• Title/Summary/Keyword: Low Dose Exposure

Search Result 473, Processing Time 0.026 seconds

Technical Evaluation of Engineering Model of Ultra-Small Transmitter Mounted on Sweetpotato Hornworm

  • Nakajima, Isao;Muraki, Yoshiya;Mitsuhashi, Kokuryo;Juzoji, Hiroshi;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.9 no.2
    • /
    • pp.145-154
    • /
    • 2022
  • The authors are making a prototype flexible board of a radio-frequency transmitter for measuring an electromyogram (EMG) of a flying moth and plan to apply for an experimental station license from the Ministry of Internal Affairs and Communications of Japan in the summer of 2022. The goal is to create a continuous low-dose exposure standard that incorporates scientific and physiological functional assessments to replace the current standard based on lethal dose 50. This paper describes the technical evaluation of the hardware. The signal of a bipolar EMG electrode is amplified by an operational amplifier. This potential is added to a voltage-controlled crystal oscillator (27 MHz, bandwidth: 4 kHz), frequency-converted, and transmitted from an antenna about 10 cm long (diameter: 0.03 mm). The power source is a 1.55-V wristwatch battery that has a total weight of about 0.3 g (one dry battery and analog circuit) and an expected operating time of 20 minutes. The output power is -7 dBm and the effective isotropic radiated power is -40 dBm. The signal is received by a dual-whip antenna (2.15 dBi) at a distance of about 100 m from the moth. The link margin of the communication circuit is above 30 dB within 100 m. The concepts of this hardware and the measurement data are presented in this paper. This will be the first biological data transmission from a moth with an official license. In future, this telemetry system will improve the detection of physiological abnormalities of moths.

Measuring Absorbed Dose from Medical X-ray Equipment Using Optically Stimulated Luminescence Dots (광자극선량계의 저에너지 엑스선 특성비교)

  • Jung, Sook Jin;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.79-83
    • /
    • 2018
  • In this paper, we measured and analyzed the dose correction factor, absorbed dose linearity, peak voltage X-ray response, angular dependence. Exposure dose correction factor, absorbed dose linearity, and peak voltage linearity using the medical X-ray generator were all in accordance with IEC-62387-1 (2007). The reference to the dosimetry direction at 0, 30, and 60 degrees relative to baseline radiation exposure was -29% (${\pm}30^{\circ}$) and + 67% (${\pm}60^{\circ}$). The values measured at $30^{\circ}$ were -8% lower than the standard and -18% lower than the standard at $60^{\circ}$. Therefore, the effect of direction should be corrected when using OSL dot dosimeter.

Pesticide Exposure and Health (농약 노출과 건강)

  • Lee, Won-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.81-93
    • /
    • 2011
  • Although pesticides have increased crop production and controlled disease, they have produced a number of adverse health effects. Pesticides have potential human toxicity and a variety of groups, such as farmers or industrial workers, as well as the general population, are exposed to pesticides. The purpose of this article, therefore, is to provide an overview of pesticide exposure and health through a literature review, focusing on exposure assessment, acute poisoning, chronic health effects, and future research needs. The exposure types and levels of pesticides vary by study subjects and need to be assessed by integrating several methods focused on the epidemiological purpose. Acute pesticide poisoning is a major public health problem in the world. Paraquat is the main causative pesticide for acute poisoning in Korea and should be banned in order to save several thousands of lives every year. Occupational pesticide exposure also causes numerous chronic diseases among farmers and industrial workers, including cancers, respiratory diseases, depression, retinal degeneration, diabetes, and abnormal menstrual cycle. However, controversy exists regarding the long-term effects of low-dose environmental pesticide exposure. The area of pesticide study is relatively new with broad study populations and it has received little academic and policy attention, particularly in Korea. More detailed studies investigating the risk of pesticide-related health effects and intervention efforts to reduce the problems are needed in Korea.

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF

Effect of Red Ginseng on Radiation-induced Learning and Memory Impairment in Mouse (방사선 조사 마우스에서 학습기억 장애에 대한 홍삼의 효과)

