• Title/Summary/Keyword: Low Dose Exposure

Search Result 475, Processing Time 0.03 seconds

Bioassay in BALB/c mice exposed to low dose rate radiation (저선량율 방사선 조사한 BALB/c 마우스에서의 영향평가)

  • Kim, Sung-Dae;Gong, Eun-Ji;Bae, Min-Ji;Yang, Kwang-Mo;Kim, Joong-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.159-166
    • /
    • 2012
  • The present study was performed to investigate the toxicity of low-dose-rate irradiation in BALB/c mice. Twenty mice of each sex were randomly assigned to four groups of five mice each and were exposed to 0 (sham), 0.02, 0.2, or 2 Gy, equivalents to low-dose-rate irradiation to 3.49 $mGy{\cdot}h^{-1}$. Urine, blood, and blood biochemistry were analyzed, and organ weight was measured. The low-dose-rate irradiation did not induce any toxicologically significant changes in mortality, clinical signs, body weight, food and water consumption, urinalysis, and serum biochemistry. However, the weights of reproductive organs including the testis, ovary, and uterus decreased in a dose-dependent manner. Irradiation at 2 Gy significantly decreased the testis, ovary, and uterus weights, but did not change the weights of other organs. There were no adverse effects on hematology in any irradiated group and only the number of neutrophils increased dose dependently. The low-dose-rate irradiation exposure did not cause adverse effects in mice at dose levels of 2 Gy or less, but the reproductive systems of male and female mice showed toxic effects.

A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter (유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구)

  • Noh, Sung Jin;Kim, Hyo Jin;Kim, Hyun;Jeong, Dong Hyeok;Son, Tae Gen;Kim, Jung Ki;Yang, Kwangmo;Nam, Sang-Hee;Kang, Yeong-Rok
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.202-210
    • /
    • 2015
  • The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using $^{137}Cs$ irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological & Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

Exposure to Ethyl Carbamate by Consumption of Alcoholic Beverages Imported in Korea

  • Hong, Kwon-Pyo;Kang, Yoon-Seok;Jung, Dong-Chae;Park, Sae-Rom;Yoon, Ji-Ho;Lee, Sung-Yong;Ko, Yong-Seok;Kim, So-Hee;Ha, Sang-Do;Park, Sang-Kyu;Bae, Dong-Ho
    • Food Science and Biotechnology
    • /
    • v.16 no.6
    • /
    • pp.975-980
    • /
    • 2007
  • Determination of ethyl carbamate content in imported alcoholic beverages in Korea and an exposure assessment were conducted. In gas chromatography/mass spectrometry/selected ion monitoring (GC/MS/SIM) analysis, 2.5-39, 8-263, 6.3-112, 11.3-23.5, 53-94, 8.5-38.5, 7-9.5, 21.3-31.5, 5-832.5, and $10.5-364.8\;{\mu}g/L$ of ethyl carbamate were detected in imported beers, sakes, whiskies, vodkas, Chinese liquors, cognacs, tequilas, rums, liqueurs, and wines, respectively. The exposure assessment indicated that the exposure of Korean adults to ethyl carbamate were lower than 20 ng/kg BW per day, (the virtual safe dose) indicating that the amount of ethyl carbamate exposed through fermented food and alcoholic beverages including imported products are currently in the 'no significant risk level'. However, the present low exposure to ethyl carbamate through the imported alcoholic products was not due to the low contents of ethyl carbamate in imported products, but low consumption of the imported products. Therefore, given increasing importation of alcoholic beverages in Korea, reductions of ethyl carbamate content in imported alcoholic beverages, especially non-distilled products, should be required by regulating limits on the ethyl carbamate content in the imported alcoholic beverages.

