• 제목/요약/키워드: Liquid transfer

검색결과 1,335건 처리시간 0.034초

고온용 히트파이프형 태양열 흡수기 (High-Temperature Heat-Pipe Type Solar Thermal Receiver)

  • 부준홍;정의국
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.668-671
    • /
    • 2007
  • A numerical study was conducted on a simplified model of a high-temperature solar receiver which incorporates liquid-metal heat pipe. The objective of this paper is to compare the isothermal characteristics of the heat pipe receiver with the conventional receiver utilizing convection of molten salt as heat carrier. The solar receiver was assumed to be subject to a concentration ratio between 50 and 1,000 to supply high-temperature heat to a stirling engine for electric power generation. For simplicity of the analysis, a cylindrical geometry was assumed and typical dimensions were used based on available literature. The heat pipe had a shape of double-walled cavity and the working fluid was a sodium. The analysis was performed assuming that the radiation heat flux on the inner walls of the receiver was uniform, since the focus of this study was laid on the comparison of the conventional type and heat pipe type receiver. The results showed that the heat pipe type exhibited superior performance when the operating temperature becomes higher. In addition, to explore the advantage of the heat pipe receiver, the channel shape and dimensions should be adjusted to increase the heat transfer area between the wall and the heat trnasfer medium.

  • PDF

액체로켓 터보펌프의 임계 속도 해석 (Critical Speed Analysis of the Liquid Rocket Turbopump)

  • 전성민;곽현덕;윤석환;김진한
    • 한국항공우주학회지
    • /
    • 제33권6호
    • /
    • pp.92-99
    • /
    • 2005
  • 30톤 추력급 터보펌프에 대한 회전체 동역학 해석이 수행되었다. 연료펌프와 터빈에 의해서 유발되는 공력 및 수력 하중이 볼 베어링과 비접촉식 실의 강성 및 감쇠 예측을 위하여 고려되었다. 임계 속도의 분리 안전 여유와 회전체 부품의 팁 변위를 예측하기 위하여 임계 속도 해석과 질량 불평형 응답 해석이 수행되었다. 정확한 해석을 위하여 3차원 유한요소법을 사용하였고 1차원 전달함수 행렬법의 결과와 비교하였다. 탄성 링을 추가적으로 장착함으로써 베어링 지지부의 강성 제어를 통하여 충분한 공진 분리 여유의 확보가 가능함을 확인하였다.

External and Internal Glucose Mass Transfers in Succinic Acid Fermentation with Stirred Bed of Immobilized Actinobacillus succinogenes under Substrate and Product Inhibitions

  • Galaction, Anca-Irina;Rotaru, Roxana;Kloetzer, Lenuta;Vlysidis, Anestis;Webb, Colin;Turnea, Marius;Cascaval, Dan
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권12호
    • /
    • pp.1257-1263
    • /
    • 2011
  • This paper is dedicated to the study on the external and internal mass transfers of glucose for succinic acid fermentation under substrate and product inhibitions using a bioreactor with stirred bed of immobilized Actinobacillus succinogenes cells. By means of the substrate mass balance for a single particle of biocatalysts, considering the kinetic model adapted for both inhibitory effects, specific mathematical models were developed for describing the profiles of the substrate concentration in the outer and inner regions of biocatalysts and for estimating the substrate mass flows in the liquid boundary layer surrounding the particle and inside the particle. The values of the mass flows were significantly influenced by the internal diffusion velocity and rate of the biochemical reaction of substrate consumption. These cumulated influences led to the appearance of a biological inactive region near the particle center, its magnitude varying from 0 to 5.3% of the overall volume of particles.

소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계 (Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR)

  • 김낙현;이사용;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

소량의 기포를 함유한 이상유체 내에서의 압력파의 전파현상 (Pressure Wave Propagation Phenomena in Water Containing Uniformly Distributed Gas Bubbles)

  • 김동혁
    • 한국음향학회지
    • /
    • 제8권1호
    • /
    • pp.23-30
    • /
    • 1989
  • 기포 혼합 유체 내에서의 압력파의 전파 현상을 수치해석으로 연구한다. 혼합 유체 영역을 지배하는 지배 방정식을 heuristic 한 방법으로 유도하고 기포 내부 영역에는 열전달 효과를 고려할 수 있도록 에너지 방정식을 도입한다. 기포 내부의 비등온 조건은 특히 기포가 고진폭을 가지고 진동할 때 매우 중요하다. 기포 역학 방정식으로서 Keller 방정식이 채택, 변형되어 기포 외부와 내부의 coupling을 맺어준다. 실제 문제로서 충격관내 충격파의 전파 현상을 수치해석 방법으로 해석한 결과가 Noordzij 및 van Wijngaarden 의 실험 결과와 거의 일치한다. 그러나 그들에 의해 설명된 충격파 구조의 변화 원인은 가스와 액체 간의 상대 운동인데 이는 본 모델에서 고려되지 않았기 때문에 가스와 액체 간의 열전달에 의해 충격파의 구조가 변화된다고 보는 것이 타당하다.

