• Title/Summary/Keyword: Load Cell

Search Result 1,194, Processing Time 0.028 seconds

Development of Wireless Respiratory Air Flow and Urinary Flow Measurement System for Home Healthcare (가정용 무선 호흡기류 및 요속신호 계측 시스템 개발)

  • Cha, Eun-Jong;Lee, In-Kwang;Lee, You-Mi;Han, Soon-Wha;Han, Jeong-Su;Suh, Jae-Won;Park, Chan-Sik;Kim, Kyung-Ah
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1350-1357
    • /
    • 2012
  • Medical system for personal health management recently changes its paradigm from hospital service to self home care based on ubiquitous technology for healthcare anywhere at any time. The present study developed a wireless bio-signal measurement system for patients to self manage pulmonary disease and benign prostate hyperplasia(BPH), both of which are chronic diseases with increasing frequency in modern society. Velocity-type respiratory air flow transducer adapted to develop respiratory module for pulmonary disease management was simplified in structure to measure uni-directional flow since most important diagnostic parameters are evaluated on the expiratory flow signal only. Standard weight measurement technique was introduced to obtain urinary flow signal for BPH management. Three load cell signals were acquired for averaging to minimize noise, followed by accuracy evaluation. Transmission and receiver modules were also developed with user program for wireless communication. Averaged relative errors were 2.05 and 1.02% for respiratory volume and maximal flow rate, respectively, and the relative error was 2.17% for urinary volume, demonstrating that both modules enabled very accurate measurements. Wireless communication distance was verified within 15m, long enough for home care application. The present system allows the user to select a necessary measurement module on a particular health demand and to immediately provide the self-test results, thus better quality health care would be possible.

An Experimental Study on Aerodynamic Characteristics of a Flapping Wing (플래핑 날개의 공력특성에 관한 실험적 연구)

  • Song, Woo-Gil;Chang, Jo-Won;Jeon, Chang-Su
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.17 no.4
    • /
    • pp.8-16
    • /
    • 2009
  • An experimental study was carried out to investigate aerodynamic characteristics on reduced frequency of flapping wings. The half span of the wing is 28cm, and the mean chord length of wing is 10cm. In flight, the Reynolds Number range of birds is about $10^4$, and the reduced frequency during a level flight is 0.25. The experimental variables of present study were set to have similar conditions with the bird flight's one. The freestream velocities in a wind tunnel were 2.50, 3.75 and $5.00^m/s$, and the corresponding Reynolds numbers were $1.7{\times}10^4$, $2.5{\times}10^4$ and $3.3{\times}10^4$, respectively. The wing beat frequencies of an experimental model were 2, 3 and 4Hz, and the corresponding reduced frequency was decided between 0.1 and 0.5. Aerodynamic forces of an experimental flapping model were measured by using 2 axis load-cell. Inertial forces measured in a vacuum chamber were removed from measuring forces in the wind tunnel in order to acquire pure aerodynamic forces. Hall sensors and laser trigger were used to make sure the exact position of wings during the flapping motion. Results show that the ratio of downstroke in a wing beat cycle is increased as a wing beat frequency increases. The instantaneous lift coefficient is the maximum value at the end of downstroke of flapping wing model. It is found that a critical reduced frequency with large lift coefficient is existed near k=0.25.

  • PDF

The Performance Evaluation for PHY-LINK Data Transfer using SPI-4.2 (SPI-4.2 프로토콜을 사용한 PHY-LINK 계층간의 데이터 전송 성능평가)

  • 박노식;손승일;최익성;이범철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.577-585
    • /
    • 2004
  • System Packet Interface Level 4 Phase(SPI-4.2) is an interface for packet and cell transfer between a physical layer(PHY) device and a link layer device, for aggregate bandwidths of OC-192 ATM and Packet Over Sonet/SDH(POS), as well as 10Gbps Ethernet applications. In this paper, we performs the research for SPI-4.2. Also we analyze the performance of SPI-4.2 interface module after modeling using C programming language. This paper shows that SPI-4.2 interface module with 512-word FIFO depth is able to be adapted for the offered loads to 97% in random uniform traffic and 94% in bursty traffic with bursty length 32. SPI-4.2 interface module can experience an performance degradation due to heavy overhead when it massively receives small size packets less than 14-byte. SPI-4.2 interface module is suited for line cards in gigabit/terabit routers, and optical cross-connect switches, and SONET/SDH-based transmission systems.

