• Title/Summary/Keyword: Loss Minimization

Search Result 243, Processing Time 0.022 seconds

A study on analysis of particle swarm optimization algorithm for the optimum design of rectenna for wireless power transmission (무선전력전송용 렉테나 최적 설계를 위한 PSO 알고리즘 분석 연구)

  • Kim, Koon-Tae;Nam, Yeong-Bin;Oh, Seung-Hun;Lee, Jung-Hyeok;Kang, Seong-In;Kim, Hyeong-Seok
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.11 no.2
    • /
    • pp.34-38
    • /
    • 2012
  • In this paper, the particle swarm optimization (PSO) algorithm is adopted to design a modified ring-slot type patch rectenna with a resonance frequency of 2.45GHz. In order to accomplish minimization of dimensions and circular polarization (CP) and harmonic suppression, axial direction slits and side-cuts are added to the patch of the ring. The PSO manipulated this kind of multi-dimensional problem very well, and as a result, the designed rectenna shows a desirable performance of return loss of 21.36dB and axial ratio of 2.92dB at the frequency of 2.45GHz with compact sizing.

  • PDF

Enabling Energy Efficient Image Encryption using Approximate Memoization

  • Hong, Seongmin;Im, Jaehyung;Islam, SM Mazharul;You, Jaehee;Park, Yongjun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.3
    • /
    • pp.465-472
    • /
    • 2017
  • Security has become one of the most important requirements for various devices for multi-sensor based embedded systems. The AES (Advanced Encryption Standard) algorithm is widely used for security, however, it requires high computing power. In order to reduce the CPU power for the data encryption of images, we propose a new image encryption module using hardware memoization, which can reuse previously generated data. However, as image pixel data are slightly different each other, the reuse rate of the simple memoization system is low. Therefore, we further apply an approximate concept to the memoization system to have a higher reuse rate by sacrificing quality. With the novel technique, the throughput can be highly improved by 23.98% with 14.88% energy savings with image quality loss minimization.

Critical Banded Wavelet Packet-Based Spectral Subtractions for Speech Enhancement (음성신호개선을 위한 임계대역 웨이블렛 패킷 기반의 스펙트럼 차감법)

  • Chang, Sung-Wook;Yang, Sung-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4E
    • /
    • pp.125-133
    • /
    • 2004
  • In this paper, we propose a critical banded wavelet packet-based spectral subtraction for speech enhancement. Critical banded wavelet packet, which reflects the human auditory system, may lead to minimization of intelligibility loss and quality improvement of the enhanced speech in the spectral domain, when combined with an appropriate spectral subtraction gain function. The proposed method shows better performance than the conventional one in comparative assessments. We also show that, for effective evaluation of enhanced speech, it is essential to consider the characteristics of speech quality measures.

Optimal Capacity and Allocation Distributed Generation by Minimization Operation Cost of Distribution System (배전계통 운영비용의 최소화에 의한 분산전원의 최적 용량과 위치결정)

  • 배인수;박정훈;김진오;김규호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.481-486
    • /
    • 2004
  • In operation of distribution system, $DG_s$ Distributed Generations) are installed as an alternative of extension and establishment of substations and transmission and distribution lines according to increasing power demand. In operation planning of $DG_s$, determining optimal capacity and allocation gets economical pro(it and improves power reliability. This paper proposes determining a optimal number, size and allocation of $DG_s$ needed to minimize operation cost of distribution system. Capacity of $DG_s$ (or economical operation of distribution system estimated by the load growth and line capacity during operation planning duration, DG allocations are determined to minimize total cost with power buying cost. operation cost of DG, loss cost and outage cost using GA(Genetic Algorithm).

Installation of MFC(Multiple FACTS Coordinated control) On-line System for the Spinning Reserve of a Reactive Power in Metropolitan Area (수도권 순동 무효전력 확보를 위한 FACTS 협조제어 시스템 온라인 설치)

  • Chang, Byung-Hoon;Moon, Seung-Pil;Ha, Yong-Gu;Jeon, Woong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2131-2134
    • /
    • 2010
  • In this paper, the on-line system schemes for coordinated control system of multiple FACTS were presented to enhance the voltage stability around the metropolitan areas. In order to coordinated control system of FACTS devices, MFC on-line system calculates the optimal set point(Vref, Qrev) of FACTS devices using the coordinated control algorithm with real time network data which is transferred from SCADA/EMS system. If the system is unstable after contingencies, the new operation set-point of FACTS would be determined using bus sensitivity from tangent vector at voltage instability point. Otherwise, we would determine the new operation set-point of FACTS for considering economical operation, like as active power loss minimization using Optimal Power Flow algorithm. As the test, MFC(Multiple FACTS Coordinated control) on-line system will be installed in Korea power system.

