• Title/Summary/Keyword: Loss formula

Search Result 294, Processing Time 0.029 seconds

Estimation of exponent value for Pythagorean method in Korean pro-baseball (한국프로야구에서 피타고라스 지수의 추정)

  • Lee, Jang Taek
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.3
    • /
    • pp.493-499
    • /
    • 2014
  • The Pythagorean won-loss formula postulated by James (1980) indicates the percentage of games as a function of runs scored and runs allowed. Several hundred articles have explored variations which improve RMSE by original formula and their fit to empirical data. This paper considers a variation on the formula which allows for variation of the Pythagorean exponent. We provide the most suitable optimal exponent in the Pythagorean method. We compare it with other methods, such as the Pythagenport by Davenport and Woolner, and the Pythagenpat by Smyth and Patriot. Finally, our results suggest that proposed method is superior to other tractable alternatives under criterion of RMSE.

Anti-obesity Effect of Vegetable Formula on Obese Mice in High Fat Diet (고지방식이 비만 마우스에 대한 야채 조성물의 항비만 효과)

  • Lee, Jae-Hyeok;Shin, Tae-Yong;Park, Jeong-Sook
    • Korean Journal of Pharmacognosy
    • /
    • v.50 no.1
    • /
    • pp.46-52
    • /
    • 2019
  • This study was conducted to investigate the cholesterol and Triglyceride (TG) lowering and anti-obesity effects of water extract of vegetable formula (onion 25%, carrot 20%, Cabbage 20%, Sweet Pumpkins 20%, Chinese plum 5%, turmeric 5%, morus leaves 5%, SLS) in mice fed high fat-diet. ICR mice were divided into 3 groups; a normal diet group (ND), a high-fat diet group (HFD), a high-fat diet and SLS with 300 mg/kg treated group (HFD+SLS). Body fat gain was increased by high-fat diet and HFD+SLS group showed a definite weight loss. The total cholesterol level in the HFD+SLS group was 328.4 mg/dl which was 27.4% lower than that in the HFD group and the cholesterol-lowering effect of SLS was confirmed. The HFD + SLS group showed 118.1 mg/dl and the triglyceride level in the serum was decreased by 88.7% compared to the HFD group and SLS significantly decreased blood triglyceride levels. RT-PCR showed that the expression of PPAR-${\gamma}$ and the target gene SCD-1 was inhibited in a dose-dependent manner in the SLS-treated group. These results suggest that the SLS water extract may have a cholesterol and triglyceride-lowering effect and inhibit the expression of PPAR-${\gamma}$ and SCD-1 to have an anti-obesity effect.

Estimating Direct Costs of Enterprises by Personal Information Security Breaches (개인정보 유.노출 사고로 인한 기업의 손실비용 추정)

  • Yoo, Jin-Ho;Jie, Sang-Ho;Lim, Jong-In
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.19 no.4
    • /
    • pp.63-75
    • /
    • 2009
  • Recently personal information security breaches by unauthorised access, mistakenly disclosure or stolen become more frequent and the scale of the economic loss of such incidents is growing. Assessing economic loss of personal information security breaches is needed for decision making of information security investment This paper presents a framework to analyze economic impact of personal information security breaches and develops formula for each element to empirically calculate the economic loss. We also compared annual economic loss of Korea with that of Japan to develop some implications.

Velocity and Flow Friction Characteristic of Working Fluid in Stirling Engine Regenerator (II) - Flow Friction Characteristic of Working Fluid in Stirling Engine Regenerator - (스털링기관 재생기내의 작동유체 유속 및 마찰저항 특성(II) - 작동유체 유동마찰저항 특성 -)

  • Kim, T.H.;Choi, C.R.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • The output of the Stirling engine is influenced by the regenerator effectiveness. The regenerator effectiveness is influenced by heat transfer and flow friction loss of the regenerator matrix. In this paper, in order to provide basic data for the design of regenerator matrix, characteristics of flow friction loss were investigated by a packed method of matrix in the oscillating flow as the same condition of operation in a Stirling engine. As matrices, two different wire screens were used. The results are summarized as follows; 1. With the wire screen of No. 50 as regenerator matrices, pressure drop of working fluid of the oscillating flow is shown as 3 times higher than that of one directional flow, not too much influenced by the number of packed meshes. 2. With the wire screen of No. 100 as regenerator matrices, pressure drop of working fluid of the oscillating flow is shown as 2.5 times on the average higher than that of one directional flow, not too much influenced by the number of packed meshes. 3. Under one directional flow which used regenerator matrices with both 200, 240, and 280 wire screens of No. 50 and 320, 370, and 420 wire screens of No. 100, the relationship between the friction factor and Reynold No. is shown as the following formula. $$f=\frac{0.00326639}{Re\iota}-1.29106{\times}10^{-4}$$ 4. Under oscillating flow which used regenerator matrices with both 200, 240, and 280 wire screens of No. 50 and 320, 370, and 420 wire screens of No. 100, the relationship between the friction factor and Reynold No. is shown as the following formula. $$f_r=\frac{0.000918567}{Re\iota}+1.86101{\times}10^{-5}$$ 5. The pressure drop is shown as high in proportion as the number of meshes has been higher, and the number of packed wire screens as matrices increases.

