• 제목/요약/키워드: Long cable

검색결과 498건 처리시간 0.019초

개폐식 방사형 케이블 지붕 시스템의 역학적 특성 (Mechanical Characteristics of Retractable Radial Cable Roof Systems)

  • 박강근;이동우;최동일
    • 한국공간구조학회논문집
    • /
    • 제17권2호
    • /
    • pp.21-32
    • /
    • 2017
  • The objective of this study is to analysis the mechanical characteristics on the geometric nonlinear behavior of radial cable roof systems for long span retractable cable roof structures. The retractable roof is designed as a full control system to overcome extreme outdoor environments such as extreme hot or cold weather, strong wind or sunlight, and the cable roof greatly can reduce roof weight compared to other rigid structural system. A retractable cable roof system is a type of structures in which the part of entire roof can be opened and closed. The radial cable roof is an effective structural system for large span retractable roofs, the outer perimeter of the roof is a fixed membrane roof and the middle part is a roof that can be opened and closed. The double arrangement cables of a radial cable truss roof system with reverse curvature works more effectively as a load bearing cables, the cable system can carry vertical load in up and downward direction. In this paper, to analyze the mechanical characteristics of a radial cable roof system with central posts, the authors will investigate the tensile forces of bearing cables, stabilized cables, ring cables, and the deflection of roof according to the height of the post or hub that affects the sag ratio of cable truss. The tensile forces of the cables and the deflection of the roof are compared for the cases when the retractable roof is closed and opened.

Long-term monitoring of super-long stay cables on a cable-stayed bridge

  • Shen, Xiang;Ma, Ru-jin;Ge, Chun-xi;Hu, Xiao-hong
    • Wind and Structures
    • /
    • 제27권6호
    • /
    • pp.357-368
    • /
    • 2018
  • For a long cable-stayed bridge, stay cables are its most important load-carrying components. In this paper, long-term monitoring of super-long stay cables of Sutong Bridge is introduced. A comprehensive data analysis procedure is presented, in which time domain and frequency domain based analyses are carried out. In time domain, the vibration data of several long stay cables are firstly analyzed and the standard deviation of the acceleration of stay cables, and its variation with time are obtained, as well as the relationship between in-plane vibration and out-plane vibration. Meanwhile, some vibrations such as wind and rain induced vibration are detected. Through frequency domain analysis, the basic frequencies of the stay cables are identified. Furthermore, the axial forces and their statistical parameters are acquired. To investigate the vibration deflection, an FFT-based decomposition method is used to get the modal deflection. In the end, the relationship between the vibration amplitude of stay cables and the wind speed is investigated based on correlation analysis. Through the adopted procedure, some structural parameters of the stay cables have been derived, which can be used for evaluating the component performance and corresponding management of stay cables.

Nonlinear dynamic performance of long-span cable-stayed bridge under traffic and wind

  • Han, Wanshui;Ma, Lin;Cai, C.S.;Chen, Suren;Wu, Jun
    • Wind and Structures
    • /
    • 제20권2호
    • /
    • pp.249-274
    • /
    • 2015
  • Long-span cable-stayed bridges exhibit some features which are more critical than typical long span bridges such as geometric and aerodynamic nonlinearities, higher probability of the presence of multiple vehicles on the bridge, and more significant influence of wind loads acting on the ultra high pylon and super long cables. A three-dimensional nonlinear fully-coupled analytical model is developed in this study to improve the dynamic performance prediction of long cable-stayed bridges under combined traffic and wind loads. The modified spectral representation method is introduced to simulate the fluctuating wind field of all the components of the whole bridge simultaneously with high accuracy and efficiency. Then, the aerostatic and aerodynamic wind forces acting on the whole bridge including the bridge deck, pylon, cables and even piers are all derived. The cellular automation method is applied to simulate the stochastic traffic flow which can reflect the real traffic properties on the long span bridge such as lane changing, acceleration, or deceleration. The dynamic interaction between vehicles and the bridge depends on both the geometrical and mechanical relationships between the wheels of vehicles and the contact points on the bridge deck. Nonlinear properties such as geometric nonlinearity and aerodynamic nonlinearity are fully considered. The equations of motion of the coupled wind-traffic-bridge system are derived and solved with a nonlinear separate iteration method which can considerably improve the calculation efficiency. A long cable-stayed bridge, Sutong Bridge across the Yangze River in China, is selected as a numerical example to demonstrate the dynamic interaction of the coupled system. The influences of the whole bridge wind field as well as the geometric and aerodynamic nonlinearities on the responses of the wind-traffic-bridge system are discussed.

사장교의 동특성분석에 관한 실험적 연구 (Experimental Study on Dynamic Characteristics of Cable-Stayed Bridge)

  • 황학주;김상효;전귀현;박기태;신주환
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 1994
  • Recently, cable-supported long-span bridge are widely constructed due to improved quality of cable and development of design and construction techniques. In this study, an existing cable-stayed bridge, Dolsan Bridge, has been evaluated based on the cable forces measured using vibration method. And the finite element model using in this study for the dynamic analysis has been found to be quite comparable with dynamic mode shapes and natural frequencies estimated from experimental data induced by ambient traffic excitations.

  • PDF

THE STUDY OF THE DIFFERENCE BETWEEN GALLOPING CABLE AND SUSPENSION BRIDGE CABLE

  • Oh, Hye-Young
    • 한국수학교육학회지시리즈B:순수및응용수학
    • /
    • 제4권1호
    • /
    • pp.35-46
    • /
    • 1997
  • We consider the common and different results between the oscillation of galloping cable and the oscillation of suspension bridge cable through the long-term behavior. Numerical results are presented by using the second-order Runge-Kutta method under various initial conditions. There appeared to be nonlinear forms. Periodicity, symmetry, and longitudinality are differently appeared in two kinds of cables.