Radiation Biology in Space; DNA Damage and Biological Effects of Space Radiation

  • Ohnishi, Takeo;Takahashi, Akihisa;Ohnishi, Ken
    • Journal of Photoscience
    • /
    • v.9 no.3
    • /
    • pp.37-40
    • /
    • 2002
  • Astronauts are constantly exposed to space radiation at a low-dose rate during long-tenn stays in space. Therefore, it is important to determine correctly the biological effects of space radiation on human health. Space radiations contain various kinds of different energy particles, especially high linear energy transfer (LET) particles. Therefore, we have to study the relative biological effectiveness (RBE) of space radiation under microgravity environment which may change RBE from a stress for cells. Furthermore, the research about space radiation might give us useful information about birth and evolution of life on the earth. We also can realize the importance of preventing the ozone layer from depletion by use of exposure equipment to sunlight at International Space Station (ISS).

  • PDF

Application of Physiologically Based Pharmacokinetic Modeling with Biological Monitoring Data for Risk Assessment (생물학적 모니터링 데이터를 기초한 PBPK 모델의 활용)

  • Yang, Mi-Hi;Yang, Ji-Yeon;Yi, Bit-Na;Lee, Ho-Sun
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.1 s.56
    • /
    • pp.1-8
    • /
    • 2007
  • Biological monitoring, analyses of internal dose for exposure to toxicants, has been thought as one of the belt approaches for risk assessment. As the amount detected in human samples is generally very low, typically in the parts-per-bilion (ppb) or parts-per-trillion (ppt) range, analytic technologies such at HPLC, GC/MS, LC/MS, and LC/MS/MS have been continuously developed. In addition, route specific and sensitive exposure biomarkers have been developed for proper biological monitoring. PBPK modeling, particularly reverse dosimetry, has been emphasized as an useful method via interpretation of biological monitoring results for regulation of toxicants. Thus, this review is focused on the use of PBPK dosimetry models for toxicology research and risk assessment in Korea.

Are dental radiographs dangerous? (치과방사선영상 검사는 위험한 술식인가?)

  • Lee, Byung-Do
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.155-162
    • /
    • 2016
  • Radiographs can help in the diagnosis and treatment planning, but the exposure to ionizing radiation may elevate the risk of developing cancer in a person's lifetime. The objective of this review is to briefly summarize 1) radiation risk, especially cancer risks associated with diagnostic imaging, 2) linear, non-threshold (LNT) hypothesis, 3) the risks of radiation exposure to a fetus, and 4) the campaign of Image Gently. The individual risk of radiation-related cancer from any single medical imaging procedure is extremely small and it is not likely to be cancer risk at doses lower than 100 mGy, but patients may be harmed by avoiding diagnostic imaging due to fear of radiation hazard. Dentists need to understand the radiation doses delivered by various radiographic techniques and the acceptable exposure thresholds to effectively advise the patient and to reduce the unnecessary radiation

  • PDF

Analysis of the minimum exposure position according to the additional filtration plate (부가여과판에 따른 최소한의 피폭 위치에 대한 분석)

  • Tae-Ri, Kim;Min-Ji, Kang;Sang-Hee, La;Yun-Jeong, Shin;Tae-Gyeom, Hong;Min-Cheol, Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.2
    • /
    • pp.11-17
    • /
    • 2022
  • The purpose is to find out where medical workers can receive the minimum radiation does in clinical. In order to sett RQR standard quality of radiation, put a Al 1.5mm filter(row and column: 10 cm × 10 cm) on X-ray tube. Al 0.9 mm, Cu 0.3 mm, Ni 0.3 mm used as a filter. The Acrylic phantom were set to 13.1 cm, 18.5 cm, 21.1 cm. by the object thickness was different. As a results, when we use Al 0.9 mm, 1853 nSv was the highest numeral. It is a point of anode low 50 cm, when we use 13.1 cm Acrylic phantom. When we use Cu 0.3 mm, 173 nSv was the lowest numeral. It is a point of anode low 150 cm, when we use 13.1 cm Acrylic Phantom. In this study, it was confirmed that the spatial scattering dose decreased as the distance from the X-ray tube increased. It is considered that more studies on the exposure of scattered doses are needed in the future.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

