• Title/Summary/Keyword: Load step

Search Result 1,013, Processing Time 0.032 seconds

A Calculation of Unbalanced Current on Neutral Line in Two Step Type Pole (2단장주 중성선 불평형 전류 계산)

  • Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.484-485
    • /
    • 2006
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current may occurs in three-phase four-wire distribution system due to unbalanced load. This paper presents neutral current both one step type pole and two step type pole in distribution system.

  • PDF

Effects of Distributed Load on the Dynamic Response of the Reinforced Concrete Slabs (분포하중이 철근 콘크리트 슬래브의 동적 거동에 미치는 영향)

  • Oh, Kyung-Yoon;Cho, Jin-Goo;Choi, Soo-Myung;Hong, Chong-Hyun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.19-26
    • /
    • 2008
  • This study has been carried out to investigate the dynamic characteristics of RC slabs. For this purpose, the 20-node solid element has been used to discretize the RC slabs into two parts of concrete and rebar. The material non-linearity considering elasto-visco plastic model and the smeared crack model have been adopted in the finite element formulation. The applied load can handle step load, load intensity of harmonic load, area of distributed load and frequency. The frequency of harmonic load has an significant effect on dynamic behaviour in terms of displacement. As the frequency is increased, the effect of load amplitude is more serious. Especially, if the frequency of harmonic load exceeds 30 Hz, it is noted that the displacement by harmonic load is greater than that by step load. In case of harmonic load, the damping effect shows no certain tendency with respect to frequency of load. In details, the damping is effective when the frequency of harmonic load is 2 Hz, but there is no consistent tendency according to damping ratio. The dynamic response when the frequency of harmonic load is 3 Hz shows same result for undamped case as well as for damped case with 5% damping ratio. It is also noted that we can get the largest deflection for damped case with 1% damping ratio. However, there is not any damping effect when the frequency of harmonic load is greater than 4 Hz.

Initial Imperfection Sencitivity in Stiffened Plates (보강판의 초기결함 민감성 연구)

  • 김천욱;원종진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.3
    • /
    • pp.264-273
    • /
    • 1984
  • 초기경향이 있는 보강평판의 비선형 운동 방정식을 Galerkin method에 의하여 유도하였다. Runge Kutta method를 사용하여 step-load를 받고 있는 보강평판의 동적 좌굴문제의 수치해를 구하였다. 정적 좌굴실험에 의하여 좌굴하중을 결정함에 있어 동적 해석법을 응용할 수 있음을 입증하였으며, step-load를 받는 보강평판의 동적 좌굴해석으로 정적좌굴의 초기결함 민감성을 해 석하였다. 보강평판의 초기결함민강성은 평판보다 훨씬 낮으며 보강재의 편심비가 높을수록 민감 성은 둔화된다.

Electronic Step-down Transformer (전자식 강압형 트랜스포머)

  • Seo, J.H.;Kim, M.G.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.74-77
    • /
    • 2005
  • An electronic step-down transformer is proposed. Conventional iron cored transformer is heavy and bulky and it has substantial amount of no load loss. On the other hand, electronic transformer can provide negligible no load loss, small size, and light weight. It consists of rectifier and PWM inverter. The output voltage is controlled by duty ratio. To confirm the validity of the proposed transform, simulation and experimental results are presented.

  • PDF

A Comparative Analysis of Dynamic Instability Characteristic of Geiger-Typed Cable Dome Structures by Load Condition (Geiger형 케이블 돔 구조물의 외력에 따른 동적 불안정 특성 비교분석)

  • Kim, Seung-Deog;Sin, In-A
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.1
    • /
    • pp.85-91
    • /
    • 2014
  • The purpose of this paper is to study comparative of dynamic instability characteristic of Geiger-typed cable dome structures by load condition, which is well-known among the cable dome structures that are the lightweight hybrid structure using compression and tension element continuously. Dynamic buckling process in the phase plane is very important thing for understanding why unstable phenomena are sensitively originated in nonlinear dynamic by various initial conditions. But there is no paper for the dynamic instability of hybrid cable dome by Sinusoidal Excitations, many papers which deal with the dynamic instability for shell-structures under the step load have been published. As a result of Geiger-typed cable dome, which shows chaotic behavior in dynamic nonlinear analysis with initial imperfection.

