• Title/Summary/Keyword: Liver, MR imaging

Search Result 69, Processing Time 0.035 seconds

Chemical Saturation Breath-hold Fast MR Imaging for characterization of Regional Fatty Changes in Liver (화학적 포화 호흡정지 급속 자기공명영상에서 국소적 간지방병변의 특성화)

  • 김동국;유정식;김태훈;오세정;김지형
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.135-141
    • /
    • 1997
  • Purpose: To assess the usefulness of breath-hold fast MR imaging of liver with fat suppression (FS) by application of chemical saturation technique in the diagnosis of regional fatty changes suspected in sonography. Materials and Methods: Thirteen patients who had focal lesions with diffuse, homogeneous signal changes after FS through chemical saturation technique without additional changes of imaging parameter during MR imaging of liver were selected. T1-weighted fast low-angle shot and T2-weighted turbo spin-echo sequences were obtained with or without FS during each single breath-holding session. Subjective changes of signal intensity between the pre-FS and the FS images were compared with the sonographic findings in each lesion. Results: Seven lesions of decreased signal intensity after FS on T1 or T2-weighted images, including three lesions only at FS T1 images, were regarded as focal fat infiltration. All seven lesions had compatible sonographic findings as homogenously echogenic areas. Another six lesions of subjectively increased signal intensity including two lesions only at FS T2 images were regarded as focal fat sparing. All six lesions had sonographic findings as homogenous echo poor areas suggesting focal fat sparing. In cases regarded as fat infiltration, score changes were more prominent at FS T1 images than FS T2 images(p=0.0002). In cases regarded as fat sparing, score changes were more prominent at FS T2 images than FS T1 images(p=0.042). Conclusion: Breath-hold fast T1 and T2-weighted MR imaging with and without chemical saturation pre-pulse may be sufficient for characterization of regional fatty changes in the differential diagnosis of focal hepatic lesion found at sonography.

  • PDF

An Automated Way to Detect Tumor in Liver

  • Meenu Sharma. Rafat Parveen
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.10
    • /
    • pp.209-213
    • /
    • 2023
  • In recent years, the image processing mechanisms are used widely in several medical areas for improving earlier detection and treatment stages, in which the time factor is very important to discover the disease in the patient as possible as fast, especially in various cancer tumors such as the liver cancer. Liver cancer has been attracting the attention of medical and sciatic communities in the latest years because of its high prevalence allied with the difficult treatment. Statistics indicate that liver cancer, throughout world, is the one that attacks the greatest number of people. Over the time, study of MR images related to cancer detection in the liver or abdominal area has been difficult. Early detection of liver cancer is very important for successful treatment. There are few methods available to detect cancerous cells. In this paper, an automatic approach that integrates the intensity-based segmentation and k-means clustering approach for detection of cancer region in MRI scan images of liver.

Solitary Necrotic Nodule of the Liver Mimicking Metastasis in Patient with Early Gastric Cancer : 3T MRI and PET/CT Findings (조기 위암 환자에서 전이암과 감별이 필요했던 간내 단발성 궤사성 결절: 3T MRI 및 PET/CT 소견)

  • Cho, Woo-Sun;Kim, Gi-Hyeon;Lee, Hwa-Yeon;Lee, Jong-Beum;Kwon, Gui-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.213-217
    • /
    • 2009
  • Solitary necrotic nodule (SNN) of the liver is a very uncommon benign lesion, and it is detected incidentally as a rule. It is important to differentiate SNN radiologically from various single hepatic nodules because SNN mimics hepatic metastasis, especially in staging work up of known primary malignancy. The reported imaging findings of SNN are well-defined nodule without enhancement or with subtle peripheral enhancement. There has been no report about the target-like SNN of the liver and about the imaging finding of 3T magnetic resonance imaging and positron emission tomography. We report a case of targetlike SNN of the liver, mimicking hepatic metastasis, with findings of various imaging modalities and try to find a cause of this nodule according to the pathologic and literature review.

  • PDF

Changes in SNR and ADC According to the Increase in b Value in Liver Diffusion-Weighted Images

  • Cho, Jae-Hwan;Kim, Ham-Gyum
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.219-224
    • /
    • 2012
  • In the present study, changes in signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) of the diffusion-weighted images in the normal livers were investigated using changes in b values in 1.5 T MR (magnetic resonance) instruments. Respective diffusion-weighted images and ADC map images were obtained from 20 healthy individuals by increasing b values from 50 to 400 and 800 $s/mm^2$ using 1.5T MR scanner between January 2011 and November 2011. At each ADC map image obtained at each b value, ADCs in the right hepatic lobe, spleen and kidney were measured. As a result, ADCs of the right hepatic lobe, spleen and kidney have gradually decreased in the diffusion-weighted images in accordance with the reduced b value. This outcome may be used as preliminary data for applications to various abdominal diseases.

