• 제목/요약/키워드: Load cells

검색결과 452건 처리시간 0.027초

The Silicon Type Load Cell with SUS630 Diaphragm (SUS630 다이아프램을 이용한 반도체식 로드셀)

  • Moon, Young-Soon;Lee, Seon-Gil;Ryu, Sang-Hyuk;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • 제20권3호
    • /
    • pp.213-218
    • /
    • 2011
  • The load cell is a force sensor and a transducer that is used to convert a physical force into a electrical signal for weighing equipment. Most conventional load cells are widely used a metal foil strain gauge for sensing element when force being applied spring element in order to converts the deformation to electrical signals. The sensitivity of a load cell is limited by its low gauge factor, hysteresis and creep. But silicon-based sensors perform with higher reliability. This paper presents the basic design and development of the silicon type load cell with an SUS630 diaphragm. The load cell consists of two parts the silicon strain gauge and the SUS630 structure with diaphragm. Structure analysis of load cell was researched by theory to optimize the load cell diaphragm design and to determine the position of peizoresistors on a silicon strain gauge. The piezo-resistors are integrated in the four points of silicon strain gauge processed by ion implantation. The thickness of the silicon strain gauge was polished by CMP under 100 ${\mu}M$. The 10 mm diameter SUS630 diaphragm was designed for loads up to 10 kg with 300 ${\mu}M$ of diaphragm thickness. The load cell was successfully tested, the variation of ${\Delta}$R(%) of four points on the silicon strain gauge is good linearity properties and sensitivity.

Analysis and comparison of initial performance degradation for single crystalline silicon solar cell under open and short circuit (단결정 태양전지의 단락 및 개방 시 노광에 의한 초기 출력저하 비교 분석)

  • Jung, Tae-Hee;Kim, Tae-Bum;Shin, Jun-Oh;Yoon, Na-Ri;Woo, Sung-Cheol;Kang, Gi-Hwan;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • 제30권6호
    • /
    • pp.16-21
    • /
    • 2010
  • It is well-known that Boron-doped Cz Si solar cells suffer light-induced degradation due to boron-oxygen defect which is responsible of a reduction in lifetime and hence efficiency. In this paper, we assume that PV solar cell has been connected with variable load to account the real operating condition and it shows different light-induced degradation of Si solar cell. To evaluate the effect of light-induced degradation for solar cell with various load, Single crystalline solar cells are connected with open and short circuits during light exposure. Isc-Voc curve evaluate light induced degradation of solar cells and the reason is explained as a change for serial resistance. From the results, Electrical characteristics of solar cells show better performance under short circuit conditions, after light exposure.

A Generalization of High Frequency Converter with Lossless Snubber Cell (무손실 스너버 셀을 갖는 고주파 컨버터의 일반화)

  • Joung Gyu-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.478-484
    • /
    • 2004
  • In this paper, two lossless snubber cells are proposed to generalize high frequency converter with losslless snubber. The selecting of snubber cells, which generalize high frequency converters, are depended on converter topologies. The cells have a saturable inductor, LC resonant tank and two diodes. In the cells, the saturable inductors extremely reduce resonant energy in the LC resonant tank. By minimizing resonant energy, the converter, which applies snubber cells, can operate at high frequency. These cells are applied for Buck, Boost, Buck-Boost, Cuk, ZETA, and SEPIC to generalize converter which have lossless snubber. The boost type converter has been implemented, with 400 kHz switching frequency for 125 W load to verify the converter characteristics.

Interference Cancellation and Load Balancing in Heterogeneous Cellular Networks (이기종 셀룰러 네트워크에서 간섭 제거와 로드 밸런싱)

  • Lee, Kyoung-Jae;Jo, Han-Shin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제51권10호
    • /
    • pp.45-49
    • /
    • 2014
  • In this paper, the performance of the interference cancellation using multiple receive antennas is evaluated for heterogeneous cellular systems when user association and load balancing problems are optimized for cell edge users. The simulation results show that the interference cancellation method remarkably improves the rate performance of load-balanced cells.

Improvement of Power Generation of Microbial Fuel Cells using Maximum Power Point Tracking (MPPT) and Automatic Load Control Algorithm (최대전력점추적방법과 외부저항 제어 알고리즘을 이용한 미생물연료 전지의 전력생산 최대화)

  • Song, Young Eun;Kim, Jung Rae
    • KSBB Journal
    • /
    • 제29권4호
    • /
    • pp.225-231
    • /
    • 2014
  • A microbial fuel cell (MFC) and bioelectrochemical systems are novel bioprocesses which employ exoelectrogenic biofilm on electrode as a biocatalyst for electricity generation and various useful chemical production. Previous reports show that electrogenic biofilms of MFCs are time varying systems and dynamically interactive with the electrically conductive media (carbon paper as terminal electron acceptor). It has been reported that maximum power point tracking (MPPT) method can automatically control load by algorithm so that increase power generation and columbic efficiency. In this study, we developed logic based control strategy for external load resistance by using $LabVIEW^{TM}$ which increases the power production with using flat-plate MFCs and MPPT circuit board. The flat-plate MFCs inoculated with anaerobic digester sludge were stabilized with fixed external resistance from $1000{\Omega}$ to $100{\Omega}$. Automatic load control with MPPT started load from $52{\Omega}$ during 120 hours of operation. MPPT control strategy increased approximately 2.7 times of power production and power density (1.95 mW and $13.02mW/m^3$) compared to the initial values before application of MPPT (0.72 mW and $4.79mW/m^3$).

