperature Range in South Korea Area (남한지역의 최근 30년간 기온분포에 의한 기후권역 설정)

  • Ryu, Yeon-Soo;Park, Mi-Lan;Kim, Jin-Wook;Joo, Hye-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.376-382
    • /
    • 2011
  • Since the Industrial Revolution has caused global change by using of a fossil fuel, a reckless and growth-oriented development. A global mean temperature since 19th century has climbed up 0.4~$0.8^{\circ}C$. Our country, afterwards, global warming has increased the temperature every season. After The Kyoto Protocol regarding a greenhouse gas reduction goal took effect, be situations that decrease of greenhouse gas was acutely required. Therefore, interest of utilization of the new & renewable energy is increasing everyday. In advanced research, we shows that at first divided a country to nine range by natural geography, and second executed Meteorological data analysis of recent 30 years considering level of significance by nine range. The results of advanced research are that the similarities are low because there are the regions that temperature deviation of the similar climate regions is large in winter season, and there are not characteristics of clear discrimination of temperature. This study shows that at first divided a country to six range by temperature range, and second executed Meteorological data analysis of recent 30 years considering level of significance by six range. The results of this study are that in heating load calculation of building, periodic temperature data management is required because facility capacity and cost are affected greatly by outdoor temperature, and temperature by climate range needs consideration of pertinent area. Ground temperature was assumed of the weather in region, the ground and soil. Lastly, we were able to know that establishment of climate region by temperature range can be useful policy making and plans of design of the horticultural facilities and architectures.

  • PDF

A Study on the Passive House Technology Application of University Dormitory through The House at Cornell Tech (코넬 공과대학 기숙사 사례를 통한 대학 기숙사의 패시브 하우스 기술 적용에 관한 연구)

  • Kim, Hong-Min;Oh, Hyoung-Seok;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.4
    • /
    • pp.11-18
    • /
    • 2018
  • Global warming is happening now and inevitable. Everyone knows that immediate action should be taken to slow it down, but uncertain about the effective solution. Despite global efforts to reduce greenhouse gas emissions, sea levels are rising gradually. In 2013, Cornell University announced the Climate Action Plan(CAP) to make the campus greener, to reduce waste, and to ensure efficient use of resources. In particular, they set a goal of reducing energy use by 2050 and making carbon emissions to zero. Accordingly, the purpose of this study is to analyse the case of the master plan of Cornell Tech campus and its major buildings. Mainly, The House, faculty and student housing of Cornell Tech and the world tallest certified passive house, will be the main precedent that shows the architectural planning of passive house. Passive house technology, which was thought to be possible only in single-family houses, can be applied to high-rise buildings. If any passive house technology of The House project is actively introduced into the dormitory projects of domestic universities that are about to be built or renovated, it will be a good opportunity for the university to take the lead in preparing for global warming.

Observation and Analysis of Long and Short-wave Radiation According to Types of Summer Shelters (하계 그늘쉼터 유형별 장·단파복사 관측과 해석)

  • Baek, Chang-Hyeon;Choi, Dong-Ho;Lee, Bu-Yong;Lee, In-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.127-135
    • /
    • 2019
  • In this study, we analyzed the relationship between five factors: long-wave radiation, short-wave radiation, cloudiness, SVF and summer shelters. In the previous study, we recognized the correlation between single building SVF and long-wave radiation. Furthermore, this study attempted to confirm the relationship at the summer shelter with high solar radiation blocking rate. The observations are as follows. ① Cooling in summer shelters was not the effect of temperature but the effect of radiation reduction due to short-wave radiation shielding. ② In the case of the canopy tent with low heat capacity, the long-wave radiation was observed to be 16.7% higher per hour than the comparison control point due to the increase in surface temperature. ③ The long-wave radiation increase rate was different according to SVF, but showed very similar pattern according to the material characteristics of the summer shelters. ④ Passive Cooling effect on the type of summer shelters are determined by the size of the total long and short-wave radiation at that point.

A Study on Encryption Module for Remote Terminal Security of Smart Water-Grid Network (스마트 워터그리드 네트워크의 원격 단말기 보안을 위한 암호화 모듈에 관한 연구)

  • Park, Seung-Hwan;Park, Hyung-Mo;Kim, Chang-Bok
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.712-719
    • /
    • 2013
  • This paper studies the security module for the reliable transmission of the meter reading and the control data between the remote terminals and the upper server-side in smart water grid. The proposed security module was implemented to make it attachable to the remote terminal without security function. In particular, unlike the smart grid of electric field, the low power is considered due to the use of battery power in the smart water grid, and the ARIA-GCM-128 symmetric key method is adopted taking into the account that the damp and constrictive environments by the installed meter location in the underground occur a communication obstacle on building of the large-scale network system. The encryption module of this paper was devised to ensure the safety between the reading data on the terminal and the control data from the upper server, and secure the stability of the remote meter reading system by taking protection against an arbitrary alteration or modification.