• 제목/요약/키워드: Loop-mediated isothermal amplification (LAMP)

검색결과 87건 처리시간 0.026초

Simple and Rapid Detection of Vancomycin-Resistance Gene from Enterococci by Loop-Mediated Isothermal Amplification

  • Baek, Yun Hee;Hong, Seung Bok;Shin, Kyeong Seob
    • 대한의생명과학회지
    • /
    • 제26권3호
    • /
    • pp.149-156
    • /
    • 2020
  • We developed a simple and rapid method for detecting vancomycin resistance genes, such as vanA and vanB, using loop-mediated isothermal amplification (LAMP). To identify not only vancomycin resistance genes, but also the genus Enterococcus, primers were designed for vanA, vanB, and 16S rRNA. Screening for vancomycin susceptibility in Enterococcus was performed using Etest (bioMérieux Inc). The results of the LAMP assay were compared to those of real-time RT-PCR. The optimal conditions for the LAMP assay were 65℃ for 60 min. The detection limits of the LAMP assay for vanA, and vanB were 2 × 102 copies/reaction. Compared to RT-PCR, the sensitivities and specificities of LAMP for 16S rRNA, vanA, and vanB were 100/100%, 100/100%, and 100/100%, respectively. The vanA genotype-vanB phenotype accounted for 57.5% (46/80) of the vancomycin-resistant Enterococci samples collected from 2016 to 2019. In conclusion, the LAMP assay developed in this study showed high sensitivity and specificity for vancomycin-resistant genes. Moreover, due to the simplicity and rapidity of the LAMP assay, its use can be very useful in clinical microbiology laboratories.

Detection of Acute Toxoplasmosis in Pigs Using Loop-Mediated Isothermal Amplification and Quantitative PCR

  • Wang, Yanhua;Wang, Guangxiang;Zhang, Delin;Yin, Hong;Wang, Meng
    • Parasites, Hosts and Diseases
    • /
    • 제51권5호
    • /
    • pp.573-577
    • /
    • 2013
  • A loop-mediated isothermal amplification (LAMP) assay allows rapid diagnosis of Toxoplasma gondii infection. In the present study, the LAMP assay was evaluated using blood from both naturally and experimentally infected pigs. The sensitivity of the LAMP assay was compared with that of Q-PCR. Both assays detected T. gondii in the blood of experimentally infected pigs, with 100% agreement. In infected blood samples, the parasite was detected as early as 2 days post-infection and reached a peak in 3-5 days. In 216 field serum samples, the detection rates of LAMP and Q-PCR assays were 6.9% and 7.8%, respectively. This result indicates that the sensitivity of the LAMP assay was slightly lower than that of the Q-PCR assay. However, the LAMP may be an attractive diagnostic method in conditions where sophisticated and expensive equipment is unavailable. This assay could be a powerful supplement to current diagnostic methods.

Development of reverse-transcription loop-mediated isothermal amplification assays for point-of-care testing of human influenza virus subtypes H1N1 and H3N2

  • Ji-Soo Kang;Mi-Ran Seo;Yeun-Jun Chung
    • Genomics & Informatics
    • /
    • 제20권4호
    • /
    • pp.46.1-46.7
    • /
    • 2022
  • Influenza A virus (IAV) is the most widespread pathogen causing human respiratory infections. Although polymerase chain reaction (PCR)-based methods are currently the most commonly used tools for IAV detection, PCR is not ideal for point-of-care testing. In this study, we aimed to develop a more rapid and sensitive method than PCR-based tools to detect IAV using loop-mediated isothermal amplification (LAMP) technology. We designed reverse-transcriptional (RT)-LAMP primers targeting the hemagglutinin gene. RNAs from reference H1N1 and H3N2 showed specific RT-LAMP signals with the designed primers. We optimized the reaction conditions and developed universal reaction conditions for both LAMP assays. Under these conditions, the detection limit was 50 copies for both RT-LAMP assays. There was no non-specific signal to 19 non-IAV respiratory viruses, such as influenza B virus, coronaviruses, and respiratory syncytial viruses. Regarding the reaction time, a positive signal was detected within 25 min after starting the reaction. In conclusion, our RT-LAMP assay has high sensitivity and specificity for the detection of the H1 and H3 subtypes, making it suitable for point-of-care IAV testing.

