• 제목/요약/키워드: Long wavelength infrared

검색결과 65건 처리시간 0.022초

적외선영상의 파장대역변환을 위한 추정온도 오차 보정 (Estimated Temperature Error Compensation for Wavelength-Band Conversion of Infrared Image)

  • 김영춘;안상호
    • 한국멀티미디어학회논문지
    • /
    • 제17권11호
    • /
    • pp.1270-1278
    • /
    • 2014
  • The modern infrared (IR) imaging systems use mainly one or more wavelength bands among short wavelength IR (SWIR), middle wavelength IR (MWIR), and long wavelength IR (LWIR) bands. In the process of IR image synthesis and modeling, IR image wavelength-band conversion which transforms arbitrary band image to other band one is required. The wavelength-band conversion procedure includes a temperature estimation process of an object surface. However, in this procedure, an approximated Planck's radiation equation causes errors in estimated temperature. In this paper, we propose an estimation temperature error attenuation method in IR image band conversion procedure. The estimated temperature is corrected with a slope information of radiance according to it. The corrected temperature is used for generation of the other band IR image. The verification of proposed method is demonstrated through the simulation.

열적외선 카메라용 광학계 생산성 향상에 관한 연구 (A Study on the Productivity Improvement of Thermal Infrared Camera an Optical Lens)

  • 김성용;현동훈
    • 한국생산제조학회지
    • /
    • 제18권3호
    • /
    • pp.285-293
    • /
    • 2009
  • Thermal infrared cameras have been conducted actively in various application areas, such as military, medical service, industries and cars. Because of their characteristic of sensing the radiant heat emitted from subjects in the range of long-wavelength($3{\sim}5{\mu}m$ or $8{\sim}12{\mu}m$), and of materializing a vision system, when general optics materials are used, they don't react to the light in the range of long-wavelength, and can't display their optic functions. Therefore, the materials with the feature of higher refractive index, reacting to the range of long-wavelength, are to be used. The kinds of materials with the characteristic of higher refractive index are limited, and their features are close to those of metals. Because of these metallic features, the existing producing method of optical systems were direct manufacturing method using grinding method or CAD/CAM, which put limit on productivity and made it difficult to properly cope with the increasing demand of markets. GASIR, a material, which can be molded easily, was selected among infrared ray optics materials in this study, and the optical system was designed with two Aspheric lenses. Because the lenses are molded in the environment of high temperature and high pressure, they require a special metallic pattern. The metallic pattern was produced with materials with ultra hardness that can stand high temperature and high pressure. As for the lens mold, GMP(Glass Molding Press) of the linear transfer method was used in order to improve the productivity of optical systems for thermal infrared cameras, which was the goal of this paper.

  • PDF

저항성 홀배열이 적용된 볼로미터의 적외선 흡수 특성 변화 (Variation in IR Absorption Characteristics of a Bolometer by Resistive Hole-array Patterns)

  • 김태현;오재섭;박종철;김희연;이종권
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.306-310
    • /
    • 2018
  • In order to develop a highly sensitive infrared sensor, it is necessary to develop techniques for decreasing the rate of heat absorption and the transition of the absorption wavelength to a longer wavelength, both of which can be induced by decreasing the pixel size of the bolometer. Therefore, in this study, $1{\mu}m$ hole-arrays with a subwavelength smaller than the incident infrared wavelength were formed on the amorphous silicon-based microbolometer pixels in the absorber, which consisted of a TiN absorption layer, an a-Si resistance layer and a SiNx membrane support layer. We demonstrated that it is possible to reduce the thermal time constant by 16% relative to the hole-patternless bolometer, and that it is possible to shift the absorption peak to a shorter wavelength as well as increase absorption in the $4-8{\mu}m$ band to compensate for the infrared long-wavelength transition. These results demonstrate the potential for a new approach to improve the performance of high-resolution microbolometers.

