• Title/Summary/Keyword: Loading out

Search Result 2,301, Processing Time 0.039 seconds

Stability dip, the obstacle of early loading protocol, how can it be figured out? (임상가를 위한 특집 2 - Early loading의 난제 stability dip, 어떻게 극복할 것인가?)

  • Park, Chang-Joo
    • The Journal of the Korean dental association
    • /
    • v.51 no.4
    • /
    • pp.198-203
    • /
    • 2013
  • Nowadays, it seems like that the concept of the early loading protocol has been intruded between the concept of the immediate loading supported by advanced clinicians and the concept of the conventional loading supported by the prudent clinicians. In particular, the stability dip, which is found to occur usually at 4~6 weeks after dental implant placement because the decrease of the primary mechanical stability is not compensated by the increase of the secondary biologic stability, is frequently pointed out as one of the major causes of early loading failure. In this article, based on our recent clinical investigation about the crestal bone preservation effect of the early loaded NanoTite$^{TM}$ Tapered Certain Prevail$^{(R)}$ (Biomet 3i, USA), the concept of the early loading is revisited. In addition, various methods to overcome the stability dip are reviewed as the oral and maxillofacial surgeon's view point.

Experimental Study of Bond Stress-Slip Behavior under Repeated Loading (반복하중 하에서 부착응력-슬립 거동 실험적 연구)

  • 오병환;김세훈;김지상;신용석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.215-218
    • /
    • 2003
  • To analyze a bond stress-slip behavior between a reinforcing bar and concrete under repeated loading, pull-out fatigue test was performed. Major variables were repeated stress levels and cycle numbers. Test specimen was taken repeated constant amplitude loading before it was fractured by pull-out test. Increments of bond strength and slip according to repeated stress level and cycle numbers were analyzed. On the basis of test results, Local bond stress-slip relationship under repeated loading were formulated

  • PDF

Blast behavior of steel infill panels with various thickness and stiffener arrangement

  • Lotfi, Saeid;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.65 no.5
    • /
    • pp.587-600
    • /
    • 2018
  • Infill panel is the first element of a building subjected to blast loading activating its out-of-plane behavior. If the infill panel does not have enough ductility against the loading, it breaks and gets damaged before load transfer and energy dissipation. As steel infill panel has appropriate ductility before fracture, it can be used as an alternative to typical infill panels under blast loading. Also, it plays a pivotal role in maintaining sensitive main parts against blast loading. Concerning enough ductility of the infill panel out-of-plane behavior, the impact force enters the horizontal diaphragm and is distributed among the lateral elements. This article investigates the behavior of steel infill panels with different thicknesses and stiffeners. In order to precisely study steel infill panels, different ranges of blast loading are used and maximum displacement of steel infill under such various blast loading is studied. In this research, finite element analyses including geometric and material nonlinearities are used for optimization of the steel plate thickness and stiffener arrangement to obtain more efficient design for its better out-of-plane behavior. The results indicate that this type of infill with out-of-plane behavior shows a proper ductility especially in severe blast loadings. In the blasts with high intensity, maximum displacement of infill is more sensitive to change in the thickness of plate rather the change in number of stiffeners such that increasing the number of stiffeners and the plate thickness of infill panel would decrease energy dissipation by 20 and 77% respectively. The ductile behavior of steel infill panels shows that using infill panels with less thickness has more effect on energy dissipation. According to this study, the infill panel with 5 mm thickness works better if the criterion of steel infill panel design is the reduction of transmitted impulse to main structure. For example in steel infill panels with 5 stiffeners and blast loading with the reflected pressure of 375 kPa and duration of 50 milliseconds, the transmitted impulse has decreased from 41206 N.Sec in 20 mm infill to 37898 N.Sec in 5 mm infill panel.

Wheel Off-loading test procedure and result (단차 상태 차량 윤중 감소율 시험 절차 및 결과)

  • 김진태;이원상
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.857-862
    • /
    • 2002
  • The bogie, when run on the twist track develops the wheel off-loading factor. This will be comfirmed by testing under different loading conditions and air springs inflated and deflated in all conditions. Under the most extreme twist track condition, EMU (Electrical Multiple Unit) shall not over the wheel off-loading requirement 60% defined on UIC / ORE report. This paper describes the wheel off-loading test procedure according to UIC / ORE and test result of DMRC EMU of INDIA carried out to find out to meet the requirement defined in UIC / ORE.

  • PDF

Failure analysis of composite plates under static and dynamic loading

  • Ray, Chaitali;Majumder, Somnath
    • Structural Engineering and Mechanics
    • /
    • v.52 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • The present paper deals with the first ply failure analysis of the laminated composite plates under various static and dynamic loading conditions. Static analysis has been carried out under patch load and triangular load. The dynamic failure analysis has been carried out under triangular pulse load. The formulation has been carried out using the finite element method and a computer code has been developed. The first order shear deformation theory has been applied in the present formulation. The displacement time history analysis of laminated composite plate has been carried out and the results are compared with those published in literature to validate the formulation. The first ply failure load for laminated composite plates with various lamination schemes under static and dynamic loading conditions has been calculated using various failure criteria. The failure index-time history analysis has also been carried out and presented in this paper.

