• Title/Summary/Keyword: Low Dose Exposure

Search Result 465, Processing Time 0.035 seconds

Gamma Irradiation Effects on Conchospores of Porphyra Species 2. The Effects of High Gamma Irradiation on Germination and Growth of Conchospores of Two Varieties (김의 각포자에 대한 r-선의 조사효과 2. 두 품종의 각포자의 발아생장에 미치는 고선량 r-선의 조사효과)

  • KIM Joong-Rae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.1
    • /
    • pp.52-56
    • /
    • 1985
  • For the fundamental studies of radiation breeding in edible marine algae, the biological effects on conchospores of Porphyra species by gamma-irradiation were examined. Two varieties, Keun-cham-gim (Porphyra tenera Kjell. form tamatsuensis Miura) and Saga No.5, were chosen for this study, and their conchospores after r-irradiation($5.0{\sim}20.0$ KR) were cultured for 50 days. The results obtained were summarized as follows. 1. Gamma-irradiation in less than the dose of 20KR did not affect germination of conchospores, and almost all spores grew into two cells germ in 24 hours after irradiation, but withering germs were gradually increased in number according to higher exposure within 5 days old culture. 2. High irradiation caused the induction of giant cells, abnormal useless growth of hold-fast, lumpish thalli and callus-like lumpy tissues. 3. The liberation of neutral spores from young germs and carpospores from mature thalli were observed on the frond exposed at $10{\sim}20$ KR irradiation. All spores were normal in division and its size. 4. The best irradiation effect on growth of Keun-cham-gim was observed at 10 KR dose, whose growth-rates were $140\%$ in wet weight and $108\%$ in mean frond area, but only $48\%$ was recorded in wet weight at 20 KR exposure. Saga No.5 were in contrast with Keun-cham-gim, and their most growth-rate was $400\%$ in wet weight ($258\%$ in frond area) at 10 KR irradiation and the worst was $20\%$ at the dose of 20 KR. 5. The withering phenomenon to death by treatment of gamma-ray presented substantial difference between two varieties. Survival rate compared with control in Keun-cham-gim was $70.7\%$ at 20 KR, but that in Saga No.5 recorded $47.0\%$ at same dose. 6. Synthesizing the results of high and low r-irradiation, it was suggested tat high r-irradiation in more than 5.0 KR inhibited conspicuously the growth of germs derived from conchospores, and about half of them withered at 15.0 KR dose or more.

  • PDF

The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

CT Examinations for COVID-19: A Systematic Review of Protocols, Radiation Dose, and Numbers Needed to Diagnose and Predict (COVID-19 진단을 위한 CT 검사: 프로토콜, 방사선량에 대한 체계적 문헌고찰 및 진단을 위한 CT 검사량)

  • Jong Hyuk Lee;Hyunsook Hong;Hyungjin Kim;Chang Hyun Lee;Jin Mo Goo;Soon Ho Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1505-1523
    • /
    • 2021
  • Purpose Although chest CT has been discussed as a first-line test for coronavirus disease 2019 (COVID-19), little research has explored the implications of CT exposure in the population. To review chest CT protocols and radiation doses in COVID-19 publications and explore the number needed to diagnose (NND) and the number needed to predict (NNP) if CT is used as a first-line test. Materials and Methods We searched nine highly cited radiology journals to identify studies discussing the CT-based diagnosis of COVID-19 pneumonia. Study-level information on the CT protocol and radiation dose was collected, and the doses were compared with each national diagnostic reference level (DRL). The NND and NNP, which depends on the test positive rate (TPR), were calculated, given a CT sensitivity of 94% (95% confidence interval [CI]: 91%-96%) and specificity of 37% (95% CI: 26%-50%), and applied to the early outbreak in Wuhan, New York, and Italy. Results From 86 studies, the CT protocol and radiation dose were reported in 81 (94.2%) and 17 studies (19.8%), respectively. Low-dose chest CT was used more than twice as often as standard-dose chest CT (39.5% vs.18.6%), while the remaining studies (44.2%) did not provide relevant information. The radiation doses were lower than the national DRLs in 15 of the 17 studies (88.2%) that reported doses. The NND was 3.2 scans (95% CI: 2.2-6.0). The NNPs at TPRs of 50%, 25%, 10%, and 5% were 2.2, 3.6, 8.0, 15.5 scans, respectively. In Wuhan, 35418 (TPR, 58%; 95% CI: 27710-56755) to 44840 (TPR, 38%; 95% CI: 35161-68164) individuals were estimated to have undergone CT examinations to diagnose 17365 patients. During the early surge in New York and Italy, daily NNDs changed up to 5.4 and 10.9 times, respectively, within 10 weeks. Conclusion Low-dose CT protocols were described in less than half of COVID-19 publications, and radiation doses were frequently lacking. The number of populations involved in a first-line diagnostic CT test could vary dynamically according to daily TPR; therefore, caution is required in future planning.

