• 제목/요약/키워드: Loading Force

검색결과 1,281건 처리시간 0.025초

유한요소해석을 이용한 3축 힘 촉각센서 설계 및 해석 (Design and analysis of tactile sensor for tri-axial force measurement using FEM)

  • 조운기;김종호;강대임;이억섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.865-870
    • /
    • 2001
  • A sensing element for tri-axial force measurement, unit sensor of tactile sensor, was designed and evaluated by using finite element method (ANSYS). The sensor has a maximum force range of ${\pm}10$ N in the x, y, and z direction. Optimal cell structures and piezoresistor positions were determined by the strain distribution obtained from finite element analysis. Finally three Wheatstone birdge circuits were arranged and verified by $F_x$, $F_y$, and $F_z$ loading conditions. In addition, in case of sensing element subjected to thermal loading, the outputs of three bridge circuits were also evaluated.

  • PDF

2열 외부가압 공기 저어널 베어링에서 급기구 위치에 따른 동적계수에 관한 실험적 연구 (An Experimental Study on the Dynamic Coefficient According to the Source Positions in Externally Pressurized Air-lubricated Journal Bearing with Two Row Sources)

  • 이종렬;이준석;성승학;이득우
    • Tribology and Lubricants
    • /
    • 제17권6호
    • /
    • pp.476-481
    • /
    • 2001
  • This paper has been presented the hydrodynamic effect by the journal speed, eccentricity and source positions in order to overcome the defects of air bearing such as low stiffness and damping coefficient. Choosing the two row source position of air bearing is different from existed investigations in the side of pressure distribution of air film because of the high speed of journal and the wedge effects by the eccentricity. These optimal chooses of the two row source positions enable us to improve the performance of the film reaction force and loading force as making the high speed spindle. In this paper, The pressure behavior in theory of air film according to the eccentricity of journal and the source positions analyzed. The theoretical analysis have been identified by experiments. The results of investigated characteristics may be applied to precision devices like ultra-precision grinding machine and ultra high speed milling.

2열 외부가압 공기 저어널 베어링에서 공기 급기구 위치에 따른 동적계수에 관한 실험적 연구 (A Expermental Study on the Dynamic Coefficients according to the Source Positions in Externally Pressurised Air-lubricated Journal Bearing with Two Row Sources)

  • 이종렬;이준석;성승학;이득우
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.231-235
    • /
    • 2001
  • This paper has been presented the dynamic effect by the journal speed. eccentricity and source positions in order to overcome the defects of air bearing such as low stiffness and damping coefficient. Choosing the two row source position of air bearing is different from previous investigations in the side of pressure distribution of air film by the wedge effects. These optimal chooses of the two row source positions enable us to improve the performance of the film reaction force and loading force as making the high speed spindle. The results of investigated characteristics may be applied to precision devices like ultra-precision grinding machine and ultra high speed milling.

  • PDF

재하속도가 H-형강 기둥부재의 횡방향 거동에 미치는 영향 (Loading Rate Effect on the Lateral Response of H-Shape Steel Column)

  • 박민석;김철영;한종욱;채윤병
    • 대한토목학회논문집
    • /
    • 제41권6호
    • /
    • pp.637-644
    • /
    • 2021
  • 대부분 동적 성능 평가는 반복 가력 실험을 수행함으로써 구조물의 동적 응답을 평가할 수 있다. 일반적으로 강재는 재하속도 의존성 재료로 알려져 있으며 기둥 부재의 횡방향인 수평방향 가력 시 기둥 부재의 축력인 수직하중이 작용하면 부재의 응답에 영향을 미친다. 하지만, 강재 기둥 구조물의 실험 시 수평 및 수직하중을 동시에 제어하는 것이 어려워 관련 연구는 부족한 실정이다. 본 연구에서는 기둥 부재를 ATS Compensator와 FLB 시스템을 이용하여 수평 및 수직하중을 고속으로 제어하였다. 실험은 H-형 구조용 압연강재인 SS275을 이용하여 수직 하중을 제어하면서 여러 속도로 단조 및 반복 가력 실험을 수행하고 부재의 항복 하중을 비교하였다. 또한, 유한요소해석 시 재하속도에 따라 새로운 항복 응력을 제안하고 수치해석을 통해 비교하였다.