A Study on Behavior of Horizontal Pull-out Loaded suction pile in Sands (사질토지반에서 수평인발하중을 받는 석션말뚝에 관한 연구)

  • Kim, Jin-Bok;Park, Joung-Un;Jin, Hong-Min;Kwon, Oh-Kyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1120-1131
    • /
    • 2010
  • In this thesis the model tests were performed to the horizontal pull-out characteristics of a suction pile subjected to a pull in sands. For this model tests, soil conditions ($D_r$=65), three pile diameters (D=100, 150, 200mm) and five loading points (h/L=0, 0.25, 0.5, 0.75, 1) were changed. And the experimental results were also compared with those by the theoretical methods. The results by the experimental and theoretical analysis are as follows. The ultimate horizontal pull-out resistance by the model test increased as the loading point (h/L) moved downwards from the pile top, and the maximum value reached at the h/L=0.75. The theoretical ultimate horizontal pull-out resistance by Broms(1964) and Hong(1984) agreed well with that by the model test at h/L=0 and 0.25, but their results overestimated the experimental result at lower part of pile and the differences between the theoretical and experimental results were of great. While the horizontal loading applied at the upper part of pile, the pile moved to the horizontal direction with rotating clockwise. As the loading point moved downwards from the pile top, the rotating angle of pile was smaller.

  • PDF

Additional Damage of A17075-T651 under $90^{\circ}C$ Out-of phase Biaxial Loading from Crystal Structure Dependence ($90^{\circ}C$위상차의 이축하중 하에서 A17075-T651의 부가적 손상에 관한 결정구조 의존성에 관한 연구)

  • Lee, Hyun-Woo;Oh, Se-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.104-111
    • /
    • 1997
  • Accounting for the additional damages come out from non-proportional loading path effect, material damage according to crystal structure dependence was studied. Microscopic observations of damaged material by SEM(Scanning Electron Microscope) showed crystal structure dependence. Biaxial in-phase loaded specimens showed the slips of same direction, which pararell each other, but biaxial 90.deg. out-of-phase loaded specimens showed multiply crossed slips. S. H. Doong and D. F. Socie reported that wavy/planar or planar slip material showed the increase in the cyclic hardening level during non-proportional cycling. From these results, the additional hardening and non-proportional loading effects were related with slip mechanism, and the slip mechanism was related with crystal structure. In the present study, a damage mechanism which accounts for the non-proportional loading effect from crystal structure dependence was considered and applied to A17075-T651.

An Experimental Study on the Design of Dobby Hook for Repeated Loading Force (반복하중을 받는 Dobby Hook의 설계에 관한 실험적 연구)

  • Kim, Jong-Su;Lee, Gyu-Jeong;Lee, Tae-Se
    • 한국기계연구소 소보
    • /
    • s.20
    • /
    • pp.115-118
    • /
    • 1990
  • Hook of Dobby is a important part of shedding device, which must be endured the repeated loading force. In this paper, experiment on various mechanical characteristics; measurement of loading force were carried out, and compared the experimental values with results of Finite Element Method.

  • PDF

Characteristic of Vertical Stress in Sandy Soil according to Loading Types (재하방법에 따른 사질토 지반의 연직응력 특성)

  • Nam, Hyo-Seok;Lee, Sang-Ho;Kwon, Moo-Nam
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.83-90
    • /
    • 2009
  • This study was carried out to evaluate the vertical stress properties in sandy soil according to changes of loading type in soil bin compacted three layers. The following conclusions and comparisons have been made based on careful analysis from theoretical and experimental methods. : When sandy soil subjected to cycle-loading, compression of foundation and diffusion of vertical stress increment(${\Delta}{\sigma}_2$) were influenced by magnitude of loading plate. When sandy soil subjected to reloading after removing of pre-loading, the distribution of ${\Delta}{\sigma}_2$ depth at one time of loading plate width was different from its distribution at more deep point cause of load hysteresis, so in case of design of structure, the effect of ${\Delta}{\sigma}_2$ as depth must be considered. The increment of vertical stress will be different as loading condition and foundation depth, the loading condition must be considered in case of structure design.

Bi-Axial Alternate Cyclic Loading Test of Rectangular Reinforced Concrete Columns (이축방향 교번반복하중을 받는 구형 철근콘크리트교각의 거동특성 시험)

  • 김재관;김익현;이재호;김남식
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.323-328
    • /
    • 2001
  • The behavior of bridge column under multi-directional loading as well as uni-directional loading need to be studied because bridge columns will be subjected to the multi-directional cyclic loading during a strong earthquake. To evaluate the capacity of columns, uni-axial cyclic loading tests and bi-axial alternate cyclic loading tests were carried out. The number of cycles of alternate bi-axial loading were determined considering the ratio of natural frequencies in two orthogonal directions. From the test results, strength degradation and ductility reduction were observed in biaxial loading conditions. Their rates were found to be more rapid in the loading pattern that was determined considering the different natural frequencies.

  • PDF