• Title/Summary/Keyword: Low Dose

Search Result 2,861, Processing Time 0.031 seconds

Usability Evaluation of Applied Low-dose CT When Examining Urinary Calculus Using Computed Tomography (컴퓨터 단층촬영을 이용한 요로결석 검사에서 저선량 CT의 적용에 대한 유용성 평가)

  • Kim, Hyeon-Jin;Ji, Tae-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.6
    • /
    • pp.81-85
    • /
    • 2017
  • The aim of this study was to evaluate the usability of applied Low dose Computed Tomography(LDCT) protocol in examining urinary calculus using computed tomography. The subjects of this study were urological patients who visited a medical institution located in Busan from June to December 2016 and the protocol used in this study was Adaptive Statistical Iterative Reconstruction: low-dose CT with 50% Adaptive Statistical Iterative Reconstruction (ASIR). As results of quantitative analysis, the mean pixel value and standard deviation within kidney region of image(ROI)of the axial image were $26.21{\pm}7.08$ in abdomen CT pre scan and $20.03{\pm}8.16$ in low-dose CT. Also the mean pixel value and standard deviation within kidney ROI of the coronal image were $22.07{\pm}7.35$ in abdomen CT pre scan and $21.67{\pm}6.11$ in low dose CT. The results of qualitative analysis showed that four raters' mean values of observed kidney artifacts were $19.14{\pm}0.36$ when using abdomen CT protocol and $19.17{\pm}0.43$ in low-dose CT, and the mean value of resolution and contrast was $19.35{\pm}0.70$ when using abdomen CT protocol and $19.29{\pm}0.58$ in low-dose CT. Also the results of a exposure dose analysis showed that the mean values of CTDIvol and DLP in abdomen CT pre scan were 18.02 mGy and $887.51mGy{\cdot}cm$ respectively and the mean values of CTDIvol and DLP when using low-dose CT protocol were 7.412 mGy and $361.22mGy{\cdot}cm$ respectively. The resulting dose reduction rate was 58.82% and 59.29%, respectively.

A Comparison of Dose in Changed Technique Factor Using X-ray Imaging System (X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가)

  • Han, Dong-Kyoon;Ko, Shin-Gwan;Seon, Jong-Ryul;Yoon, Seok-Hwan;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer's exposure dose, studying methods which can predict patient's radiation exposure dose more exactly.

  • PDF

Proliferation of Dopamine $D_2$-Like Receptors after Treatment with Low Dose Haloperidol in Rat Brain (저용량의 Haloperidol투여에 의해 유발된 백서 뇌내 Dopamine $D_2$양 수용체증식)

  • Kim, Hwang-Jin;Hahn, Kyu-Hee
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.240-244
    • /
    • 1996
  • The effects of chronic treatment with haloperidol on the binding capacities of dopamine(DA) $D_2$-like receptor were investigated in rat striatum and olfactory tubercle. The authors tried to confirm the dose-response effects with usual dose and low dose haloperidol. Rats were treated with haloperidol(0.05, 0.15, 0.5, 1.5mg/kg/day in drinking water) for four weeks. Saturation analysis of the binding of [$^3H$]spiperone to striatal membranes showed that the haloperidol treatment(0.05, 0.5, 1.5mg/kg) induced significant proliferation. The changes of dissociation constant(Kd) were not significant in striatum. The maximal binding density(Bmax) and Kd increased remarkably following the treatment with usual dose haloperidol (1.5mg/kg) in olfactory tubercle. Although there was increasing trend other the treatment with low dose haloperidol, the change of Bmax was not significant statistically. The present findings indicate that low dose haloperidol induces the proliferation of DA $D_2$-like receptor in striatum and interact with the dopaminergic transmission which might underlie the antipsychotic effect. This finding may support the recent clinical suggestion on the low dose strategy in the treatment of schizophrenia.

  • PDF

Bioassay in BALB/c mice exposed to low dose rate radiation (저선량율 방사선 조사한 BALB/c 마우스에서의 영향평가)

  • Kim, Sung-Dae;Gong, Eun-Ji;Bae, Min-Ji;Yang, Kwang-Mo;Kim, Joong-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.159-166
    • /
    • 2012
  • The present study was performed to investigate the toxicity of low-dose-rate irradiation in BALB/c mice. Twenty mice of each sex were randomly assigned to four groups of five mice each and were exposed to 0 (sham), 0.02, 0.2, or 2 Gy, equivalents to low-dose-rate irradiation to 3.49 $mGy{\cdot}h^{-1}$. Urine, blood, and blood biochemistry were analyzed, and organ weight was measured. The low-dose-rate irradiation did not induce any toxicologically significant changes in mortality, clinical signs, body weight, food and water consumption, urinalysis, and serum biochemistry. However, the weights of reproductive organs including the testis, ovary, and uterus decreased in a dose-dependent manner. Irradiation at 2 Gy significantly decreased the testis, ovary, and uterus weights, but did not change the weights of other organs. There were no adverse effects on hematology in any irradiated group and only the number of neutrophils increased dose dependently. The low-dose-rate irradiation exposure did not cause adverse effects in mice at dose levels of 2 Gy or less, but the reproductive systems of male and female mice showed toxic effects.