Wavelength selection by loading vector analysis in determining total protein in human serum using near-infrared spectroscopy and Partial Least Squares Regression

  • Kim, Yoen-Joo;Yoon, Gil-Won
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.4102-4102
    • /
    • 2001
  • In multivariate analysis, absorbance spectrum is measured over a band of wavelengths. One does not often pay attention to the size of this wavelength band. However, it is desirable that spectrum is measured at only necessary wavelengths as long as the acceptable accuracy of prediction can be met. In this paper, the method of selecting an optimal band of wavelengths based on the loading vector analysis was proposed and applied for determining total protein in human serum using near-infrared transmission spectroscopy and PLSR. Loading vectors in the full spectrum PLSR were used as reference in selecting wavelengths, but only the first loading vector was used since it explains the spectrum best. Absorbance spectra of sera from 97 outpatients were measured at 1530∼1850 nm with an interval of 2 nm. Total protein concentrations of sera were ranged from 5.1 to 7.7 g/㎗. Spectra were measured by Cary 5E spectrophotometer (Varian, Australia). Serum in the 5 mm-pathlength cuvette was put in the sample beam and air in the reference beam. Full spectrum PLSR was applied to determine total protein from sera. Next, the wavelength region of 1672∼1754 nm was selected based on the first loading vector analysis. Standard Error of Cross Validation (SECV) of full spectrum (1530∼l850 nm) PLSR and selected wavelength PLSR (1672∼1754 nm) was respectively 0.28 and 0.27 g/㎗. The prediction accuracy between the two bands was equal. Wavelength selection based on loading vector in PLSR seemed to be simple and robust in comparison to other methods based on correlation plot, regression vector and genetic algorithm. As a reference of wavelength selection for PLSR, the loading vector has the advantage over the correlation plot since the former is based on multivariate model whereas the latter, on univariate model. Wavelength selection by the first loading vector analysis requires shorter computation time than that by genetic algorithm and needs not smoothing.

  • PDF

Optical Properties of Long Wave Infrared Spoof Plasmon using Hexagonal Periodic Silver Hole Arrays

  • Lee, Byungwoo;Kwak, Hoe Min;Kim, Ha Sul
    • Applied Science and Convergence Technology
    • /
    • 제25권2호
    • /
    • pp.42-45
    • /
    • 2016
  • A two-dimensional metal hole array (2DMHA) structure is fabricated by conventional photo-lithography and electron beam evaporation. The transmittance of the 2DMHA is measured at long wave infrared (LWIR) wavelengths (${\lambda}{\sim}10$ to $24{\mu}m$). The 2DMHA sample shows transmittance of 70 and 67% at $15.4{\mu}m$ due to plasmonic resonance with perforated silver and gold thin films, respectively, under surface normal illumination at LWIR wavelengths. The measured infrared spectrum is separated into two peaks when the size of the hole becomes larger than a half-pitch of the hole array. Six degenerated plasmon modes (1,0) at the metal/Si surface split to three modes at an incident beam angle of $45^{\circ}$ with respect to the surface normal direction, and wavelength shifts of the transmitted spectrum are observed in a red shift and blue shift at the same time.

Design and Performance Verification of a LWIR Zoom Camera for Drones

  • Kwang-Woo Park;Jonghwa Choi;Jian Kang
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.354-361
    • /
    • 2023
  • We present the optical design and experimental verification of resolving performance of a 3× long wavelength infrared (LWIR) zoom camera for drones. The effective focal length of the system varies from 24.5 mm at the wide angle position to 75.1 mm at the telephoto position. The design specifications of the system were derived from ground resolved distance (GRD) to recognize 3 m × 6 m target at a distance of 1 km, at the telephoto position. To satisfy the system requirement, the aperture (f-number) of the system is taken as F/1.6 and the final modulation transfer function (MTF) should be higher than 0.1 (10%). The measured MTF in the laboratory was 0.127 (12.7%), exceeds the system requirement. Outdoor targets were used to verify the comprehensive performance of the system. The system resolved 4-bar targets corresponding to the spatial resolution at the distance of 1 km, 1.4 km and 2 km.

Transfer Efficiency of Underwater Optical Wireless Power Transmission Depending on the Operating Wavelength

  • Kim, Sung-Man;Kwon, Dongyoon
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.571-575
    • /
    • 2020
  • Optical wireless power transmission (OWPT) is a good candidate for long-distance underwater wireless power transmission. In this work we investigate the transmission efficiency of underwater OWPT, depending on the operating wavelength. We consider four operating wavelengths: infrared, red, green, and blue. We also consider the cases of pure water and sea water for the working conditions. Our results show that it is necessary to select the operating wavelength of underwater OWPT according to the transmission distance and water type of the target application.