  • Lee, Hae-June;Kim, Joong-Sun;Moon, Chang-Jong;Kim, Jong-Choon;Jo, Sung-Kee;Jang, Jong-Sik;Kim, Sung-Ho
    • Journal of Ginseng Research
    • /
    • v.33 no.2
    • /
    • pp.132-138
    • /
    • 2009
  • Previous studies suggest that even low-dose irradiation can lead to progressive cognitive decline and memory deficits, which implicates, in part, hippocampal dysfunction in both humans and experimental animals. In this study, whether red ginseng (RG) could attenuate memory impairment was investigated through a passive-avoidance and object recognition memory test, as well as the suppression of hippocampal neurogenesis, using the TUNEL assay and immunohistochemical detection with markers of neurogenesis (Ki-67 and doublecortin (DCX)) in adult mice treated with a relatively low-dose exposure to gamma radiation (0.5 or 2.0 Gy). RG was administered intraperitonially at a dosage of 50 mg/kg of body weight, at 36 and 12 h pre-irradiation and at 30 minutes post-irradiation, or orally at a dosage of 250 mg! kg of body weight/day for seven days before autopsy. In the passive-avoidance and object recognition memory test, the mice that were trained for one day after acute irradiation (2 Gy) showed significant memory deficits compared with the sham controls. The number of TUNEL-positive apoptotic nuclei in the dentate gyrus (DG) was increased 12 h after irradiation. In addition, the number of Ki-67- and DCX-positive cells was significantly decreased. RG treatment prior to irradiation attenuated the memory defect and blocked apoptotic death as well as a decrease in the Ki-67- and DCX-positive cells. RG may attenuate memory defect in a relatively low-dose exposure to radiation in adult mice, possibly by inhibiting the detrimental effect of irradiation on hippocampal neurogenesis.

IDENTIFICATION OF GENES EXPRESSED IN LOW-DOSE-RATE γ-IRRADIATED MOUSE WHOLE BRAIN

  • Bong, Jin Jong;Kang, Yu Mi;Choi, Seung Jin;Kim, Dong-Kwon;Lee, Kyung Mi;Kim, Hee Sun
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.166-171
    • /
    • 2013
  • While high-dose ionizing radiation results in long term cellular cytotoxicity, chronic low-dose (<0.2 Gy) of X- or ${\gamma}$-ray irradiation can be beneficial to living organisms by inducing radiation hormesis, stimulating immune function, and adaptive responses. During chronic low-dose-rate radiation (LDR) exposure, whole body of mice is exposed to radiation, however, it remains unclear if LDR causes changes in gene expression of the whole brain. Therefore, we aim to investigate expressed genes (EGs) and signaling pathways specifically regulated by LDR-irradiation ($^{137}Cs$, a cumulative dose of 1.7 Gy for total 100 days) in the whole brain. Using microarray analysis of whole brain RNA extracts harvested from ICR and AKR/J mice after LDR-irradiation, we discovered that two mice strains displayed distinct gene regulation patterns upon LDR-irradiation. In ICR mice, genes involved in ion transport, transition metal ion transport, and developmental cell growth were turned on while, in AKR/J mice, genes involved in sensory perception, cognition, olfactory transduction, G-protein coupled receptor pathways, inflammatory response, proteolysis, and base excision repair were found to be affected by LDR. We validated LDR-sensitive EGs by qPCR and confirmed specific upregulation of S100a7a, Olfr624, and Gm4868 genes in AKR/J mice whole brain. Therefore, our data provide the first report of genetic changes regulated by LDR in the mouse whole brain, which may affect several aspects of brain function.

Estimated Additional Number of Workers and Additional Collective Dose by Reducing Dose Limits (선량한도 하향이 방사선작업인력 및 집단선량에 미치는 영향예측)

  • Ha, Chung-Woo;Na, Seong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.149-157
    • /
    • 1998
  • An analysis has been performed to estimate the additional number of workers and the additional collective dose in man-cSv which would be required, nuclear industry-wide as a result of reducing individual dose limit. This analysis can be extended to the reduction in the dose limits recommended by ICRP Publ.60 and BEIR V report as well as the proposed dose limits by regulatory authorities. An industry-wide database was employed in the analysis based on a summary of industry-wide occupational radiation exposure compiled by the Korea Radioisotope Association. Correlation model was employed to compute the affects of setting specific annual individual dose limits. In this study, we have addressed worker non-productivity while in the radiation environment on a parametric or 'sensitivity analysis' basis. This alleviates the need for developing such data underlying a summation of many individual tasks at many nuclear facilities. It has the advantage that very low non-productivity assumptions can readily be defended as conservative, in that it is difficult to approach such low worker non-productivity factors even in the best of environments in any industry. On a per facility basis, for calendar year 1997, the number of workers required would be increased from 231 workers to 269 workers and collective man-cSv dose would be also increased by approximately fourteen percent if the individual dose limit was reduced to 2 cSv/y and an individual worker non-productivity fraction of 0.1 is assumed.

  • PDF

Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose (자외선 조사량에 따른 태양전지 모듈 봉지재의 특성 분석)

  • Lee, Song-Eun;Bae, Joon-Hak;Shin, Jae-Won;Jeon, Chan-Wook
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.81-85
    • /
    • 2018
  • The photovoltaic modules installed in the actual field are affected by various external environments and the electrical performance output value is generally lowered compared to initial output value. The most of photovoltaic modules consists of low iron glass, encapsulant (EVA), back sheet, frame and junction box assembly based on the solar cells. In this paper, the characteristics of encapsulant which is an important constituent material of photovoltaic module were verified by maximum power determination, electro luminescence images, yellowness index measurement, and gel content measurement after ultraviolet (UV) irradiation exposure. The most commonly installed 72 cells crystalline photovoltaic modules were tested after various UV exposure of 0, 15, 30, and $60kWh/m^2$ and compared with the reference module. After UV exposure of $15kWh/m^2$, which is the current international test condition, a small amount of change was observed in yellowness index and electroluminescence, while a gell content rapidly increased. At a cumulative dose of $60kWh/m^2$, which will be a new international test condition in the near future, however, the yellowness index increased sharply and showed the greatest output power drop.