Experimental study on build up characteristic of glass dosimeter of preheat and Non-preheat in low energy according to delay time (저에너지X선 영역에서 유리선량계의 preheat과 Non-preheat과의 시간에 따른 build up 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Ki-Won;Son, Soon-Yong;Lim, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3412-3418
    • /
    • 2013
  • The Purpose of this study was to evaluate by comparing the dose change and build up characteristic according to delay time in 30 days of glass dosimeter processed preheat and non preheat when measuring accumulation dose of radiation by using glass dosimeter over the long haul. For obtaining low dose with 0.1 mGy, 1 mGy and 5 mGy, we employed diagnostic generator AccuRay-650R. We compared the build up characteristic over the long haul by exposuring radiation to 30 glass dosimeters sorted into 10 glass dosimeters per tube voltage and current. In Non preheat glass dosimeter, initial measured dose was inferior to exposed dose but as time goes on, was close to exposed dose steadily. In 72 hour after experiment end, non preheat glass dosimeters were not indicated the difference from preheat glass dosimeters and statistical analysis were meaningful (p>0.05). Initial measured dose for low glass dosimeter processed preheat was close to exposed dose and stable. After 15 days dose was gradually increased. Previous study characteristics of glass dosimeter were with respect to characteristic of glass dosimeter in high dose of high energy area. However, in this study, we make a judgment to measure the dose of glass dosimeter without preheat processing when measuring the accumulation dose of low dose in conclusion.

A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter (유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구)

  • Noh, Sung Jin;Kim, Hyo Jin;Kim, Hyun;Jeong, Dong Hyeok;Son, Tae Gen;Kim, Jung Ki;Yang, Kwangmo;Nam, Sang-Hee;Kang, Yeong-Rok
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.202-210
    • /
    • 2015
  • The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using $^{137}Cs$ irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological & Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

Effect of Low Dose ${\gamma}$ Radiation on the Dormancy and Growth of in vitro Microtuvers of Potato(Solanum Tuberosum L.) (저선량 ${\gamma}$선이 기냐 생산된 감자 소괴경의 휴면과 생에 미치는 효과)

  • Kim, Dong-Hee;Back, Myung-Hwa;Jeon, Jae-Heung;Kim, Jae-Sung
    • Korean Journal of Environmental Biology
    • /
    • v.19 no.4
    • /
    • pp.270-277
    • /
    • 2001
  • To observe the stimulating effect of low dose ${\gamma}$ radiation on the dormancy breaking and growth, microtubers induced in vitro of two potato (Solanum tuberosum L. cv. Dejima and cv. Superior) cultivars with different storage duration were irradiated with ${\gamma}$ radiation at the dose of $0.5{\sim}30$ Gy. Sprouting rate, growth and tuber yield of ‘Dejima’ microtuber were increased by ${\gamma}$ radiation in the range of $2{\sim}16$ Gy. In the microtuber of ‘Superior’, the sprouting rate was promoted by 2 Gy and 4 Gy irradiation, and the growth and tuber yield by 0.5 Gy and 4 Gy irradiation. There were not that much difference in chlorophyll content of potato plantlet by the low dose ${\gamma}$ irradiation. These results suggested that low dose ${\gamma}$ radiation stimulated the dormancy breaking and potato growth.

  • PDF

Low-dose Radioactive I-131 Therapy after Total Thyroidectomy for Differentiated Thyroid Cancer (갑상선 분화암 수술 후 저용량 방사성 옥소(I-131)요법)

  • Choi Chung-Jin;Jung Sung-Hoo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.214-219
    • /
    • 1998
  • Objectives: To assess the effectiveness of the low-dose(30mCi) I-131 ablation therapy for remnant thyroid tissue following total thyroidectomy for differentiated thyroid cancer. Methods: Between March 1995 and December 1997, forty-eight patients were given ablative doses(30mCi) of I-131 after total thyroidectomy for differentiated thyroid cancer in the presence of I-131 uptake in remnant thyroid tissue. Effective ablation of remnant thyroid tissue was determined by following I-131 whole body scan. if remnant thyroid tissue remained, we repeated the same management at 6 months interval. Results: Thirty-eight(79.1%) patients had papillary, 8(16.7%) follicular, 1(2.1%) medullary and 1(2.1%) Hurthle cell type cancer. Forty-eight patients underwent total thyroidectomy, among those central neck dissection was performed in 35 cases, and modified radical neck dissection in 14 cases. Postoperative complication developed in 8 cases, which included 4 cases of transient hypoparathyroidism, 1 case of permanent hypoparathyroidism, 2 cases of transient recurrent laryngeal nerve palsy, and 1 case of wound hematoma. There were significant remnant thyroid tissue in 46 cases(95.8%) of patients after total thyroidectomy, which could be ablated by low dose(30mCi) I-131. There were no statistical difference between operative procedures and number of treatment of I-131. Conclusions: These results suggested that repeated low-dose(30mCi) I-131 therapy would be needed, therefore, high -dose I-131 therapy could be considered as ablation therapy for the remnant thyroid tissue after total thyroidectomy for differentiated thyroid cancer.

