• Title/Summary/Keyword: Low O/F Ratio

Search Result 114, Processing Time 0.024 seconds

The effects of LEDs and duty ratio on the growth and physiological responses of Silene capitata Kom., endangered plant, in a plant factory

  • Park, Jae-Hoon;Lee, Eung-Pill;Han, Young-Sub;Lee, Soo-In;Cho, Kyu-Tae;Hong, Yong-Sik;You, Young-Han
    • Journal of Ecology and Environment
    • /
    • v.42 no.4
    • /
    • pp.174-182
    • /
    • 2018
  • Background: In this study, we observed their growth and physiological responses using a variety of duty ratio under the mixed light using red, blue, and white lights. The red+blue mixed light was treated with 95%, 90%, 85%, 80%, and 75% duty ratios and red+blue+white mixed light with 85% and 70% duty ratios. We examined the width and length of leaves, total number of leaves, and number of shoots to examine their growth responses. The physiological responses were studied by measuring their photosynthetic rate, transpiration rate, stomatal conductance, water use efficiency, chlorophyll content, and fluorescence ($F_o$, $F_m$, and $F_v/F_m$). Results: We found that lower duty ratio caused the length and width of the leaves to grow longer under red+blue mixed light but that it did not cause any difference in the red+blue+white mixed light condition. In addition, there was no difference in the number of leaves and shoots among all treatments. In the red+blue mixed light condition, the photosynthetic rate was no difference, but both transpiration rate and stomatal conductance were the highest at 95% duty ratio than in other ratios. Water use efficiency pattern was similar to that of photosynthetic rate; water use efficiency was no difference. Chlorophyll content was the highest at 95% duty ratios, and it was the least at 90%, 85%, and 75% duty ratio. $F_o$ and $F_m$ values were relatively high at 85% and 80% duty ratio and low at 90% duty ratio while $F_v/F_m$ showed no difference. Conclusions: Under the red+blue+white mixed light, all physiological items showed no difference between 70 and 85% treatments. But, photosynthetic rate, water use efficiency, chlorophyll content, and $F_v/F_m$ were relatively greater in the red+blue+white mixed light than in the red+blue mixed light. Therefore, red+blue+white mixed light treated with 70% duty ratio could lessen the environmental stress and save more power when cultivating Silene capitata in a plant factory.

Fabrication of Low Temperature Cofiring Substrate Containing Fluorine by Water Swelling (Water Swelling을 이용한 Fluorine함유 저온소결 기판의 제조)

  • 윤영진;최정헌;이용수;강원호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.2
    • /
    • pp.19-25
    • /
    • 2002
  • Glass composed of $Li_2$O.MgO. $MgF_2$.$SiO_2$.$B_2O_3$ for the fabrication of green sheet was prepared by melting process, and glass ceramics was prepared by the process of nucleation and grystal growth for the glass of $Li_2$O.MgO. $MgF_2$.$SiO_2$.$B_2O_3$ system with Lithium fluorhectorite and Lithium boron fluorphlogopite crystal phase. Powderization of the glass ceramics was carried out by water swelling. The average particle size at this point was 2.574 $\mu\textrm{m}$. Slurry was prepared for green sheet using high viscous sol fabricated by water swelling, which shows cleavage phenomenon in prepared glass ceramics. The optimum ratio of powder to water for the tape casting was 18:100, and its viscosity was 11,000~14,000 cps.

  • PDF

Characterization of Fluorocarbon Thin Films deposited by PECVD (PECVD로 증착된 불화 유기박막의 특성 평가)

  • 김준성;김태곤;박진구;신형재
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.2
    • /
    • pp.31-36
    • /
    • 2001
  • Teflon-like fluorocarbon thin film was deposited by using difluoromethane$(CH_2F_2$) added with Ar, $O_2$, and $CH_4$ on Si, $SiO_2$, TEOS, and Al substrate. The deposited thin film was characterized by static contact angles for measuring hydrophobicity in various additive gas ratio. temperature, and working pressure. In case of addition with Ar, the static contact angles decreased as additive gas ratio and power increased. But the static contact angles increased as working pressure increased. Specially, super-hydrophobic surface was obtained using the powder-like fluorocarbon thin film above 2 Torr. Added with $O_2$, the static contact angles decreased as the $O_2$ ratio and working pressure increased. And the static contact angles did not change in 100W, but hydrophilic surface was obtained at 200W. In case of addition of CE$_4$, static contact angles dramatically increased in $CH_4/CH_2F_2$ ratio 5. And continuous static contact angles obtained above ratio 5. As compare with previous experiments by thermal evaporation, the fluorocarbon thin film by plasma polymerization was obtained very low hysteresis. This results shows more homogenous surface by plasma polymerization than thermal evaporation process.