  • PDF

Condition assessment of stay cables through enhanced time series classification using a deep learning approach

  • Zhang, Zhiming;Yan, Jin;Li, Liangding;Pan, Hong;Dong, Chuanzhi
    • Smart Structures and Systems
    • /
    • 제29권1호
    • /
    • pp.105-116
    • /
    • 2022
  • Stay cables play an essential role in cable-stayed bridges. Severe vibrations and/or harsh environment may result in cable failures. Therefore, an efficient structural health monitoring (SHM) solution for cable damage detection is necessary. This study proposes a data-driven method for immediately detecting cable damage from measured cable forces by recognizing pattern transition from the intact condition when damage occurs. In the proposed method, pattern recognition for cable damage detection is realized by time series classification (TSC) using a deep learning (DL) model, namely, the long short term memory fully convolutional network (LSTM-FCN). First, a TSC classifier is trained and validated using the cable forces (or cable force ratios) collected from intact stay cables, setting the segmented data series as input and the cable (or cable pair) ID as class labels. Subsequently, the classifier is tested using the data collected under possible damaged conditions. Finally, the cable or cable pair corresponding to the least classification accuracy is recommended as the most probable damaged cable or cable pair. A case study using measured cable forces from an in-service cable-stayed bridge shows that the cable with damage can be correctly identified using the proposed DL-TSC method. Compared with existing cable damage detection methods in the literature, the DL-TSC method requires minor data preprocessing and feature engineering and thus enables fast and convenient early detection in real applications.

CFRP 케이블의 거동에 대한 연구 (A Study on the Behavior of CFRP Cable)

  • 박재균;홍기증
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.457-462
    • /
    • 2007
  • The high tensile strength of steel cable enabled the development of long span cable bridges which that a better tensile element can break the limitation of current bridge design. A carbon fiber has at least strength as steel cable and is very light material relatively. Due to its characteristics. commercial carbon fiber cables are already used in place of steel prestress tendons. This study proposes a parallel carbon fiber(CF) cable for cable based on NPWS and CFCC cables. Static and nonlinear analyses reveal that the CF cable develops much less stress than the NPWS cable cyclic loads.

  • PDF

345kV XLPE 장거리 지중송전선로 준공 (COMPLETION OF 345kV LONG DISTANCE XLPE CABLE)

  • 이인호;이승현;허회덕;진용국;이전선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.364-366
    • /
    • 2003
  • 345kV XLPE Cable system was constructed between Yeongseo-Yeongdeunpo at first in Korea. XLPE cable have the advantage of OF cable. it is to raise the power transmission capacity and reduce the power loss and expenses. We also applied many new technology in this project at first. One is pre-fabricated joint which can be easily assembled in the field without any hand-skill, another is PD(Partial Discharge) test for after laying test. Especially, PD measurement for after-laying test was performed to evaluate the quality of the cable joint and termination. Through the good experience of this project, we have gotten the international competitiveness of power business.

  • PDF

Empirical formulas to estimate cable tension by cable fundamental frequency

  • Ren, Wei-Xin;Chen, Gang;Hu, Wei-Hua
    • Structural Engineering and Mechanics
    • /
    • 제20권3호
    • /
    • pp.363-380
    • /
    • 2005
  • The cable tension plays an important role in the construction, assessment and long-term health monitoring of cable structures. The cable vibration equation is nonlinear if cable sag and bending stiffness are included. The engineering implementation of a vibration-based cable tension evaluation is mostly carried out by the simple taut string theory. However, the simple theory may cause unacceptable errors in many applications since the cable sag and bending stiffness are ignored. From the practical point of view, it is necessary to have empirical formulas if they are simple and yet accurate. Based on the solutions by means of energy method and fitting the exact solutions of cable vibration equations where the cable sag and bending stiffness are respectively taken into account, the empirical formulas are proposed in the paper to estimate cable tension based on the cable fundamental frequency only. The applicability of the proposed formulas is verified by comparing the results with those reported in the literatures and with the experimental results carried out on the stay cables in the laboratory. The proposed formulas are straightforward and they are convenient for practical engineers to fast estimate the cable tension by the cable fundamental frequency.

Development of automatic system for evaluating the stress redistribution in structural members of a steel cable-stayed bridge due to cable stress relaxation

  • Hong, Tien-Thang;Kim, Jung J.;Thai, Duc-Kien;Kim, Seung-Eock
    • Steel and Composite Structures
    • /
    • 제44권6호
    • /
    • pp.753-768
    • /
    • 2022
  • In this study, a graphical automatic system is developed in order to investigate the stress redistribution of structural members in a steel cable-stayed bridge. The generalized Maxwell model is selected for stress relaxation estimation, and it is carefully verified and applied to all the cable members of a steel cable-stayed bridge to investigate its stress relaxation. A set of stress relaxation parameters in all cables is determined using the fmincon optimization function. The stress redistribution of the steel cable-stayed bridge is then analyzed using ABAQUS. To shorten the investigation time, all the aforementioned phases are built up to be an automatic system. The automatic system is then employed to investigate the effect of cable cross-section areas and girder spans on stress redistribution. The findings from these studies show that the initial tension in the cables of a steel cable-stayed bridge should be kept to less than 55% of the cable's ultimate strength to reduce the effect of cable stress relaxation. The cable space in a steel cable-stayed bridge should be limited to 15,000 mm to minimize the effect of cable stress relaxation. In comparison to other structural members of a steel cable-stayed bridge, the girders experience a significant stress redistribution.