Study on The Technical Improvement in Wireless Power Communication System with Low Power (무선전력통신 시스템의 저전력화를 위한 기술적 개선방안)

  • Chung, Sung-In;Lee, Seung-Min;Lee, Hyo-Sung;Lee, Hug-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.53-57
    • /
    • 2010
  • This study proposes the algorithm which drives the powerless without battery. The exiting wire or RF type dosimeter, which is the computation of the real time with battery on the dose radiation exposure, In the Wired dosimeter, it is trouble to need the maintenance and management by periods. Besides, the case of the RF typed dosimeter with battery, it is requested to size bigger and to replace battery frequently and so on. Especially RF typed dosimeter has trouble to need for the embody with large power consumption on the contactless typed dosimeter. As the method for the low power, the study designed to be down the operating clock of the MPC, to improve the efficiency of the rectifier, to eliminate the external memory and the DC-DC converter for the simplification of the circuit We convince our research contributes not only to understand the simplified circuit and miniaturization, but also to help the design and application technology of the powerless dosimeter.

Study on Electrical Properties of X-ray Sensor Based on CsI:Na-Selenium Film

  • Park Ji-Koon;Kang Sang-Sik;Lee Dong-Gil;Choi Jang-Yong;Kim Jae-Hyung;Nam Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.3
    • /
    • pp.10-14
    • /
    • 2003
  • In this paper, we have introduced the x-ray detector built with a CsI:Na scintillation layer deposited on amorphous selenium. To determine the thickness of the CsI:Na layer, we have estimated the transmission spectra and the absorption of continuous x-rays in diagnostic range by using computer simulation (MCNP 4C). A x-ray detector with 65 ${\mu}m$-CsI:Na/30 ${\mu}m$-Se layer has been fabricated by a thermal evaporation technique. SEM and PL measurements have been performed. The dark current and x-ray sensitivity of the fabricated detector has been compared with that of the conventional a-Se detector with 100 ${\mu}m$ thickness. Experimental results show that both detectors exhibit a similar dark current, which was of a low value below $400 pA/cm^2$ at 10 V/${\mu}m$. However, the CsI:Na-Se detector indicates high x-ray sensitivity, roughly 1.3 times that of a conventional a-Se detector. Furthermore, a CsI:Na-Se detector with an aluminium reflective layer shows a 1.8 times higher x-ray sensitivity than an a-Se detector. The hybrid type detector proposed in this work exhibits a low dark current and high x-ray sensitivity, and, in particular, excellent linearity to the x-ray exposure dose.

Blood Lead Level in Populations Resident in Some Abandoned Mine Area (충청북도 일부 폐광산 지역 주민의 만성 납 노출 정도 평가)

  • Song, Sun-Ho;Eom, Sang-Yong;Kim, Yong-Dae;Kim, Heon;Hong, Jang-Soo
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.527-532
    • /
    • 2010
  • Exposure to lead, particularly at chronic low-dose levels, is still a major public health concern. The present study is aimed to evaluate the blood lead levels in populations resident in some abandoned mine areas of Chungbuk, Korea. Eight hundreds and sixty-six subjects who reside in abandoned mine area located in Chungbuk, Korea, were enrolled this study. We evaluated the blood lead level according to the age, gender, and working history in mines. For statistical analysis, SPSS ver 12.0 was used. The geometric mean blood lead levels was $2.93\;{\mu}g/{\ell}$ and nobody showed levels over the guidelines of WHO. Ex-smokers and current-smokers showed significantly higher blood lead levels compared to that of non-smokers. The blood lead levels in individuals with a history of working in a mine was higher than those in individuals without such histories. The populations resident in some Chungbuk abadoned mine area showed low levels of lead in blood. This suggest that lead poisoning might not be induced by abandoned mine in Chungbuk, Korea.