  • PDF

Decrease of Global Warming Effect During Dry Etching of Silicon Nitride Layer Using C3F6O/O2 Chemistries

  • Kim, Il-Jin;Moon, Hock-Key;Lee, Jung-Hun;Jung, Jae-Wook;Cho, Sang-Hyun;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.459-459
    • /
    • 2012
  • Recently, the discharge of global warming gases in dry etching process of TFT-LCD display industry is a serious issue because perfluorocarbon compound (PFC) gas causes global warming effects. PFCs including CF4, C2F6, C3F8, CHF3, NF3 and SF6 are widely used as etching and cleaning gases. In particular, the SF6 gas is chemically stable compounds. However, these gases have large global warming potential (GWP100 = 24,900) and lifetime (3,200). In this work, we chose C3F6O gas which has a very low GWP (GWP100 = <100) and lifetime (< 1) as a replacement gas. This study investigated the effects of the gas flow ratio of C3F6O/O2 and process pressure in dual-frequency capacitively coupled plasma (CCP) etcher on global warming effects. Also, we compared global warming effects of C3F6O gas with those of SF6 gas during dry etching of a patterned positive type photo-resist/silicon nitride/glass substrate. The etch rate measurements and emission of by-products were analyzed by scanning electron Microscopy (SEM; HITACI, S-3500H) and Fourier transform infrared spectroscopy (FT-IR; MIDAC, I2000), respectively. Calculation of MMTCE (million metric ton carbon equivalents) based on the emitted by-products were performed during etching by controlling various process parameters. The evaluation procedure and results will be discussed in detail.

  • PDF

A Study of Deposition Mechanism of Laser CVD SiO2 Film

  • Sung, Yung-Kwon;Song, Jeong-Myeon;Moon, Byung-Moo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.5
    • /
    • pp.33-37
    • /
    • 2003
  • This study was performed to investigate the deposition mechanism of SiO$_2$ by ArF excimer laser(l93nm) CVD with Si$_2$H$\_$6/ and N$_2$O gas mixture and evaluate laser CVD quantitatively by modeling. With ArF excimer laser CVD, thin films can be deposited at low temperature(below 300$^{\circ}C$), with less damage and good uniformity owing to generation of conformal reaction species by singular wavelength of the laser beam. In this study, new model of SiO$_2$ deposition process by laser CVD was introduced and deposition rate was simulated by computer with the basis on this modeling. And simulation results were compared with experimental results measured at various conditions such as reaction gas ratio, chamber pressure, substrate temperature and laser beam intensity.

The Structural and Electrical Properties of Vanadium Oxide Thin Films as $O_2/(Ar+O_{2})$ ratio ($O_2/(Ar+O_{2})$비에 따른 바나듐 산화막의 구조적, 전기적 특성)

  • 최용남;최복길;최창규;김성진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.729-732
    • /
    • 2001
  • In this study, the effect of oxygen partial pressure on the electrical properties of vanadium oxide(VO$_{x}$) thin films were investigated. The thin films were prepared by r.f. magnetron sputtering from V$_2$O$_{5}$ target in a gas mixture of argon and oxygen. The oxygen partial pressure ratio is changed from 0% to 8%. I-V characteristics were distinguished between linear and nonlinear region. In the low field region the conduction is due to Schottky emission, while at high fields it changes to Fowler-Nordheim tunneling type conduction. The conductivity measurements have shown an Arrhenius dependence of the conductivity on the temperature.ure.

  • PDF

Dual-band Predistortion Linear Power Amplifier for Base-station Application (기지국용 이중 대역 전치 왜곡 선형 전력 증폭기)

  • Choi, Heung-Jae;Jeong, Yong-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.10 s.113
    • /
    • pp.959-966
    • /
    • 2006
  • This paper proposes a new concept about dual band predistortion linear power amplifier(PD LPA) using diplexer for digital cellular ($f_o$=880 MHz) and IMT-2000($f_o$=2,140 MHz) base stations. The diplexer is composed of low pass filter having defected ground structure(BGS) microstrip line and high pass filter having high-Q lumped capacitors and distributed elements. The proposed predistorter adopts a reflection type intermodulation signal generator with 3 dB hybrid coupler for good reflection characteristic. for a forward link one carrier CDMA IS-95A 1FA and WCDMA 1FA signal, the proposed dual band PD LPA shows the adjacent channel leakage ratio(ACLR) improvement about 10 dB and 9.36 dB for digital cellular and IMT-2000 band, respectively.

Difference of Short Term Survival in Patients with ARDS According to Responsiveness to Alveolar Recruitment (급성호흡곤란증후군 환자에서 폐포모집술의 반응에 따른 초기 예후의 차이)