Development of a Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Nocardia salmonicida, the Causative Agent of Nocardiosis in Fish

  • Xia, Liqun;Zhang, Honglian;Lu, Yishan;Cai, Jia;Wang, Bei;Jian, Jichang
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권3호
    • /
    • pp.321-327
    • /
    • 2015
  • Nocardia salmonicida is one of the main pathogens of fish nocardiosis. The purpose of this study was to build a loop-mediated isothermal amplification (LAMP) method for the rapid and sensitive detection of N. salmonicida. A set of four primers were designed from the 16S-23S rRNA intergenic spacer region of N. salmonicida, and conditions for LAMP were optimized as incubating all the reagents for 60 min at 64℃. LAMP products were judged with agar gel electrophoresis as well as with the naked eye after the addition of SYBR Green I. Results showed the sensitivity of the LAMP assay was 1.68 × 103 CFU/ml (16.8 CFU per reaction) and 10-fold higher than that of PCR. The LAMP method was also effectively applied to detect N. salmonicida in diseased fish samples, and it may potentially facilitate the surveillance and early diagnosis of fish nocardiosis.

한우 결핵의 신속 감별진단을 위한 등온증폭법 개발 (Development of loop-mediated isothermal amplification method for the rapid and sensitive detection of bovine tuberculosis in Korea native cattle)

  • 황은숙;이태욱;정대영;조호성
    • 한국동물위생학회지
    • /
    • 제34권4호
    • /
    • pp.333-339
    • /
    • 2011
  • Loop-mediated isothermal amplification (LAMP) was developed to detect Mycobacterium tuberculosis complex (MTC) and non-tuberculous mycobacterium (NTM) genomic DNA in blood samples of Korea native cattle. A set of four primers, two outer and two inner, were designed from M. bovis and M. avium genomic DNA targeting the IS6110 and 16S rRNA gene, respectively. Based on 85 Intradermal Tuberculin Test (ITT) positive blood sample and using conventional PCR and LAMP, the agreement quotient (kappa), which measures agreement beyond chance were 0.93 (conventional PCR) and 0.97 (LAMP), respectively. The detection limit of the LAMP method was $2.0{\times}10^2$ copy/ml M. bovis and M. avium cells, compared to $2.0{\times}10^3$ copy/ml M. bovis and M. avium cells for conventional PCR. These results suggest that the LAMP is a powerful tool for rapid, sensitive, and practical detection of MTC and NTM in blood samples of Korea native cattle.

Sensitive and Rapid Detection of Giardia lamblia Infection in Pet Dogs using Loop-Mediated Isothermal Amplification

  • Li, Jie;Wang, Peiyuan;Zhang, Aiguo;Zhang, Ping;Alsarakibi, Muhamd;Li, Guoqing
    • Parasites, Hosts and Diseases
    • /
    • 제51권2호
    • /
    • pp.237-241
    • /
    • 2013
  • Giardia lamblia is recognized as one of the most prevalent parasites in dogs. The present study aimed to establish a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of G. lamblia from dogs. The fecal samples were collected and prepared for microscopic analysis, and then the genomic DNA was extracted directly from purified cysts. The concentration of DNA samples of G. lamblia were diluted by 10-fold serially ranging from $10^{-1}$ to $10^{-5}ng/{\mu}l$ for LAMP and PCR assays. The LAMP assay allows the amplification to be finished within 60 min under isothermal conditions of $63^{\circ}C$ by employing 6 oligonucleotide primers designed based on G. lamblia elongation factor 1 alpha ($EF1{\alpha}$) gene sequence. Our tests showed that the specific amplification products were obtained only with G. lamblia, while no amplification products were detected with DNA of other related protozoans. Sensitivity evaluation indicated that the LAMP assay was sensitive 10 times more than PCR. It is concluded that LAMP is a rapid, highly sensitive and specific DNA amplification technique for detection of G. lamblia, which has implications for effective control and prevention of giardiasis.

Loop-mediated isothermal amplification assay for the detection of Salmonella spp. in pig feces

  • Kim, Yong Kwan;Kim, Ha-Young;Jeon, Albert Byungyun;Lee, Myoung-Heon;Bae, You-Chan;Byun, Jae-Won
    • 대한수의학회지
    • /
    • 제54권2호
    • /
    • pp.113-115
    • /
    • 2014
  • Salmonella are causative agents of gastroenteritis and systemic disease in animals. The invA gene was selected as a target sequence of loop-mediated isothermal amplification (LAMP) assay for diagnosis of Salmonella infection. The detection limits for broth dilution, spiked feces and enrichment were $10^4$, $10^5$ and $10^2$ CFUs/mL, respectively. The LAMP assay developed in the present study may be a reliable method for detection of Salmonella spp. in pig feces.

