Detection of Acute Toxoplasmosis in Pigs Using Loop-Mediated Isothermal Amplification and Quantitative PCR |
Wang, Yanhua
(State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences)
Wang, Guangxiang (State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences) Zhang, Delin (Key Laboratory of Veterinary Parasitology of Gansu Province, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences) Yin, Hong (Key Laboratory of Veterinary Public Health of the Ministry of Agriculture, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences) Wang, Meng (State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences) |
1 | Thekisoe OMM, Bazie RSB, Coronel-Servian AM, Sugimoto C, Kawazu S, Inoue N. Stability of loop-mediated isothermal amplification (LAMP) reagents and its amplification efficiency on crude trypanosome DNA templates. J Vet Med Sci 2009; 71: 471-475. DOI ScienceOn |
2 | Kong QM, Lu SH, Tong QB, Lou D, Chen R, Zheng B, Kumagai T, Wen LY, Ohta N, Zhou XN. Loop-mediated isothermal amplification (LAMP): Early detection of Toxoplasma gondii infection in mice. Parasit Vectors 2012; 5: 2. DOI |
3 | Krasteva D, Toubiana M, Hartati S, Kusumawati A, Dubremetz JF, Widada JS. Development of loop-mediated isothermal amplification (LAMP) as a diagnostic tool of toxoplasmosis. Vet Parasitol 2009; 162: 327-331. DOI ScienceOn |
4 | Lau YL, Meganathan P, Sonaimuthu P, Thiruvengadam G, Nissapatorn V, Chen Y. Specific, sensitive, and rapid diagnosis of active toxoplasmosis by a loop-mediated isothermal amplification method using blood samples from patients. J Clin Microbiol 2010; 48: 3698-3702. DOI ScienceOn |
5 | Lin ZB, Zhang YL, Zhang HS, Zhou YZ, Cao J, Zhou JL. Comparison of loop-mediated isothermal amplification (LAMP) and real-time PCR method targeting a 529-bp repeat element for diagnosis of toxoplasmosis. Vet Parasitol 2012; 185: 296-300. DOI ScienceOn |
6 | Sotiriadoua I, Karanis P. Evaluation of loop-mediated isothermal amplification for detection of Toxoplasma gondii in water samples and comparative findings by polymerase chain reaction and immunofluorescence test (IFT). Diagn Microbiol Infect Dis 2008; 62: 357-365. DOI ScienceOn |
7 | Wang YH. The study of antigenic epitopes from Toxoplasma gondii excreted/secreted antigens and surface protein 1. Chinese Academy of Agricultural Sciences. 2011, p 19-20. |
8 | Kim SK, Boothroyd JC. Stage specific expression of surface antigens by Toxoplasma gondii as a mechanism to facilitate parasite persistence. J Immunol 2005; 174: 8038-8048. DOI |
9 | Mori Y, Nagamine K, Tomita N, Notomi T. Detection of loopmediated isothermal reaction by turbidity derived from magne sium pyrophosphate formation. Biochem Biophys Res Commun 2001; 289: 150-154. DOI ScienceOn |
10 | Tomita N, Mori Y, Kanda H, Notomi T. Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nat Protoc 2008; 3: 877-882. DOI ScienceOn |
11 | Qiao YM, Guo YC, Zhang XE, Zhou YF, Zhang ZP, Wei HP, Yang RF, Wang DB. Loop-mediated isothermal amplification for rapid detection of Bacillus anthracis spores. Biotech Lett 2007; 29: 1939- 1946. DOI |
12 | Foulon W, Pinon JM, Stray-Pedersen B, Pollak A, Lappalainen M, Decoster A, Villena I, Jenum PA, Hayde M, Naessens A. Prenatal diagnosis of congenital toxoplasmosis: a multicenter evaluation of different diagnostic parameters. Am J Obstet 1999; 181: 843-847. DOI ScienceOn |
13 | Poon LLM, Wong BWY, Ma EHT, Chan KH, Chow LMC, Abeyewickreme W, Tangpukdee N, Yuen KY, Guan Y, Looareesuwan S, Peiris JS. Sensitive and inexpensive molecular test for Falciparum Malaria: detecting Plasmodium falciparum DNA directly from heattreated blood by loop-mediated isothermal amplification. Clin Chem 2006; 52: 303-306. |
14 | Nielsen HV, Lauemøller SL, Christiansen L, Buus S, Fomsgaard A, Petersen E. Complete protection against lethal Toxoplasma gondii infection in mice immunized with a plasmid encoding the SAG1 gene. Infect Immun 1999; 67: 6358-6363. |
15 | Dubey JP, Baker DG, Davis SW, Urban JF, Shen SK. Persistence of immunity to toxoplasmosis in pigs vaccinated with a non-persistent strain of Toxoplasma gondii. Am J Vet Res 1994; 55:982-987. |
16 | Wang YH, Li XR, Wang GX, Yin H, Cai XP, Fu BQ, Zhang DL. Development of an immunochromatographic strip for the rapid detection of Toxoplasma gondii circulating antigens. Parasitol Int 2011; 60: 105-107. DOI ScienceOn |
17 | Zhang HS, Thekisoe OMMM, Aboge GO, Kyan H, Yamagishi Y, Inoue N, Nishikawa Y, Zakimi S, Xuan X. Toxoplasma gondii: Sensitive and rapid detection of infection by loop-mediated isothermal amplification (LAMP) method. Exp Parasitol 2009; 122: 47-50. DOI ScienceOn |
18 | Switaj K, Master A, Skrzypczak M, Zaborowski P. Recent trends in molecular diagnostics for Toxoplasma gondii infections. Clin Microbiol Infect 2005; 11: 170-176. DOI ScienceOn |
19 | Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res 2000; E28, I-VII. |
20 | Kuboki N, Inoue N, Sakurai T, Di Cello F, Grab DJ, Suzuki H, Sugimoto C, Igarashi I. Loop-mediated isothermal amplification for detection of African trypanosomes. J Clin Microbiol 2003; 41: 5517-5524. DOI ScienceOn |
21 | Pelloux H, Weiss J, Simon J, Muet F, Fricker-Hidalgo H, Goullier- Fleuret A, Ambroise-Thomas P. A new set of primers for the detection of Toxoplasma gondii in amniotic fluid using polymerase chain reaction. FEMS Microbiol Lett 1996; 138: 11-15. DOI |
![]() |