  • Kim, Ho Cheol;Cho, Dae Hyun;Kang, Gyoung Woo;Park, Dong Jun;Lee, Jong Deok;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.3
    • /
    • pp.280-288
    • /
    • 2004
  • Background : Lung protective strategies, using low tidal volume in ARDS, improve survival rate in ARDS. However, low tidal volume ventilation may promote alveolar de-recruitment. Therefore, alveolar recruitment is necessary to maintain arterial oxygenation and to prevent repetitive opening and closure of collapsed alveoli in lung protective strategies. There has been a recent report describing improvement in arterial oxygenation with use of recruitment maneuver. However, impact of recruitment on outcome of ARDS is unknown. We evaluated whether short-term survival difference existed in patients with ARDS, who were performed alveolar recruitment maneuver(ARM) and prone position, according to response of alveolar recruitment or not. Methods : All patients who were diagnosed with ADRS and received mechanical ventilation were included. ARM were sustained inflation($35-45cmH_2O$ CPAP for 30-40 sec.) or increasing level of PEEP. If these methods were ineffective, alveolar recruitment with prone position was done for at least 10 hours. $P_aO_2/FiO_2$(P/F) ratio was determined before and at 0.5 and 2 hours after ARM. We defined a responder if the P/F ratio was increased over 50% of baseline value. We compared 10-days and 30-days survival rate between responders and non-responders. Results : 20 patients(M:F=12:8, $63{\pm}14age$) were included. Among them, 12 patients were responders and 8 patients were non-responders. In responders, P/F ratio was increased from $92{\pm}25mmHg$ to $244{\pm}85mmHg$. In non-responders, P/F ratio increased from $138{\pm}37mmHg$ to $163{\pm}60mmHg$. Among non-responders, P/F ratio was improved over 50% in 2 patients after prone position. Overall, 14 patients were responders after ARM and prone position. The 10-days and 30-days survival rate in responders was significantly higher than in non-responders(86%, 57% in responders and 33%, 0% in non-responders)(p<0.05). There was no significant difference between responders and non-responders in age($71{\pm}11$, $60{\pm}14$), lung injury score($2.8{\pm}0.2$, $2.9{\pm}0.45$), simplified acute physiology score(SAPS) II ($35{\pm}4.6$, $34{\pm}5.7$), positive end-positive pressure level($15.6{\pm}1.9cmH_2O$, $14.5{\pm}2.1cmH_2O$). Conclusion : ARM may improve arterial oxygenation in some patients with ARDS. These responders in patients with ARDS showed significant higher 10-days and 30-days survival rate than non-responders patients with alveolar recruitment.

Effect of Low-grade Limestone on Raw Mill Grinding and Cement Clinker Sintering (저품위 석회석이 원료밀의 분쇄성과 시멘트 클링커 소성성에 미치는 영향)

  • Yoo, Dong-Woo;Park, Tae-Gyun;Choi, Sang-Min;Lee, Chang-Hyun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.20-25
    • /
    • 2021
  • The cement clinker, the main raw material of cement, is manufactured using limestone as the main material. Depending on the quality of limestone, the use of subsidiary materials changes, and has a great influence on the production of cement clinkers. In this study, the effect of CaO content of limestone, a cement clinker material, on Raw Mill grinding and sintering of cement clinker was investigated. The grinding time of the union materials changed in the content of limestone CaO was measured to identify the grinding properties. The raw material combination was cleaned within a range of 1,350-1,500℃. The sintering performance of cement clinker by Burnability index calculation was identified. The lower the grade of limestone, the lower the grinding quality of the raw material combination. The lower the CaO content of limestone, the greater the variation in F-CaO for sintering temperature. The lower the class of limestone, the higher B. I. value was calculated, indicating the lower cement clinker sintering. In addition, the mineral analysis results of cement clinker showed that if the F-CaO value was low due to the increase in sintering temperature, the Belite content decreased and the Alite content increased. In the case of Alite, the ratio of R-type decreased and that of M-type increased as the content of limestone CaO increased.

Maintenance of Platelet Counts with Low Level QC Materials and the Change in P-LCR according to Hemolysis with XN-9000 (XN-9000장비에서 Low Level QC물질에서의 혈소판 수 관리와 용혈에 따른 P-LCR의 변화)

  • Shim, Moon-Jung;Lee, Hyun-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.399-405
    • /
    • 2018
  • The platelet count in clinical laboratories is essential for the diagnosis and treatment of hemostasis abnormalities, and accurate platelet counting in the low count range is of prime importance for deciding if a platelet transfusion is needed and for monitoring after chemotherapy. Quality control is designed to reduce and correct any deficiencies in the internal analytical process of a clinical laboratory prior to the release of patient results. Fragmented erythrocytes are the major confusing factors for platelet counting because of their similar size to platelets. The authors found that the low range QC values were out of 2SD with a Sysmex automatic analyzer in internal quality control process. Thus far, there has been little discussion on the relationship between hemolysis and the platelet parameters. Therefore, this study focused on the performance of automated platelet counts, including the PLT-F, the PLT-I, and PLT-O methods at the low platelet range using the low level QC materials and compared the 5 platelet parameters with the hemolyzed samples. The results showed that the CV was the smallest with PLT-F and P-LCR increased from 18.4 to 31.9% in the hemolysis samples. These results indicate that a more accurate estimation of the platelet counts can be achieved using the PLT-F method than the PLT-I method at the low platelet range. The use of the PLT-F system improves the confidence of results in low platelets samples in a routine hematology laboratory. The results suggest that P-LCR is a new parameter in assessing samples when the specimen is suspected of hemolysis and deterioration. Nevertheless, further studies will be needed to establish the relationship with P-LCR and hemolysis using human blood specimens.