Far infrared를 이용한 생체정보 인터페이싱에 대한 연구 (Research of human body information interfacing with Far infrared and application to physical therapy)

  • 박래준;김재윤
    • The Journal of Korean Physical Therapy
    • /
    • 제13권3호
    • /
    • pp.509-527
    • /
    • 2001
  • The Sun's ray is composed of Infrared(49%), Visible light(40%) and Ultra violet(11%), however the ray getting to the earth is FIR(Far infrared; 60%), IR(Infrared; 20%), and UV(Ultra Violet; 20%). Human beings has utilized FIR already from time immemorial. Hershel found out Infrared for the first time. in the Industrial Revolution the Infrared and FIR had been begun to use making products. In these days, with contemporary science FIR would be begun to clear up the implication in the human body and organic compound. IR classified by wavelength three parts NlR, MIR, FIR. There is FIR which is radiated from healthy human body the wave length is 8-l4m. The human body is composed of proteins which get easily changed by a thermal factor (about 42 $^{\circ}$C over). FIR with low temperature can deeply penetrate on the human body composed things without troublesomes, since FIR has effectively operated on the human body at low temperature (35-40 $^{\circ}$C). When FlR penetrated on the human body. it would inhibit the abnormal genes and cells expression, and then information of DNA and RNA would be reexpressed for arranging DNA and RNA abnormal state. As FlR's receptors in the body, it could be presumed that N-glycosyl linkage of purine and deoxyribose, RNA splicing process, and Heat shock protein. To take the FIR which was a optimized wavewlength and strength, at first, we induced the characteristic algorithm and the computerized programing. Then we formed that the formular of optimized FIR with physical, mathematical logic and theory. especially, Plank, Kirchhoff, Wien, Stefan-Boltzmann's logic and law. In the long run, the formular was induced with integration mathematical, since we had to know the molecular wavelength. Based on the induced formular as above, we programmed the optimized FlR radiating computerized program. In this research, we designed the eletronic circuit f3r interfacing with human body to diagnosis and treatment with FIR sensor which radiated FIR wavelength optimized.

  • PDF

열적외선 이미지를 이용한 영상 처리 (Image Processing using Thermal Infrared Image)

  • 정병조;장성환
    • 한국산학기술학회논문지
    • /
    • 제10권7호
    • /
    • pp.1503-1508
    • /
    • 2009
  • 본 논문은 열적외선 카메라 이미지를 영상 처리 기법을 활용하여 실시간으로 구현하는데 그 목적이 있다. 열적외선 영상 데이터는 온도의 변화에 따라 Hot Mapping, Cool Mapping, Rainbow Mapping을 하였으며, 열적외선 이미지의 명암대비 기능을 알아보기 위해 히스토그램 영상처리 기법을 사용하였고, 물체의 구분을 위해서 열적외선 이미지의 에지 부분을 추출하였다. 또한 이미지에서 온도를 추출해 내기 위해 이미지 정보 프로그램을 만들어 온도를 측정할 수 있었다.

MoO3 기반 실리콘 이종접합 IR 영역 광검출기 개발 (MoO3/p-Si Heterojunction for Infrared Photodetector)

  • 박왕희;김준동;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제30권8호
    • /
    • pp.525-529
    • /
    • 2017
  • Molybdenum oxide ($MoO_3$) offers pivotal advantages for high optical transparency and low light reflection. Considering device fabrication, n-type $MoO_3$ semiconductor can spontaneously establish a junction with p-type Si. Since the energy bandgap of Si is 1.12 eV, a maximum photon wavelength of around 1,100 nm is required to initiate effective photoelectric reaction. However, the utilization of infrared photons is very limited for Si photonics. Hence, to enhance the Si photoelectric devices, we applied the wide energy bandgap $MoO_3$ (3.7 eV) top-layer onto Si. Using a large-scale production method, a wafer-scale $MoO_3$ device was fabricated with a highly crystalline structure. The $MoO_3/p-Si$ heterojunction device provides distinct photoresponses for long wavelength photons at 900 nm and 1,100 nm with extremely fast response times: rise time of 65.69 ms and fall time of 71.82 ms. We demonstrate the high-performing $MoO_3/p-Si$ infrared photodetector and provide a design scheme for the extension of Si for the utilization of long-wavelength light.