Effect Reinforced Ground using Geocell (지오셀을 적용한 지반의 보강효과에 관한연구)

  • Shin, Eun-Chul;Kim, Sung-Hwan;Oh, Young-In
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.782-791
    • /
    • 2009
  • This study was carried out the laboratory tests and field plate load test in order to evaluate the reinforcement effect of geocell for road construction. The geocell-reinforced subgrade shows the increment of cohesion and friction angle with comprison of non-reinforced subgrade. In addition, the field plate load test was performed on the geocell-reinforced subgrade to estimate the bearing capacity of soil. The direct shear test was conducted with utilizing a large-scale shear box to evaluate the internal soil friction angle with geocell reinforcement. The number of cells in the geocell system is varied to investigate the effect of soil reinforcement. The theoretical bearing capacity of subgrade soil with and without geocell reinforcement was estimated by using the soil internal friction angle. The field plate load tests were also conducted to estimate the bearing capacity with geocell reinforcement. It is found out that the bearing capacity of geocell-reinforced subgrade gives 2 times higher value than that of unreinforced subgrade soil. In the future, the reinforcement effect of the geocell rigidity and load-balancing effect of the geocells should be evaluated.

  • PDF

Adaptive Load Balancing Algorithm and Its Performance Analysis Based on System-Level Simulations in Indoor Mobile Communication System (옥내용 모바일 통신 시스템을 위한 적응적 Load-Balancing 알고리즘 제안 및 시스템 레벨 시뮬레이션 기반 성능 분석)

  • Lee, Woongsup;Lee, Howon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제17권11호
    • /
    • pp.2563-2568
    • /
    • 2013
  • Recently, various solutions to support explosively growing mobile data traffic have attracted intensive attentions. However, the range of spectrum which can be exploited for mobile communications is very limited. Small cell networks are actively investigated because they can efficiently offload mobile data traffic from macro cells without using additional spectrum. In this paper, we developed a system-level simulator considering small cell networks in the indoor environments. We compare the performance of outage probability when a load-balancing algorithm is utilized or not. We can reduce the outage probability of congested BS with the load-balancing algorithm. In addition, overall outage probability of whole wireless systems can be reduced by using the proposed load-balancing algorithm.

Fabrication and Characteristics of 30 MN Strain Gage Type Force Sensor (30 MN 스트레인 게이지 방식 힘 센서의 제작 및 특성)

  • Kang, D.I.;Song, H.K.;Lee, J.T.
    • Journal of Sensor Science and Technology
    • /
    • 제3권2호
    • /
    • pp.24-32
    • /
    • 1994
  • A force sensor of 30 MN capacity using build-up technique in which three load cells of 10 MN capacity are arranged in parallel was fabricated. A column spring element was adopted as a shape of a strain gage type load cell. Temperature compensation circuits were used to reduce the error of a load cell. It was estimated that the total error of the fabricated force sensor is less than 0.1 %. The force sensor may be used to calibrate or test material testing machines above 4.5 MN capacity in industries.

  • PDF

The of Rack with Modularized Cell considering Heterogeneous Unit Load Size in AS/RS (자동창고 Effectiveness 시스템에서 크기가 다른 저장단위를 고려한 모듈화 셀을 갖는 랙의 효과)

  • 이문환;이영해
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 대한산업공학회/한국경영과학회 2000년도 춘계공동학술대회 논문집
    • /
    • pp.1-4
    • /
    • 2000
  • In general, under the concept of unit load, Automated Storage/Retrieval Systems (AS/RS) have the rack of equal sized cells. However, they are inadequate and inefficient meeting the various sizes of customers' demands in today's business environment. Higher utilization and flexibility of warehouse storage can be achieved by using AS/RS with tile rack of modularized cell. In this paper, the model of AS/RS with the rack of modularized cell is proposed, and the effectiveness of proposed model is presented by way of numerical examples. The model developed in this research, as one type of AS/RS that is more flexible to the size and has higher space utilization than those of existing rack structure, could every useful for the storage of heterogeneous unit load sizes.

  • PDF

M/G/1 Queueing Model for the Performance Estimation of AS/RS (자동창고시스템의 성능평가를 위한 M/G/1 대기모형)

  • Lee, Mun-Hwan;Lim, Si-Yeong;Heo, Seon;Lee, Yeong-Hae
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 대한산업공학회/한국경영과학회 2000년도 춘계공동학술대회 논문집
    • /
    • pp.253-256
    • /
    • 2000
  • In general, Automated Storage/Retrieval Systems (AS/RS ) have racks of equal sized cells to utilize the concept of unit-load. Most of the techniques for the performance estimation of a unit-load AS/RS are a static model or computer simulation. Especially, their models were developed under assumption that the Storage/Retrieval (S/R) machine performs only single command (SC) or dual command (DC). In reality, defending on the operating policy and the status of the system at a particular time, the S/B machine performs a SC or a DC, or becomes .: idle. In order to resolve these weak points, we propose a stochastic model for the performance estimation of unit-load AS/RS by using a single-server queueing model. Expected numbers of waiting storage and retrieval commands are found

  • PDF