Implementation and Estimation of the LUTS Diagnosis System for Home Health Care (홈 헬스케어에 적용 가능한 하부요로계 폐색 모니터링 시스템 구현 및 평가)

  • Jeong Do-Un;Chung Wan-Young;Jeon Gye-Rork
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.697-700
    • /
    • 2006
  • A sensor and measuring system were implemented to measure two signals that uroflow and urophonography during urination for diagnose the lower urinary tract symptom. The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluate the implemented system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter the most influence of effect according to occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253\sim282Hz$ of the urophonography signal.

  • PDF

Service Self-Organization Method in LTE-Advanced Heterogeneous Networks (LTE-Advanced 융합 망에서 서비스 자기-조직화 방법)

  • Lee, Gi-Sung;Lee, Jong-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6260-6268
    • /
    • 2015
  • In LTE-Advanced that different networks coexist, it is considered that it is actually difficult to provide service continuity with a procedural and static control method applied to the existing voice service. This paper suggests Service Self-Organization to support the service continuity effectively based on SON. It means a method in which a subscriber's terminal collects information about its current condition and base station around, and a base station, through the data collected by monitoring inner or adjacent base station, shares related data and converges, controlling service continuity on its own. In other words, as context information of mobile terminal and base station changes, set-up of related functions such as ISHO, cell selection, source allocation, load control, and QoS mapping is adapted; each function fits into the change, exchanges the process of reorganization, and interacts; these actions go toward to satisfy service continuity. Simulation results show that it provides better performances than the conventional one with the measure of resource utilization rate and outage probability.

Technology of Non-destructive Stress Measurement in Spot Welded Joint using ESPI Method (ESPI법에 의한 스폿 용접부의 비파괴적 응력측정 기술)

  • 김덕중;국정한;오세용;김봉중;유원일;김영호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2000
  • In spot welded joint. Electronic Speckle Pattern Interferometry(ESPI) method using the Model 95 Ar laser a video system and an image processor was applied to measure the stress Unlike traditional strain gauges or Moire method, ESPI method has no special surface preparation or attachments and can be measured in-plane displacement with non-contact and real time. In this experiment, specimens are loaded in parallel with a load cell. The specimens are made of the cold rolled steel sheet with 1mm thickness, are attached strain. gauges. This study Provides an example of how ESPI has been used to measure stress and strain inspecimen. The results measured by ESPI are compared with the data which was measured by strain gauge method under tensile testing.

  • PDF

Isolation of Sulfur Oxidizing Bacteria from Different Ecological Niches (다양한 생태계에서 분리한 황 산화 세균)

  • Anandham, Rangasamy;Sridar, Ragupathy;Nalayini, Periyakaruppan;Madhaiyan, Munusamy;Gandhi, Pandiyan Indira;Choi, Kwan-Ho;Sa, Tong-Min
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.4
    • /
    • pp.180-187
    • /
    • 2005
  • Nine chemolithoautotrophic and 12 chemolithoheterotrophic sulfur oxidizing bacteria were isolated using enrichment technique in modified Starkey's medium. All isolates reduced pH of the growth medium through oxidation of elementai sulfur to sulfuric acid. Isolates utilized the thiosulfate as energy source except LCH. None of the isolates grew anaerobically and utilization of glucose was found only in chemolithoheterotrophic isolates SGA6 and JIG. In vitro sulfate production from elemental sulfur was found maximum for chemoiithoautotroph LCH ($43.2mg\;100\;mL^{-1}$) and least for chemolithoheterotroph JIG ($10.04mg\;100\;mL^{-1}$). The above tests suggested that all isolates belong to the member of Thiobacillus. For field inoculation of Thiobacillus, clay based pellet formulation was developed with the cell load of $2.5{\times}10^7cfu\;g^{-1}$ of pellet. It is easy to handle by the farmers and more likely to lead to successful farming.