The Synthesis and MR Properties of New Macromolecular MR Contrast Agent (새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Purpose : To evaluate the NMR relaxation properties and imaging characteristics of tissue-specificity for a newly developed macromolecular MR agent. Materials and methods : Phthalocyanine (PC) was chelated with paramagnetic ion, Mn.2.01g (5.2 mmol) of Phthalocyanine was mixed with 0.37g (1.4 mmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography (CHC13/CH3OH 98/2 v/v, Rf, 0.76) to obtain 1.04g (46%) of MnPC (molecular weight= 2000d). The $T1}T2$ relaxivity of MnPC was measured in 1.5T(64 MHz) MR using 0.1 mM MnPC. The MR image characteristics of MnPC was evaluated using spin-echo (TR/TE=500/14 msec) and gradient-echo (FLASH) (TR/TE=80/4 msec, flip angle=60) techniques in 1.57 MR scanner. The images of rabbit liver were obtained every 10 minutes up to 4 hours. To study the effect of concentration on image, 20 mM, 50 mM, 100 mM of MnPC were tested. Results : The relaxivities of MnPC at 1.5T(64MHz) were Rl=7.28 $mM^{-1}S^{-1},{\;}R2=55.56mM^{-1}S^{-1}$. Compared to the values of Gd-DTPA (Rl[=4.8 $mM^{-1}S^{-1})$], R2[=5.2 $mM^{-1}S^{-1}])$]), both T1/T2 relaxivities of MnPC were higher than those of Gd-DTPA. For both of SE and FLASH techniques, the contrast enhancement reached maximum at 10 minutes after bolus injection and the enhancement continued for more than 2 hours. When compared with small molecular weight liver agents such as Gd-EOB-DTPA, Gd-BOPTA and MnDPDP, MnPC was characterized by more prolonged enhancement time. The time course of MR images also revealed biliary excretion of MnPC. Conclusion : We developed a new macromolecular MR agent, MnPC. The relaxivities of MnPC were higher than those of small molecular weight Gd-chelate. Hepatic uptake and biliary excretion of MnPC suggests that this agent is a new liver-specific MR agent.

  • PDF

The Evaluation of Optimized Inversion-Recovery Fat-Suppression Techniques for T2-Weighted Abdominal MR Imaging : Preliminary report (복부의 T2강조 영상에서 지방소거기법의최적의 평가)

  • Lee, Da-Hee;Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.31-35
    • /
    • 2012
  • To test the real image quality of a spectral attenuated inversion-recovery (SPAIR) fat-suppression (FS) techniquein clinical abdominal MRI by comparison to turbo spin echo inversion-recovery (TSEIR) fat-suppression (FS) technique. 3.0T MRI studies of the abdomen were performed in 30 patients with liver lesions (hemangiomas n: 15; HCC n: 15). T2W sequences were acquired using SPAIR TSEIR. Measurements included retroperitoneal and mesenteric fat signal-to-noise (SNR) to evaluate FS; liver lesion contrast-to-noise (CNR) to evaluate bulk water signal recovery effects; and bowel wall delineation to evaluate susceptibility and physiological motion effects. SPAIR-TSEIR images produce significantly improved FS and liver lesion CNR. The mean SNR of the retroperitoneal and mesenteric fat for SPAIR were 20.5, 10.2 and TSEIR were 43.2, 24.1 (P<0.05). SPAIR-TSEIR images produced higher CNR for both hemangiomas CNR 164.88 vs 126.83 (P<0.05) and metastasis CNR 75.27 vs 53.19 (P<0.05). Bowel wall visualization was significantly improved using in both SPAIR-TSEIR (P< 0.05). The real image quality of SPAIR was better than over conventional TSEIR FS on clinical abdominal MRI scans.

  • PDF

Pre-evaluation of Non-alcoholic Fatty Liver Disease Model Using Micro-MRI: For Big Data Application (비알콜성 간 질환 동물모델 영상 빅 데이터 구축을 위한 영상데이터 수집 및 사전평가)

  • Lee, Gi-Taek;Jun, Hong Young;Kim, Tae-Hoon;Jang, Mi Yeon;Kim, Dae Won;Yoon, Kwon-Ha
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.982-983
    • /
    • 2017
  • 본 연구는 최근 문제가 되고 있는 비알콜성 간 질환에 대한 빅 데이터의 사전 데이터를 만들기 위해 마우스에서 고지방 식이와 Streptozotocin ((STZ)로 모델을 제작하였고, 당뇨와 비만 정도를 측정하여 질환발생 정도를 확인하였다. 또한, MR영상의 지속적인 촬용으로 질환발생과정에 대해 3D분석 소프트웨어로 평가되었다.

Usefulness of the PRESS Technique using 3.0T Magnetic Resonance Spectroscopy for Evaluation of Non-Alcoholic Fatty Liver Disease Patients (비알콜성 지방간환자 평가를 위한 3.0T 고자기장 자기공명분광법을 이용한 PRESS 기법의 유용성)

  • Goo, Eun-Hoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5931-5936
    • /
    • 2012
  • This study was to evaluate the clinical usefulness of the PRESS technique based on the correlation between PRESS technique and biopsy results by applying 3.0T high magnetic field MRS technique for evaluation of non-alcoholic fatty liver disease patients. This experiment were carried out using a 3.0T magnetic resonance imaging equipment. The part data of each spectrum is taken by peak area integration. The part data of resonance peak was used to calculate relative ratio. MR spectral peak in patients with non-alcoholic fatty liver disease is from 0.9 to 1.6 ppm. According to MRS method study result, Patients with NAFLD were obtained with 94% sensitivity and 80% specificity(p=0.000). When compared to normal based on MRS and Biopsy results was valid correlation(r=0.79, p=0.04). Results for NAFLD(r=0.89, p=0.002) also showed a correlation. Therefore, PRESS technique to evaluate patients with non-alcoholic fatty liver disease, the distribution difference between normal liver and fatty liver part is significantly distinguished. Biopsy and MRS fatty liver peak ratio(%) proves high lipid over grade(r = 0.7).