  • PDF

Protective Effect of Astragalus polysaccharides on Liver Injury Induced by Several Different Chemotherapeutics in Mice

  • Liu, Wen;Gao, Fang-Fang;Li, Qun;Lv, Jia-Wei;Wang, Ying;Hu, Peng-Chao;Xiang, Qing-Ming;Wei, Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10413-10420
    • /
    • 2015
  • Side effects are an unavoidable consequence of chemotherapy drugs, during which liver injury often takes place. The current study was designed to investigate the protective effect of Astragalus polysaccharides (APS) against the hepatotoxicity induced by frequently-used chemical therapy agents, cyclophosphamide (CTX), docetaxel (DTX) and epirubicin (EPI)) in mice. Mice were divided into five groups, controls, low or high dose groups ($DTX_L$, $CTX_L$, $EPI_L$ or $DTX_H$, $CTX_H$, $EPI_H$), and low or high dose chemotherapeutics+APS groups ($DTX_L$+APS, $CTX_L$+APS, $EPI_L$+APS or $DTX_H$+APS, $CTX_H$+APS, $EPI_H$+APS). Controls were treated with equivalent normal saline for 28 days every other day; low or high dose group were intraperitoneal (i.p) injected with low or high doses of CTX, DTX and EPI for 28 days every other day; low or high dose chemotherapeutics+APS group were separately intraperitoneal (i.p) injected with chemotherapeutics for 28 days every other day and i.p with APS (100 mg/kg) for 7 days continually from the 22th to the 28th days. The body weight, serum levels of alanine aminotransferase (ALT) and aspartate aminotransferase (AST), histopathological features, and ultrastructure morphological change of liver tissues, protein expression level of caspase-3 were estimated at different time points. With high dose treatment of DTX, CTX and EPI, weight gain was inhibited and serum levels of ALT and AST were significantly increased. Sections of liver tissue showed massive hepatotoxicity in $CTX_H$ group compared to the control group, including hepatic lobule disorder, granular and vacuolar degeneration and necrosis in hepatic cells. These changes were confirmed at ultrastructural level, including obvious pyknosis, heterochromatin aggregation, nuclear membrane resolution, and chondrosome crystal decrease. Western blotting revealed that the protein levels of caspase-3 increased in $CTX_H$ group. The low dose groups exhibited trivial hepatotoxicity. More interestingly, after 100 mg/kg APS, liver injury was redecued not only regarding serum transaminase activities (low or high dose chemotherapeutics+APS group), but also from pathological and ultrastructural changes and the protein levels of caspase-3 ($CTX_H$+APS group). In conclusion, DTX, CTX and EPI induce liver damage in a dose dependent manner, whereas APS exerted protective effects.

A Study on Radition-Induced Current in Insulating Oil during X-ray Irradiation (방사선(放射線) 조사(照射) 중(中) 절연유(絶緣油)의 유기전류(誘起電流)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Duck-Chool;Chung, Yon-Tack
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 1988
  • This study was measured the radiation-induced current - X-ray dose, dose rate, X-ray quality, time, temperature, electric field characteristics and the dependence of gap length in insulating oil under of D.C. Voltage before, during and after X-ray irradiation. The obtained results can be summarized as following. 1. The radiation - induced current is more the dependence of X-ray quality (tube voltage) than quantity (tube current), the dependence of quantity is appeared at the high than low X-.ay tube voltage. 2. The dependence of dose rate is appeared at the more dose rate, and ${\triangle}\;=\;0.64{\sim}0.74$. 3. The higher temperature of insulating oil and X-ray tube voltage (X-ray quality) is increased, at the low electric field, the more radiation-induced current. 4. $G_{eq}-G_{o}(={\triangle}G)$ is increased at the low than high temperature, high than low X-ray quality. 5. The dependence of temperature is appeared before than during X-ray irradiation. 6. The RIC saturation region is appeared at the high than low insulating oil temperature during (1000 V/cm above) than before (4000 V/cm above) X-ray irradiation.

  • PDF