Study of Factors Controlling Exposure Dose and Image Quality of C-arm in Operation Room according to Detector Size of It (Mainly L-Spine AP Study) (수술 중 C-Arm Neutral AP 검사 시 조절인자에 따른 피폭선량 및 화질비교(L-Spine AP검사를 기준으로))

  • CHOI, Sung-Hyun;JO, Hwang-Woo;Dong, Kyung-Rae;Chung, Woon-Kwan;Choi, Eun-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: Time of operation has been reduced and accuracy of operation has been improved since C-arm, which offer real-time image of patient, was introduced in operation room. However, because of the contamination of patient, C-arm could not be used more appropriately. Therefore, this study is to know factors of controlling exposure dose, image quality and the exposed dose of health professional in operation room. Materials and methods: Height of Wilson frame (bed for operation) was fixed at 130 cm. Then, Model 76-2 Phantom, which was set by assembling manual of Fluke Company, was set on the bed. Head/Spine Fluoroscopy AEC mode was set for exposure condition. According to detector size of C-arm, the absorbed dose per min was measured in the 7 steps OFD (cm) from 10 cm to 40 cm (10, 15, 20, 25, 30, 35, 40 cm). In each step of OFD, the absorbed dose per min of same diameter of collimation was measured. Moreover, using Nero MAX Model 8000, exposure dose per min was measured according to 3 step of distance from detector (20 cm, 60 cm, 100 cm). Finally, resolution was measured by CDRH Disc Phantom and magnification of each OFD was measured by aluminum stick bar. Result: According to detector size of C-arm, difference of absorbed dose shows that the dose of 20 cm OFD is 1.750 times higher than the dose of 40 cm OFD. It means that the C-arm, which has smaller size of detector, shows the bigger difference of absorbed dose per min (p<0.05). In the difference of absorbed dose in the same step of OFD (from 20 cm to 40 cm), the absorbed dose of 9 inch detect or C-arm was 1.370 times higher than 12 inch' s (p<0.05). When OFD was set to 20 cm OFD, the absorbed dose of non-collimation case was approximately 0.816 times lower than the absorbed dose of collimation cases (p<0.05). When the distance was 20 cm from detector, exposed does includes first-ray and scatter-ray. When the distance was 60 cm and 100 cm from detector, exposed does includes just scatter-ray. So, there was the 2.200 times difference of absorbed does. Finally, when OFD was increased, spatial resolution was 4 to 5 step was increased. However, low contrast resolution was not relative. Moreover, there was 1.363 times difference of magnification (p<0.05). Conclusion: When C-Arm is used, avoiding contamination of patient is more important factor than reducing exposed dose of health professional in operation room. Just controlling exposure time is just way to reduce the exposed does of workers. However, in the case, non-probability influence could be occurred. Therefore, this study proved that the exposed dose will be reduced if the factors such as using small detector size of C-arm, setting OFD from 20 cm to 25 cm and non-collimating. Moreover, dose management of C-arm in the non-interesting area will be considered additionally.

A Calculation of the Cosmic Radiation Dose of a Semiconductor in a Geostationary Orbit Satellite Depending on the Shield Thickness (차폐체 두께에 따른 정지궤도위성용 반도체의 우주방사선 피폭 계산)

  • Heo, Jeong-Hwan;Ko, Bong-Jin;Chung, Bum-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.476-483
    • /
    • 2009
  • Cosmic ray is composed of nuclear particles moving at a light speed. The cosmic ray affects the performance and the reliability of semiconductor devices by ionizing the semiconductor material. In this study, the radiation effects of protons, electrons, and photons, which compose the cosmic ray, on the GOS(Geostationary Orbit Satellite) were evaluated using the Monte-Carlo N-Particle code. The GOS was chosen due to the comparatively long exposure to the cosmic ray as it stays in the geostationary orbit more than 10 years. As the absorbed dose of semiconductor from electrons is much larger than those of protons, photons, and the secondary radiation, most of the radiation exposure of the semiconductors in the GOS results from that of electrons. When we compare the calculated absorbed dose with the radio-resistance of semiconductor, the Intel 486 of the Intel company is not suitable for the GOS applications due to its low radio-resistance. However RH3000-20 of MIPS and Motorola 602/603e can be applied to the Satellite when the aluminium shield is thicker than 3 mm.