Basic Physiological Research on the Wing Flapping of the Sweet Potato Hawkmoth Using Multimedia

  • Nakajima, Isao;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.189-196
    • /
    • 2020
  • We have developed a device for recording biological data by inserting three electrodes and a needle with an angular velocity sensor into the moth for the purpose of measuring the electromyogram of the flapping and the corresponding lift force. With this measurement, it is possible to evaluate the moth-physiological function of moths, and the amount of pesticides that insects are exposed to (currently LD50-based standards), especially the amount of chronic low-concentration exposure, can be reduced the dose. We measured and recorded 2-channel electromyography (EMG) and angular velocity corresponding to pitch angle (pitch-like angle) associated with wing flapping for 100 sweet potato hawkmoths (50 females and 50 males) with the animals suspended and constrained in air. Overall, the angular velocity and amplitude of EMG signals demonstrated high correlation, with a correlation coefficient of R = 0.792. In contrast, the results of analysis performed on the peak-to-peak (PP) EMG intervals, which correspond to the RR intervals of ECG signals, indicated a correlation between ΔF fluctuation and angular velocity of R = 0.379. Thus, the accuracy of the regression curve was relatively poor. Using a DC amplification circuit without capacitive coupling as the EMG amplification circuit, we confirmed that the baseline changes at the gear change point of wing flapping. The following formula gives the lift provided by the wing: angular velocity × thoracic weight - air resistance - (eddy resistance due to turbulence). In future studies, we plan to attach a micro radio transmitter to the moths to gather data on potential energy, kinetic energy, and displacement during free flight for analysis. Such physiological functional evaluations of moths may alleviate damage to insect health due to repeated exposure to multiple agrochemicals and may lead to significant changes in the toxicity standards, which are currently based on LD50 values.

Manganese Distribution in Brains of Sprague Dawley Rats after 60 Days of Stainless Steel Welding-Fume Exposure

  • Yu, Il-Je;Park, Jung-Duck;Park, Eon-Sub;Song, Kyung-Seuk;Han, Kuy-Tae;Han, Jeong-Hee;Chung, Yong-Hyun;Choi, Byung-Sun;Chung, Kyu-Hyuck;Cho, Myung-Haeng
    • Environmental Mutagens and Carcinogens
    • /
    • v.23 no.3
    • /
    • pp.85-93
    • /
    • 2003
  • Welders working in a confined space, like in the shipbuilding industry, are at risk of being exposed to high concentrations of welding fumes and developing pneumoconiosis or other welding-fume exposure related diseases. Among such diseases, manganism resulting from welding-fume exposure remains a controversial issue, as the movement of manganese into specific brain regions has not been clearly established. Accordingly, to investigate the distribution of manganese in the brain after welding-fume exposure, male Sprague Dawley rats were exposed to welding fumes generated from manual metal arc stainless steel (MMA-SS) at concentrations of $63.6{\pm}4.1$ $mg/m^3$ (low dose, containing 1.6 $mg/m^3$ Mn) and $107.1{\pm}6.3$ $mg/m^3$ (high dose, containing 3.5 $mg/m^3$ Mn) total suspended particulates for 2 hrs per day, in an inhalation chamber over a 60-day period. Blood, brain, lungs and liver samples were collected after 2 hr, 15, 30, and 60 days of exposure and the tissues analyzed for their manganese concentrations using an atomic absorption spectrophotometer. Although dose- and time-dependent increases in the manganese concentrations were found in the lungs and livers of the rats exposed for 60 days, only slight manganese increases were observed in the blood during this period. Major statistically significant increases in the brain manganese concentrations were detected in the cerebellum after 15 days of exposure and up until 60 days. Slight increases in the manganese concentrations were also found in the substantia nigra, basal ganglia (caudate nucleus, putamen, and globus pallidus), temporal cortex, and frontal cortex, thereby indicating that the pharmacokinetics and distribution of manganese inhaled from welding fumes would appear to be different from those resulting from manganese-only exposure.

  • PDF