• 제목/요약/키워드: Low Contrast Image

Search Result 454, Processing Time 0.027 seconds

Halftoning Method Using the Dispersed CMY Dithering and Blue Noise Mask (블루 노이즈 마스크와 분산 CMY 디더링을 이용한 하프토닝)

  • 김윤태;조양호;이철희;하영호
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • In this paper, we propose a new method dispersing spatially C(Cyan), M(Magenta), Y(Yellow) instead of K(black) in the bright region. The overlapping of black dots decreases brightness in the dark region, and black dots are very sensitive to human visual system in the bright region. Therefore, to avoid this problem, bright and dark gray region in the color image is considered in the proposed approach. A new method which uses CMY simultaneously in single mask is proposed, and CMY dots are used dispersing spatially for the bright region instead of black dot by this method. And tone curve connection is used to consider the gray level of dark region. In previous method, BNM (Blue Noise Mask) has high granularity and a narrow dynamic range. But the proposed method has the low granularity, wide dynamic range, and high contrast properties. Because the proposed method uses three times dots spatially in the different position than a conventional BNM, it can express more spatial information and a similar gray level compared with BNM.

Studies on the Application of Starch for paper surface sizing(III) - The influence of surface sizing treatment with starch on the quality of uncoated printing paper - (종이 표면 사이즈 프레스용 전분의 적용에 관한 연구 -표면 사이즈용 전분이 백상지 품질에 미치는 영향 -)

  • 윤지영;이용규
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.2
    • /
    • pp.1-12
    • /
    • 2002
  • Starch dissolved in paper-mill wastes, either as a result of poor retention on the paper web or recycling of surface-treated broke, was a major pollutant Laboratory tests were performed by using different kinds of starch as a surface treatment. It was concluded that the use of cationic starch can positively affect the level of starch dissolved in liquid effluents. When cationically modified starches were used for surface sizing, the starch was tightly bound to the paper fibers, it was not removed during the repulping of broke. The result of mill trial in fine paper manufacture for the application of low-viscosity cationic starches used in size press reduced COD load in the effluents and increased One Pass Retention. It had been found that when cationic starch used as a surface sizing agent, more starch was retained on or near the surface of the sheet than with conventional oxidized starches. Thus surface strengths and quality were improved. In addition it is possible to maintain the desired level of starch penetration into the fiber net and improve porosity, opacity and brightness. In contrast, in most cases, dusting problems are notably eliminated. Cationic surface sized starch improved black and color ink-jet print quality in terms of feathering and optical density of the print image. These improved properties were believed to be due to a combination of fiber bonding and surface orientation more uniform starch concentration on the paper surface was resulted. Moreover cationic charges in the paper surface lend themselves excellently to fix ink jet ink anionic in nature.

Improved Object Recognition using Wavelet Transform & Histogram Equalization in the variable illumination (다양한 조명하에서 웨이블렛 변환과 히스토그램 평활화를 이용한 개선된 물체인식)

  • Kim Jae-Nam;Jung Byeong-Soo;Kim Byung-Ki
    • The KIPS Transactions:PartD
    • /
    • v.13D no.2 s.105
    • /
    • pp.287-292
    • /
    • 2006
  • There are two problems associated with the existing principal component analysis, which is regarded as the most effective in object recognition technology. First, it brings about an increase in the volume of calculations in proportion to the square of image size. Second, it gives rise to a decrease in accuracy according to illumination changes. In order to solve these problems, this paper proposes wavelet transformation and histogram equalization. Wavelet transformation solves the first problem by using the images of low resolution. To solve the second problem the histogram equalization enlarges the contrast of images and widens the distribution of brightness values. The proposed technology improves recognition rate by minimizing the effect of illumination change. It also speeds up the processing and reduces its area by wavelet transformation.

Tensile Tests for Copper Thin Foils by Using DIC Method (DIC 법을 이용한 구리박막의 인장시험)

  • Kim, Chung Youb;Song, Ji Ho;Park, Kyung Jo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1529-1534
    • /
    • 2012
  • In this study, tensile tests for 12-${\mu}m$-thick copper thin foils were performed by using the DIC method. The DIC method provided precise stress-strain curves for thin film materials, and a commercial inkjet printer can be simply and effectively used for printing speckle patterns on the specimen of Cu thin films whose surface contrast is too low to apply the DIC method. The mechanical properties of Cu thin foils obtained in this study are as follows: elastic modulus E = 89.2 GPa, 0.2% offset yield stress $S_{0.2%}$= 232.8 MPa, tensile strength $S_u$= 319.2 MPa, elongation at fracture ${\varepsilon}_f$=16.8 %, and Poisson's ratio ${\nu}$= 0.34.