Performance Evaluation of a Large-scale MR Damper for Controlling Seismic Responses Using a Real-time Hybrid Test Method (실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 제진 성능평가)

  • Park, Eun-Churn;Lee, Sung-Kyung;Youn, Kyung-Jo;Chung, Hee-San;Lee, Heon-Jae;Choi, Kang-Min;Moon, Suk-Jun;Jung, Hyung-Jo;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.131-138
    • /
    • 2008
  • This paper presents real-time hybrid test method of large-scale MR damper applied to a building structure under seismic excitation. The real-time hybrid test using an actuator for the control performance evaluation of a MR damper controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a large-scale MR damper adopted as an experimental part was installed to reduce its response. At first, the force that is acting between a MR damper and building structure is measured from the load cell attached on the actuator system and is fed-back to the computer to control the motion of the actuator. Then, the actuator is so driven that the error between the interface displacement computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the actuator. The control efficiency of the MR damper used in this paper is experimentally confirmed by implementing this process of experiment on real-time.

Earthquake Response Control of a Building with a Tuned Liquid Damper Using Hybrid Experiment Method (하이브리드 실험법을 이용한 TLD가 설치된 건물의 지진응답 제어)

  • Lee, Sung-Kyung;Lee, Sang-Hyun;Min, Kyung-Won;Park, Eun-Churn;Woo, Sung-Sik;Chung, Lan;Youn, Kyung-Jo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.527-534
    • /
    • 2006
  • A real-time hybrid method, in which the experimental implementation and the numerical computation of a structure are simultaneously carried out in real-time and combined on-line, has been used as a dynamic testing technique of structure to investigate its dynamic behaviors. In this paper, an experimental hybrid method, which implements the earthquake response control of a building structure with a TLD by using only a TLD as an experimental part, is proposed and is experimentally verified through a shaking table test. In the proposed methodology, the whole building structure with a TLD is divided into the upper TLD and the lower structural parts as experimental and numerical substructures, respectively. At the moment, the control force acting between their interface is measured from the experimental TLD with shear-type load-cell which is mounted on shaking table. Shaking table vibrates the upper experimental TLD with the response calculated from the numerical substructure, which is subjected to the excitations of the measured interface control force at its top story and an earthquake input at its base. The experimental results show that the conventional method, in which both a TLD and a building model are physically manufactured and are tested, can be replaced by the proposed methodology with a simple experimental installation and a good accuracy for evaluating the control performance of a TLD.

  • PDF

Wave Drag Reduction due to Repetitive Laser Pulses (반복 레이저 펄스를 이용한 초음속 비행체의 항력저감)

  • Kim, Jae-Hyung;Sasoh, Akihiro;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.381-384
    • /
    • 2011
  • Wave drag reduction due to the repetitive laser induced energy deposition over a flat-nosed cylinder is experimentally conducted in this study. Irradiated laser pulses are focused by a convex lens installed in side of the in-draft wind tunnel of Mach 1.94. The maximum frequency of the energy deposition is limited up to 80. Time-averaged drag force is measured using a low friction piston which was backed by a load cell in a cavity as a controlled pressure. Stagnation pressure history, which is measured at the nose of the model, is synchronized with corresponding sequential schlieren images. With cylinder model, amount of drag reduction is linearly increased with input laser power. The power gain only depends upon the pulse energy. A drag reduction about 21% which corresponds to power gain of energy deposition of approximately 10 was obtained.

  • PDF