  • PDF

염료태양전지용 고온안정성 전해질 (High Temperature Stable Eletrolyte for Dye Solar Cell)

  • 한치환;이학수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.220-224
    • /
    • 2009
  • The effect of addition of single and binary additives on the performance of dye-sensitized $TiO_2$ solar cells based on 1,2-dimethyl-3-propylimidazolium iodide (DMPII) in ethylene carbonate (EC) and gamma-butyrolactone (GBL) has been evaluated at different cell temperatures in the $30-120^{\circ}C$ range. The electrolyte containing a single additive, 2-(dimethylamino)-pyridine (DMAP) showed best performance, which showed further enhancement for an electrolyte containing binary additives, DMAP and 5-chloro-1-ethyl-2-methylimidazole (CEMI) in equal molar ratio. The performance of the dye sensitized solar cell (DSC) based on electrolyte containing binary additives were found to be better than an acetonitrile based electrolyte. The dependence of different photovoltaic parameters (Voc, Jsc, ff, n) of the DSC upon temperature has been studied over the $30-120^{\circ}C$ range and only a small decrease in conversion efficiency has been observed. Thus the electrolyte containing binary additives (DMAP, CEMI) in EC/GBL solvent and show better performance in the investigated temperature range ($30-120^{\circ}C$).

  • PDF

유효열이송거리가 고온 태양열기기용 액체금속 히트파이프의 열전달 특성에 미치는 영향 (Influence of the Effective Thermal Thansport Length on the Heat Transfer Characteristics of a Liquid-Metal Heat Pipe for High-temperature Solar Thermal Devices)

  • 박철민;부준홍;김진수;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.220-225
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Two layers of stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. The effective heat transport length, the thermal load, and the operating temperature were varied as thermal transport conditions of the heat pipe. The thermal load was supplied by an electric furnace up to 1kW and the cooling was performed by forced convection of air The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total effective thermal conductivity was as low as 43,500 W/m K for heat flux of 176.4 kW/$m^2$ and of operating temperature of 1000 K.

  • PDF

STATUS OF PYROPROCESSING TECHNOLOGY DEVELOPMENT IN KOREA

  • Song, Kee-Chan;Lee, Han-Soo;Hur, Jin-Mok;Kim, Jeong-Guk;Ahn, Do-Hee;Cho, Yung-Zun
    • Nuclear Engineering and Technology
    • /
    • 제42권2호
    • /
    • pp.131-144
    • /
    • 2010
  • The Korea Atomic Energy Research Institute (KAERI) has been developing pyroprocessing technology for recycling useful resources from spent fuel since 1997. The process includes pretreatment, electroreduction, electrorefining, electrowinning, and a waste salt treatment system. This paper briefly addresses unit processes and related innovative technologies. As for the electroreduction step, a stainless steel mesh basket was applied for adaption of granules of uranium oxide. This basket was designed for ready handling and transfer of feed material. A graphite cathode was used for the continuous collection of uranium dendrite in the electrorefining system. This enhances the throughput of the electrorefiner. A particular mesh type stirrer was designed to inhibit uranium spill-over at the liquid Cd crucible. A residual actinide recovery system was also tested to recover TRU tracer. In order to reduce the waste volume, a crystallization method is employed for Cs and Sr removal. Experiments on the unit processes were tested successfully, and based on the results, engineering-scale equipment has been designed for the PRIDE (PyRoprocess Integrated inactive DEmonstration facility).

미분무수 분사 특성에 따른 가열 챔버 내 냉각 성능 수치 해석 (Numerical Analysis of Effects of Water Mist Injection Characteristics on Cooling Performance in Heated Chamber)

  • 수먼;이상욱
    • 한국분무공학회지
    • /
    • 제17권2호
    • /
    • pp.64-70
    • /
    • 2012
  • Water mist fire suppression systems which use relatively small droplets of water with high injection pressure are increasingly being used in wider applications because of its greater efficiency, low flooding damage and low toxicity. However, the performance of the system significantly relies on the water mist characteristics and it requires better understanding of fire suppression mechanism of water mist. In the present study, computational fluid dynamics simulations were carried out to investigate cooling performance of water mist in heated chamber. The gas phase was prepared with natural convection heat transfer model for incompressible ideal case and then the effects of water mist injection characteristics on cooling capabilities were investigated upon the basis of the pre-determined temperature field. For the simulation of water mist behavior, Lagrangian discrete phase model was employed by using a commercial code, FLUENT. Smaller droplet sizes, greater injection angles and higher flow rates provided relatively higher cooling performance.

연료 종류 및 당량비에 따른 Flame Spray 화염장의 열-유동 특성 연구 (Thermal and Flow Characteristics of Fluid with Fuel Type and Equivalence Ratio in Flame Spray Process)

  • 이재빈;김대윤;신동환;이성혁
    • 한국분무공학회지
    • /
    • 제18권4호
    • /
    • pp.202-208
    • /
    • 2013
  • The present study aims to investigate the flow characteristics with respect to fuel type and equivalence ratio in the flame spray coating process. The flame spray flow is characterized by much complex phenomena including combustion, turbulent flows, and combined heat transfer. The present study numerically simulated the flam spray process and examined the gas dynamics involving combustion, gas temperature and velocity distributions in flame spray process by using commercial computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). In particular, we studied the effect of fuel type and equivalence ratio on thermal and flow characteristics which could substantially affect the coating performance. From the results, it was found that the gas temperature distributions were varied with different fuels because of reaction times were different according to the fuel type. The equivalence ratio also could change the spatial flame distribution and the characteristics of coated layer on the substrate.