Optical and microstructural behaviors in the GaN-based LEDs structures with the p-GaN layers grown at different growth temperatures (GaN 기반 LED구조의 p-GaN층 성장온도에 따른 광학적, 결정학적 특성 평가)

  • Kong, Bo-Hyun;Kim, Dong-Chan;Kim, Young-Yi;Han, Won-Suk;Ahn, Cheol-Hyoun;Choi, Mi-Kyung;Cho, Hyung-Koun;Lee, Ju-Young;Kim, Hong-Seung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.144-144
    • /
    • 2008
  • Blue light emitting diode structures consisting of the InGaN/GaN multiple quantum wells were grown by metalorganic chemical vapor deposition at different growth temperatures for the p-GaN contact layers and the influence of growth temperature on the emission and microstructural properties was investigated. The I-V and electroluminescence measurements showed that the sample with a p-GaN layer grown at $1084^{\circ}C$ had a lower electrical turn-on voltage and series resistance, andenhanced output power despite the low photoluminescence intensity. Transmission electron microscopy (TEM) revealed that the intense electro luminescence was due to the formation of a p-GaN layer with an even distribution of Mg dopants, which was confirmed by TEM image contrast and strain evaluations. These results suggest that the growth temperature should be optimized carefully to ensurethe homogeneous distribution of Mg as well as the total Mg contents in the growth of the p-type layer.

  • PDF

Model-based Dithering Using Dot Pattern Selection (도트 패턴 선택을 이용한 모델 기반 디더링)

  • Lee, Chae-Soo;Park, Yang-Woo;Uam, Tae-Uk;Jang, Joo-Seok;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.3
    • /
    • pp.247-257
    • /
    • 2001
  • New methods are proposed for printing a full resolution image on a limited output device. The proposed algorithm uses a dot-pattern database that models overlapping phenomena among neighbor printing dots. To solve the problem of dot-overlap, the gray levels of dot-pattern sets were calculated using a circular dot-overlap model and then measured by a spectrometer. Thereafter, in order to improve the visual quality of the color dithering, the contrast sensitivity function of the human visual system was used. As a result, the optimal dot-pattern can be selected from the database. Consequently, the proposed algorithm can produce high quality images while using low-cost color devices.

  • PDF

Cervical Ganglioneuroma Associated with Neurofibromatosis Type 1 (제 1형 신경섬유종증에 동반된 경부 신경절신경종)

  • Choi, Eui-Chul;Kim, Jun-Hyuk;Shin, Ho-Seong;Lee, Ji-Hye;Lee, Young-Man
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.477-480
    • /
    • 2010
  • Purpose: Ganglioneuromas are well-differentiated tumors derived from neuroectodermal neural crest cells. Although these tumors can occur anywhere along the sympathetic chain from the base of the skull to the pelvic cavity, they usually develop in the posterior mediastinum and retroperitoneum these tumors are rarely found in the cervical region. Method: We report the case of a 16-year-old male patient with neurofibromatosis type 1 who was admitted because of a palpable mass centrally located on the left side of the neck. A preoperative contrast-enhanced neck computed tomography image showed a low-density homogeneous mass on the parapharyngeal space along with marked displacement of the trachea and carotid vessels. Round and soft masses were also detected on both axillae. Results: The patient subsequently underwent complete excision of the neck mass via the transcervical approach. The mass was smooth and well encapsulated between the sternocleidomastoid muscle and the trachea. Further, the mass appeared to arise from the cervical sympathetic chain, which was preserved during surgery. Both the axillary masses were also excised. The histopathological findings were ganglioneuroma for the neck mass and neurofibroma for both the axillary masses. Conclusion: Cervical ganglioneuromas are rare tumors that present as enlarging parapharyngeal cervical masses in the oropharynx or neck. To our knowledge, a case of cervical ganglioneuroma associated with neurofibromatosis type 1 has never been reported. In patients with neurofibromatosis, multiple tumors may develop, and therefore periodic clinical and radiological follow-up is recommended. Further, repeated imaging analysis should be performed if the presence of another tumor is suspected.