가력유형별 군중하중의 크기에 관한 실험적 연구 (The Size of Crowd Pressure According to Loading Patterns)

  • 김진식;신윤호;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.128-129
    • /
    • 2016
  • This study is to categorize the loading of multiple persons on a vertical building elements into three types to test the size of crowd pressure under each loading patterns. The loading patterns is divided under the combination of loading method and loading persons. The loading method is categorized into the method of instantaneous loading of hand on a force plate and the method of continuous loading. The loading persons has been composed of 1~5 persons under the loading patterns. The loading patterns is also divided into lateral loading, longitudinal loading, and agglomeration loading. The subject group has been composed of 12 males in 20s. The load measurement device(size 1800×600×36mm, capacity 20kN, rigidity 28kN/cm) has been designed and manufactured directly. To eliminate the difference of individual, the size of crowd pressure has been converted into the strength to weight ratio (maximum load/weight) for computation. The strength to weight ratio in lateral loading was about 0.91 under instantaneous loading and about 0.47 under continuous loading. The strength to weight ratio in longitudinal loading was about 0.65 under instantaneous loading and about 0.36 under continuous loading. The strength to weight ratio in agglomeration loading was about 0.65 under instantaneous loading and about 0.36 under continuous loading.

  • PDF

Effects of Fatigue Induction on Ground Reaction Force Components, Postural Stability, and Vertical Jump Performance in Taekwondo Athletes

  • Hyun, Seung-Hyun;Kim, Young-Pyo;Ryew, Che-Cheong
    • 한국운동역학회지
    • /
    • 제26권2호
    • /
    • pp.143-151
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effect of fatigue induction on ground reaction force (GRF) components, postural stability, and vertical jump performance in Taekwondo athletes. Method: Ten Taekwondo athletes (5 men, 5 women; mean age, $22.30{\pm}2.62years$; mean height, $174.21{\pm}9.20cm$; mean body weight, $67.28{\pm}12.56kg$) participated in this study. Fatigue was induced by a short period of strenuous exercise performed on a motorized treadmill. The analyzed variables included vertical jump performance, static stability (mediolateral [ML], center of pressure [COP], anteroposterior [AP] COP, ${\Delta}COPx$, ${\Delta}COPy$, and COP area), postural stability index values (ML stability index [MLSI], AP stability index [APSI], vertical stability index [VSI], dynamic postural stability index [DPSI]), and GRF components (ML force, AP force, peak vertical force [PVF], and loading rate). To analyze the variables measured in this study, PASW version 22.0 was used to calculate the mean and standard deviation, while a paired t-test was used to evaluate the pre- versus post-fatigue results. Pearson's correlation coefficients among variables were also analyzed. The statistical significance level was set at ${\alpha}$ = .05. Results: Vertical jump performance decreased significantly after the induction of fatigue, while AP COP, ${\Delta}COPx$, COP area, APSI, VSI, and DPSI increased significantly. PVF and loading rate increased significantly after the induction of fatigue, while the postural stability variables (AP COP, ${\Delta}COPy$, COP area, APSI, VSI, DPSI) were similarly correlated with GRF components (PVF, loading rate) after fatigue was achieved (r = .600, $R^2$ = 37%). Conclusion: These results suggest that the induction of fatigue can decrease postural stability and exercise performance of Taekwondo athletes during training and competition sessions.