Apoptosis-Induced Cell Death due to Oleanolic Acid in HaCaT Keratinocyte Cells -a Proof-of-Principle Approach for Chemopreventive Drug Development

  • George, V. Cijo;Kumar, D.R. Naveen;Suresh, P.K.;Kumar, R. Ashok
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2015-2020
    • /
    • 2012
  • Oleanolic acid (OA) is a naturally occurring triterpenoid in food materials and is a component of the leaves and roots of Olea europaea, Viscum album L., Aralia chinensis L. and more than 120 other plant species. There are several reports validating its antitumor activity against different cancer cells apart from its hepatoprotective activity. However, antitumor activity against skin cancer has not beed studied well thus far. Hence the present study of effects of OA against HaCaT (immortalized keratinocyte) cells - a cell-based epithelial model system for toxicity/ethnopharmacology-based studies - was conducted. Radical scavenging activity ($DPPH{\cdot}$) and FRAP were determined spectrophotometrically. Proliferation was assessed by XTT assay at 24, 48 and 72 hrs with exposure to various concentrations (12.5-200 ${\mu}M$) of OA. Apoptotic induction potential of OA was demonstrated using a cellular DNA fragmentation ELISA method. Morphological studies were also carried out to elucidate its antitumor potential. The results revealed that OA induces apoptosis by altering cellular morphology as well as DNA integrity in HaCaT cells in a dose-dependent manner, with comparatively low cytotoxicity. The moderate toxicity observed in HaCaT cells, with induction of apoptosis, possibly suggests greater involvement of programmed-cell death-mediated mechanisms. We conclude that OA has relatively low toxicity and has the potential to induce apoptosis in HaCaT cells and hence provides a substantial and sound scientific basis for further validation studies.

4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanone Induces Retinoic Acid Receptor β Hypermethylation through DNA Methyltransferase 1 Accumulation in Esophageal Squamous Epithelial Cells

  • Wang, Jing;Zhao, Shu-Lei;Li, Yan;Meng, Mei;Qin, Cheng-Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2207-2212
    • /
    • 2012
  • Overexpression of DNA methyltransferase 1 (DNMT1) has been detected in many cancers. Tobacco exposure is known to induce genetic and epigenetic changes in the pathogenesis of malignancy. 4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) is an important carcinogen present in tobacco smoke; however the detailed molecular mechanism of how NNK induces esophageal carcinogenesis is still unclear. We found that DNMT1 was overexpressed in ESCC tissues compared with paired non-cancerous tissues, the overexpression being correlated with smoking status and low expression of $RAR{\beta}$. The latter could be upregulated by NNK treatment in Het-1A cells, and the increased DNMT1 expression level reflected promoter hypermethylation and downregulation of retinoic acid receptor ${\beta}$($RAR{\beta}$). RNA interference mediated knockdown of DNMT1 resulted in promoter demethylation and upregulation of $RAR{\beta}$ in KYSE30 and TE-1 cells. 3-(4,5-Dimethyl-thiazol-2yl)-2,5-diphenyltetrazolium bromide (MTT) and flow cytometric analysis demonstrated that NNK treatment in Het-1A cells could enhance cell proliferation and inhibit cell apoptosis in a dose-dependent manner. In conclusion, DNMT1 overexpression is correlated with smoking status and low expression of $RAR{\beta}$ in esophageal SCC patients. NNK could induce $RAR{\beta}$ promoter hypermethylation through upregulation of DNMT1 in esophageal squamous epithelial cells, finally leading to enhancement of cell proliferation and inhibition of apoptosis.

An Investigation on the Technical Background for Carbon-14 Monitoring in Radioactive Effluents (원자력시설의 Carbon-14 방사성유출물에 대한 감시배경의 조사)

  • Kim, Hee-Geun;Kong, Tae-Young;Jeong, Woo-Tae;Kim, Seok-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.195-200
    • /
    • 2009
  • effluents to the environment. The activity of carbon-14, one of the radioactive effluents, in the environment is already high level and its effect on radiation exposure to the public and the environment is insignificant; thus, NPPs did not perform the carbon-14 monitoring in effluents in the past. By the way, effluents of noble gas and particulate radioactive materials originated from nuclear fuels has been continuously reduced due to both the advancement of manufacturing and integrity technology for nuclear fuels and the improvement of operation methods of NPPs. Futhermore, the portion of dose assessment by tritium and carbon-14 to the public has been relatively increased because the lower limit of detection for low-energy beta sources, such as tritium and carbon-14, is low due to the advancement of radiation detection technology. In this paper, the technical background for carbon-14 monitoring in nuclear facilities was investigated using United States technical reports and papers. This paper also reviews whether carbon-14 monitoring is necessary or not based on the investigated documents.