Development of Triaxial Cells Operable with In Situ X-ray CT for Hydro-Mechanical Laboratory Testing of Rocks (원위치 X-ray CT 촬영이 가능한 암석의 수리-역학 실험용 삼축셀 개발)

  • Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.9
    • /
    • pp.45-55
    • /
    • 2020
  • X-ray computed tomography (CT) is very useful for the quantitative evaluation of internal structures, particularly defects in rock samples, such as pores and fractures. In situ CT allows 3D imaging of a sample subjected to various external treatments such as loading and therefore enables observation of changes that occur during the loading process. We reviewed state-of-the-art of in situ CT applications for geomaterials. Two triaxial cells made using relatively low density but high strength materials were developed aimed at in situ CT scanning during hydro-mechanical laboratory testing of rocks. Preliminary results for in situ CT imaging of granite and sandstone samples with diameters ranging from 25 mm to 50 mm show a resolution range of 34~105 ㎛ per pixel pitch, indicating the feasibility of in situ CT observations for internal structural changes in rocks at the micrometer scale. Potassium iodide solution was found to improve the image contrast, and can be used as an injection fluid for hydro-mechanical testing combined with in situ CT scanning.

Pavement Crack Detection and Segmentation Based on Deep Neural Network

  • Nguyen, Huy Toan;Yu, Gwang Hyun;Na, Seung You;Kim, Jin Young;Seo, Kyung Sik
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.9
    • /
    • pp.99-112
    • /
    • 2019
  • Cracks on pavement surfaces are critical signs and symptoms of the degradation of pavement structures. Image-based pavement crack detection is a challenging problem due to the intensity inhomogeneity, topology complexity, low contrast, and noisy texture background. In this paper, we address the problem of pavement crack detection and segmentation at pixel-level based on a Deep Neural Network (DNN) using gray-scale images. We propose a novel DNN architecture which contains a modified U-net network and a high-level features network. An important contribution of this work is the combination of these networks afforded through the fusion layer. To the best of our knowledge, this is the first paper introducing this combination for pavement crack segmentation and detection problem. The system performance of crack detection and segmentation is enhanced dramatically by using our novel architecture. We thoroughly implement and evaluate our proposed system on two open data sets: the Crack Forest Dataset (CFD) and the AigleRN dataset. Experimental results demonstrate that our system outperforms eight state-of-the-art methods on the same data sets.

Assessment and Comparison of Three Dimensional Exoscopes for Near-Infrared Fluorescence-Guided Surgery Using Second-Window Indocyanine-Green

  • Cho, Steve S.;Teng, Clare W.;Ravin, Emma De;Singh, Yash B.;Lee, John Y.K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.572-581
    • /
    • 2022
  • Objective : Compared to microscopes, exoscopes have advantages in field-depth, ergonomics, and educational value. Exoscopes are especially well-poised for adaptation into fluorescence-guided surgery (FGS) due to their excitation source, light path, and image processing capabilities. We evaluated the feasibility of near-infrared FGS using a 3-dimensional (3D), 4 K exoscope with near-infrared fluorescence imaging capability. We then compared it to the most sensitive, commercially-available near-infrared exoscope system (3D and 960 p). In-vitro and intraoperative comparisons were performed. Methods : Serial dilutions of indocyanine-green (1-2000 ㎍/mL) were imaged with the 3D, 4 K Olympus Orbeye (system 1) and the 3D, 960 p VisionSense Iridium (system 2). Near-infrared sensitivity was calculated using signal-to-background ratios (SBRs). In addition, three patients with brain tumors were administered indocyanine-green and imaged with system 1, with two also imaged with system 2 for comparison. Results : Systems 1 and 2 detected near-infrared fluorescence from indocyanine green concentrations of >250 ㎍/L and >31.3 ㎍/L, respectively. Intraoperatively, system 1 visualized strong near-infrared fluorescence from two, strongly gadolinium-enhancing meningiomas (SBR=2.4, 1.7). The high-resolution, bright images were sufficient for the surgeon to appreciate the underlying anatomy in the near-infrared mode. However, system 1 was not able to visualize fluorescence from a weakly-enhancing intraparenchymal metastasis. In contrast, system 2 successfully visualized both the meningioma and the metastasis but lacked high resolution stereopsis. Conclusion : Three-dimensional exoscope systems provide an alternative visualization platform for both standard microsurgery and near-infrared fluorescent guided surgery. However, when tumor fluorescence is weak (i.e., low fluorophore uptake, deep tumors), highly sensitive near-infrared visualization systems may be required.