4H-SiC 표면에서 AFM의 산화 패턴 제작 (AFM fabrication of oxide patterns on 4H-SiC surface)

  • 조영득;방욱;김상철;김남균;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.64-64
    • /
    • 2009
  • Atomic force microscopy (AFM) fabrication of oxide patterns is an attractive technique for nanoscale patterns and related device structures, SiC exhibits good performance in high-power, high-frequency, and high-temperature conditions that is comparable to the performance of Si. The AFM fabrication of oxide patterns on SiC is important for electronic applications. However, there has not been much reported investigations on oxidation of SiC using AFM. We achieved the local oxidation of 4H-SiC using the high loading force of ~100 nN, although the oxidation of SiC is generally difficult mainly due to the physical hardness and chemical inactivity. All the experiments were performed using atomic force microscopy (S.I.S. GmbH, Germany) with a Pt/Ir-coated Si tip at ~40% humidity and room temperature. The spring constant and resonance frequency of the tip were around ~3 N/m and ~70 kHz. We fabricated oxide patterns on n-type 4H-SiC ($\sim10^{19}/cm^3$) and n-type Si ($\sim1.9\times10^{16}/cm^3$). In summary, we demonstrated that the oxide patterns can be obtained over the electric field of ${\sim}\times10^7 V/cm$ and the high loading force using the tip as a cathode. The electric field transports the oxyanions (OH-) to the positively biased surface.

  • PDF

Sinking and fit of abutment of locking taper implant system

  • Moon, Seung-Jin;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권2호
    • /
    • pp.97-101
    • /
    • 2009
  • STATEMENT OF PROBLEM. Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE. In this study, Bicon$^{(R)}$ Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS. 10 Bicon$^{(R)}$ implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS. It was evident, that the amount of abutment sinking in Bicon$^{(R)}$ Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at $0.45{\pm}0.09\;mm$. CONCLUSION. Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.

재하시험을 통한 사장교의 케이블 장력 모니터링 시스템의 적용성 평가 (Evaluation of Applicability of Cable Force Monitoring System of Cable-stayed Bridge by Field Loading Test)

  • 김정훈;송재호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권1호통권53호
    • /
    • pp.205-213
    • /
    • 2009
  • 본 연구에서는 사장교의 케이블 장력을 장기적인 관점에서 보다 효과적으로 분석하고 모니터링할 수 있는 케이블 장력 모니터링 시스템을 개발하는 연구를 수행하였다. 제안된 모니터링 시스템에는 실시간 동적 데이터에서 일정 대상시간 동안의 가속도 데이터를 선정하고, 이를 고속 푸리에 변환 알고리즘에 적용하여 주파수 분석한 결과를 평균하여 일반화시키는 신호해석이론이 적용되었다. 제안된 케이블 장력의 모니터링 시스템의 적용성을 평가하기 위하여 실제 공용중인 사장교에 대한 현장재하시험을 실시하였다. 현장계측을 통한 수동으로 계산된 장력과 모니터링 시스템의 강제저장 기능을 통해 저장된 데이터를 수계산하여 반자동으로 계산된 장력을 비교한 결과, 장력차이가 1% 이내로 발생하였고, 제안된 모니터링 시스템에서 자동으로 계산된 장력을 비교한 결과에서는 약 5% 범위의 무시할만한 차이로 나타나 본 연구에서 제안된 사장교 케이블 장력 모니터링 시스템의 신뢰도를 검증하였다.

궤도-교량의 상호작용에 대한 하중이력의 영향 (The Loading History Effect on the Track-bridge Interaction)

  • 윤경민;한상윤;황만호;김해곤;임남형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3156-3159
    • /
    • 2011
  • In case of the continuous welded rail(CWR) track is supported by the railway bridge, the additional axial force is occurred in the CWR due to the track-bridge interaction. In the various design codes such as Korean code, European code, UIC code, etc, three important loads(temperature variation in the bridge-deck, braking/acceleration and the bending of the bridge-deck resulted from the passing train) are treated as the independent loading case. In other words, the additional axial force can be obtained by summing up the three different values calculated by the three independent analysis. However, this analysing method may have an error because the behavior of the longitudinal resistance between the rail and the bridge-deck is under the highly nonlinear. Therefore, in order to exactly analyse the track-bridge interaction, nonlinear loading history and the change of the longitudinal resistance owing to the loading history must be considered in the analysis process. In this study, the loading history effect on the track-bridge interaction is investigated considering the resonable combination of three loads and the longitudinal resistance change.

  • PDF