Placement and Operation of Dispersed Generation Systems using Fuzzy Goal Programming (Fuzzy Goal Programming을 응용한 분산형전원의 설치 및 운영)

  • 송현선;김규호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.146-153
    • /
    • 2004
  • This paper presents the method for the placement and operation of dispersed generator systems(DGs) using fuzzy goal programming in distribution systems. For the placement and operation of DGs the problem is formulated with reduction of search spaces and flexibility of system situations. Especially, the original objective function and constraints are transformed by fuzzy goal programming to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm.

A Study on the Comparison of Reliability for Protective Coordination of Loop Power Distributions using Communication of Circuit Breaker and Recloser (차단기와 리클로져의 통신을 이용한 루프 배전계통의 보호협조 적용시 신뢰도 비교에 관한 연구)

  • Lee, Hee-Tae;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.133-137
    • /
    • 2011
  • The purpose of smart grid is the low $CO_2$ through expansion of renewable energy. To achieve the purpose of smart grid, typical radial power distribution system will be changed to loop power distribution system. The loop power distribution system have many advantages such as low power loss, low voltage drop, and increase of connection of renewable energy. In this paper, the algorithm for minimization of interrupted section of power distribution system is proposed through communication between circuit breaker and recloser in loop power distribution system. The proposed algorithm is proved through case studies about reliability evaluation

An Assemble and Expandable Substrate Heating Apparatus for the Semiconductor Manufacturing (조립과 확장이 가능한 반도체 제조용 기판 가열 장치)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.67-71
    • /
    • 2009
  • This research is a new structure of the semiconductor substrate heating apparatus in which the assembly and expansion are possible. The fast thermo-responsive according to the direct heating structure of the heating plate layer adhering closely to the floor side of a substrate and the fast heat loss minimization can be accomplished. Moreover, the contact area of the sheath heater, which is the heating plate layer built-in heating apparatus, is increased, so that it has more heating valid area. There is no problem with the deformation interpreted in the state where it assembles the block of a several of the simulation result structure, the safety, and the stress. In addition, it is confirmed that building a large-size heating block is possible since the temperature deflection of the manufactured plate is lower than the standard value.

Development of Cooperated Control System for Multiple FACTS in KEPCO Power Systems (다기의 FACTS 기기 협조제어 시스템 개발)

  • Chang, Byung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1726-1730
    • /
    • 2008
  • In this paper, the application schemes for coordinated control system of multiple FACTS were presented to enhance the voltage stability around the metropolitan areas. In order to coordinated control of FACTS devices, f-V analysis method which is one of the indices for voltage stability was performed with real time network data which is transferred from SCADA/EMS system. If the system is unstable after contingencies, the new operation set-point of FACTS would be determined using bus sensitivity from tangent vector at voltage instability point. Otherwise, we would determine the new operation set-point of FACTS for considering economical operation, like as active power loss minimization using Optimal Power Flow algorithm. In simulation, the SCADA/EMS 2007's data are used for studying the coordinated control algorithm of multiple FACTS devices that is installed or will be installed in KOREA power system

A Section Load Management Method using Daily Load Curve in Distribution Systems (일부하 곡선을 이용한 배전계통 구간부하 관리방법)

  • Lim, Seong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.47-52
    • /
    • 2012
  • DAS(Distribution Automation System) is equipped with several software applications such as service restoration, loss minimization, and protective relay coordination. The software applications of DAS are very sensitive to the amount of section load being carried by a particular section of distribution lines. Moreover, each software application requires a different parameter of the section load according to its purpose. Therefore, This paper proposes a new section load management method using real-time measurement data of the distribution lines. In order to provide accurate data to DAS applications, this method considers section loads in terms of the relationship of power versus time. In order to establish that the proposed method is feasible, a performance-testing simulator was developed, and case studies were conducted for a modified real distribution network.