A Study on the Flying Characteristics of Zero-Load Sliders (제로-로드 슬라이더의 부상특성에 관한 연구)

  • 윤상준;강태식;최동훈
    • Tribology and Lubricants
    • /
    • v.11 no.2
    • /
    • pp.15-23
    • /
    • 1995
  • A zero-load slider is composed of two outside rails which produce a lift force pushing up the slider from the disk surface and a wide reverse step region which produces a suction force attracting the slider to the disk surface. In this paper, the flying characteristics of zero-load sliders are obtained by using an optimization technique. In the pressure calculation module, the FIFD scheme is used to solve the modified Reynolds equation. The BFGS method and a line search algorithm is employed to predict the static flying attitude. To investigate the effect of the geometric- parameters of zero-load sliders on the flying characteristics, recess depth, front step width, rail width, and taper height are varied and the corresponding flying attitudes are obtained. Simulation results demonstrate that recess depth and rail width have significant influences on the flying characteristics.

Resonance characteristics and electrical properties of PZT-piezoelectric transformer (PZT계 압전변압기의 공진특성과 전기적 성질)

  • 박순태;정수태;이종헌
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.27-34
    • /
    • 1995
  • The analysis of nonlinear equivalent circuit and the resonance characteristics of input current and output voltage were simulated, and their electrical properties are discussed in the transverse-type piezoelectric ceramic transformer. The nonlinear resonance characteristics of input current and output voltage showed by the thermal effect due to a higher driving current, the nonlinearity increased greatly as driving current increased. When load resistor was 100[M.ohm.], the nonlinear coefficient was -1.3. The nonlinear resonance curve of input current and output voltage for a variation of input voltage and load resistor agreed with the discussed theory. The output voltage increased nearly proportioned to input voltage when load resistors were below 50[M.ohm.], the voltage step-up ratio decreased when a load resistor was 100[M.ohm.] and their maximum value was 950.

  • PDF

The Relationship between Critical Load and Frequency of Sinusolidally Non-symmetrically Tapered Member (정현상 비대칭으로 Taper진 부재의 임계하중과 고유진동수와의 관계)

  • Lee, Hyuck;Hong, Jong-Kook;Lee, Soo-Gon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.59-66
    • /
    • 2000
  • It is generally known that the lateral frequency( ω) of the vibration of a prismatic beam-column decreases according to the rele (equation omitted) (ω/sub 0/=natural frequency). In the cases of tapered members, the determination of P/ sub/ cr/(elastic critical load) and ω/ sub 0/ are not easy. Furthermore, the relationship between the compressive load and frequency can not be determined by the conventional analytical method. The axial force-frequency relationship of sinusolidally non-symmetrically tapered members with different shapes were investigated using the finite element method. To obtain the two eigenvalues, the axial thrust was increased step by step and the corresponding frequency was calculated. The result indicated that the axial thrust of the elastic critical load ratio and the square of the frequency ratio can be approximately represented in any case by a straight line. Finally, the linear relationship is also applicable to the sinusolidally non-symmetrically tapered member.

  • PDF

The Self-Fault Restoration Methodology based on the Recloser in the Distribution Systems (배전계통 리클로우저 기반의 자율적 고장복구 방법론)

  • Ko, Yun-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1681-1688
    • /
    • 2009
  • This paper proposes a new fault restoration method which adopts the recloser as top agent to release the problems of the data concentration and fault processing delay of the existing DAS(distribution Automation System) under the ubiquitous distribution system. In proposed method, top agent collects the data based on the multi-casting communication with the tie switches of the interconnection point, and then selects a closed switch(tie switch) to transfer the sound outage load to other feeders based on the heuristic search strategy step by step until the load transfer work is finished. Here, a new heuristic rule is developed which can guarantee the relational load balancing and line loss from the collected voltage data. Finally, the several faults are simulated for typical multi-section and multi-interconnection distribution system to prove the effectiveness of the proposed strategy, in particular, for each simulation cases, the load balancing index and line loss index of the obtained solution from the proposed method is compared with those of all of feasible solutions.

Soft-Switching Auxiliary Current Control for Improving Load Transient Response of Buck Converter

  • Kim, Doogwook;Shin, Joonho;Shin, Jong-Won
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.160-162
    • /
    • 2020
  • A control technique for the auxiliary buck/boost converter is proposed herein to improve the load transient response of the buck converter. The proposed technique improves the system efficiency by enabling the soft switching operation of the auxiliary converter. The design guidelines for achieving capacitor charge balance for the output capacitor during the transient are also presented herein. The experimental results revealed that the output voltage undershoot and settling time during the load step-up transient were 40 mV and 14 ㎲, respectively, and the output voltage overshoot and settling time during the load step-down transient were 35 mV and 21 ㎲, respectively. The performance and effectiveness of the proposed technique were experimentally verified using a prototype buck converter with a 15-V input, 3.3-V output, and 200-kHz switching frequency.

  • PDF