A Reliable Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Detecting Apple stem grooving virus in Pear

  • Lee, Hyo-Jeong;Jeong, Rae-Dong
    • 식물병연구
    • /
    • 제28권2호
    • /
    • pp.92-97
    • /
    • 2022
  • Apple stem grooving virus (ASGV) is a high-risk viral pathogen that infects many types of fruit trees, especially pear and apple, and causes serious economic losses across the globe. Thus, rapid and reliable detection assay is needed to identify ASGV infection and prevent its spread. A reliable reverse transcription loop-mediated isothermal amplification (RT-LAMP) was developed, optimize, and evaluated for the coding region of coat protein of ASGV in pear leaf. The developed RT-LAMP facilitated the simple screening of ASGV using visible fluorescence and electrophoresis. The optimized reaction conditions for the RT-LAMP were 63℃ for 50 min, and the results showed high specificity and 100-fold greater sensitivity than the reverse transcription polymerase chain reaction. In addition, the reliability of the RT-LAMP was validated using field-collected pear leaves. Furthermore, the potential application of paper-based RNA isolation, combined with RT-LAMP, was also evaluated for detecting ASGV from field-collected samples. These assays could be widely applied to ASGV detection in field conditions and to virus-free certification programs.

Rapid and Sensitive Detection of Salmonella in Chickens Using Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick

  • Liu, Zhi-Ke;Zhang, Qiu-Yu;Yang, Ning-Ning;Xu, Ming-Guo;Xu, Jin-Feng;Jing, Ming-Long;Wu, Wen-Xing;Lu, Ya-Dong;Shi, Feng;Chen, Chuang-Fu
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권3호
    • /
    • pp.454-464
    • /
    • 2019
  • Salmonellosis is a highly contagious bacterial disease that threatens both human and poultry health. Tests that can detect Salmonella in the field are urgently required to facilitate disease control and for epidemiological investigations. Here, we combined loop-mediated isothermal amplification (LAMP) with a chromatographic lateral flow dipstick (LFD) to rapidly and accurately detect Salmonella. LAMP primers were designed to target the Salmonella invA gene. LAMP conditions were optimized by adjusting the ratio of inner to outer primers, $MgSO_4$ concentration, dNTP mix concentration, amplification temperature, and amplification time. We evaluated the specificity of our novel LAMP-LFD method using six Salmonella species and six related non-Salmonella strains. All six of the Salmonella strains, but none of the non-Salmonella strains, were amplified. LAMP-LFD was sensitive enough to detect concentrations of Salmonella enterica subsp. enterica serovar Pullorum genomic DNA as low as $89fg/{\mu}l$, which is 1,000 times more sensitive than conventional PCR. When artificially contaminated feed samples were analyzed, LAMP-LFD was also more sensitive than PCR. Finally, LAMP-LFD gave no false positives across 350 chicken anal swabs. Therefore, our novel LAMP-LFD assay was highly sensitive, specific, convenient, and fast, making it a valuable tool for the early diagnosis and monitoring of Salmonella infection in chickens.

Loop-Mediated Isothermal Amplification for the Detection of Xanthomonas arboricola pv. pruni in Peaches

  • Li, Weilan;Lee, Seung-Yeol;Back, Chang-Gi;Ten, Leonid N.;Jung, Hee-Young
    • The Plant Pathology Journal
    • /
    • 제35권6호
    • /
    • pp.635-643
    • /
    • 2019
  • To detect Xanthomonas arboricola pv. pruni, a loopmediated isothermal amplification (LAMP) detection method were developed. The LAMP assay was designed to test crude plant tissue without pre-extraction, or heating incubation, and without advanced analysis equipment. The LAMP primers were designed by targeting an ABC transporter ATP-binding protein, this primer set was tested using the genomic DNA of Xanthomonas and non-Xanthomonas strains, and a ladder product was generated from the genomic DNA of X. arboricola pv. pruni strain but not from 12 other Xanthomonas species strains and 6 strains of other genera. The LAMP conditions were checked with the healthy leaves of 31 peach varieties, and no reaction was detected using either the peach leaves or the peach DNA as a template. Furthermore, the high diagnostic accuracy of the LAMP method was confirmed with 13 X. arboricola pv. pruni strains isolated from various regions in Korea, with all samples exhibiting a positive reaction in LAMP assays. In particular, the LAMP method successfully detected the pathogen in diseased peach leaves and fruit in the field, and the LAMP conditions were proven to be a reliable diagnostic method for the specific detection and identification of X. arboricola pv. pruni in peach orchards.