Optimal Treatment of Unconstrained Visco-elastic Damping Layer on Beam to Minimize Vibration Responses (동적응답을 최소화하는 비구속형 제진보의 제진부위 최적설계)

  • Lee, Doo-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.656-661
    • /
    • 2005
  • An optimization formulation of unconstrained damping treatment on beams is proposed to minimize vibration responses using a numerical search method. The fractional derivative model is combined with RUK's equivalent stiffness approach in order to represent nonlinearity of complex modulus of damping materials with frequency and temperature. The loss factors of partially covered unconstrained beam are calculated by the modal strain energy method. Vibration responses are calculated by using the modal superposition method, and of which design sensitivity formula with respect to damping layout is derived analytically. Plugging the sensitivity formula into optimization software, we can determine optimally damping treatment region that gives minimum forced response under a given boundary condition. A numerical example shows that the proposed method is very effective in minimizing vibration responses with unconstrained damping layer treatment.

  • PDF

Coordinate and Length of Straight Transmission Line Minimally connecting X-Y axis via a Specific Point (특정지점을 경유하며 X-Y 축을 최단거리로 연결하는 전선로의 길이 산정)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.65-70
    • /
    • 2015
  • Minimal line length enables low-cost construction of the transmission lines and low-loss transportation of electric power. This paper presents a derivation to determine the coordinate and length of the straight line that minimally connects two perpendicular lines x-axis and y-axis via a specific point, using the optimization technique. The author shows a formula to obtain the minimal length, which is represented by the cube root of the coordinate given by the specific point. Case studies have been also discussed to prove the optimal solutions derived by the proposed formula.

Intersymbol Interferences Due to Mismatched Roll-off Factors and Sampling-Time Jitter in a Gaussian Noise Channel

  • Park, Seung Keun;Mok, Jin Dam;Na, Sang Sin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2E
    • /
    • pp.47-54
    • /
    • 1997
  • This paper presents two results on intersymbol interferences in baseband digital communication over an additive white Gaussian noise channel-the interferences due to mismatched square-root raised-cosine filters, in which the filters have different roll-off factors, and / or due to sampling-time jitter. The result for the mismatched filters is that even the jitter-free sampling causes intersymbol interference and it is negligibly small for a wide range of signal-to-noise ratio up to 10dB, for the roll-off factor ranging from 0.2 to 0.5, the mismatch loss being within 0.1dB from the optimum at around 10-6 .For jitter interference an approximation formula for the bit error probability is derived in case of the matched filters, which shows how the roll-off factors and the amount of jitter affect the system performance. The formula is reasonably accurate.

  • PDF

Clinical Application of Shinkihuan in Hyungsang Medicine (신기환(腎氣丸)에 대(對)한 형상의학적(形象醫學的) 고찰(考察))

  • Kim Pan-Joon
    • Herbal Formula Science
    • /
    • v.10 no.2
    • /
    • pp.251-260
    • /
    • 2002
  • The application of Shinkihuan umder the combination of configuration, color, pulse and symptoms leads to the following conclusions: 1. Shinkihuan is applied to the diseases related with lung, kidney and the spine: difficult urination of old people, shortness of breath, hematuria, loss of voice, distorted vision, deafness of deficiency, hemorrhoids, thirst, carbuncle, suppurative infection, children's retardation of walking and noma, etc... 2. The effect of Shinkihuan is as follows. It nourishes the lung, replenishes the kidney fluid, relieves the phlegm, tranquilizes fever due to deficiency of blood and reinforces the liver. 3. Shinkihuan is appropriate for the persons with the following characteristics in configuration: male, tall, thin, dam-typed, inverted-triangular, prominent nosed and dry.

  • PDF

A New Algorithm for Contingency Analysis (새로운 상정사고 해석 알고리)

  • 박영문;김재철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.6
    • /
    • pp.232-240
    • /
    • 1984
  • This paper presents a new algorithm for power system contingency analysis and sensitivity matrix associated with the contingency measures. The algorithm has several advantages over conventional ones in terms of both accuracy and time of computation by improving base A.C. load flow calculation scheme, contingency evaluaiton formula based on a variable slack generating power concept and transmission loss formula. The algorithm was tested for the 5-bus system and 24-bus IEEE Reliability Test system with satisfactory results.

  • PDF

Core Loss Analysis of Non-oriented Electrical Steel Under Magnetic Induction Including Higher Harmonics

  • Cho, Chuhyun;Son, Derac;Cho, Youk
    • Journal of Magnetics
    • /
    • v.6 no.2
    • /
    • pp.66-69
    • /
    • 2001
  • The actual magnetic induction waveform of cores in electrical machines is not sinusoidal i.e. higher harmonics are always included. Thus the core loss in actual electrical machines is different from the core loss which is measured by the standard method, because the waveform of magnetic induction should be sinusoidal in the standard testing method. Core loss analysis under higher harmonic induction is always important in electric machine design. In this works we measured the core loss when a hysteresis loop has only one period of an ac minor loop of higher harmonic frequency, depending on the position of the ac minor loop of relative to the fundamental harmonic frequency. From this experiment, the core loss P(B/sub 0/f/sub 0/, B/sub h/, nf/sub 0/)) under a higher harmonic magnetic induction B/sub h/ could be expressed by the linear combination the core loss at fundamental harmonic frequency P/sub c/(B/sub 0/, f/sub 0/), the core loss of ac minor loop at zero induction region of the major hysteresis loop P/sub cL/ (B/sub h/, nf/sub 0/), and the core loss of an ac minor loop in the high induction region of the major hysteresis loop P/sub cH/ (B/sub h/, nf/sub 0/) i.e., P/sub c/, (B/sub 0/, f/sub 0/, B/sub h/, nf/sub 0/)=P/sub c/ (B/sub 0/, f/sub 0/,)+(n-1)[k₁(B/sub 0/) P/sub cL/ (B/sub h/, nf/sub 0/)+(1-k₁(B/sub 0/)) P/sub cH/ (B/sub h/, nf/sub 0/)]. This will be useful formula for electrical machine designers and one of effective methods to predict core loss including higher harmonic induction.

  • PDF