• 제목/요약/키워드: Liquid chromatography-mass

검색결과 1,084건 처리시간 0.03초

High-Performance liquid Chrmatogrphic and Tandem Mass Spectrometric Quantitation of N7-Methyldeoxyguanosin in Methylated Calf Thymus DNA

  • Chae, Whi-Gun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제5권3호
    • /
    • pp.191-195
    • /
    • 2000
  • Quantitation of N7-methyldeoxyguanosine (N7-MedG) produced in the in vitro N-methly-N-nitrosuourea (NMU) action on thymus DNA has been achieved by enzymatic degradation, liquid chromatoraphic separaphic separation and desorption chemical ionization tandem mass spectrometry. In conjunction with the resolving power HPLC in the separation of isomers, desorprion chemical ionization tandem mass spectrometry has utilized in determining modified nucleosides at low levels using a stable-isotope labled compound as an internal reforence. The quantitative estimation of N7-methyldeoxyguanosine was previously established by an independent HPLC analysis of methylated calf thymus DNA. A sensitive and specific methodogy for the quantitation of N7-MedG at the picomole level using HPLC combined with tandem mass spectrometry without radioisotope labeling process is presented. The potential of the liquid chromatoraphic tandem mass exposure to methlation agents in vitro.

  • PDF

A comparison study of extraction methods for bio-liquid via hydrothermal carbonization of food waste

  • Bang, YeJin;Choi, Minseon;Bae, Sunyoung
    • 분석과학
    • /
    • 제31권3호
    • /
    • pp.112-121
    • /
    • 2018
  • The hydrothermal carbonization method has received great attention because of the conversion process from biomass. The reaction produces various products in hydrochar, bio-liquid, and gas. Even though its yield cannot be ignored in amount, it is difficult to find research papers on bio-liquid generated from the hydrothermal carbonization reaction of biomass. In particular, the heterogeneity of feedstock composition may make the characterization of bio-liquid different and difficult. In this study, bio-liquid from the hydrothermal carbonization reaction of food wastes at $230^{\circ}C$ for 4 h was investigated. Among various products, fatty acid methyl esters were analyzed using two different extraction methods: liquid-liquid extraction and column chromatography. Different elutions with various solvents enabled us to categorize the various components. The eluents and fractions obtained from two different extraction methods were analyzed by gas chromatography with a mass spectrometer (GC/MS). The composition of the bio-liquid in each fraction was characterized, and seven fatty acid methyl esters were identified using the library installed in GC/MS device.

Identification of Actinomycins by High Performance Liquid Chromatography and Fast Atom Bombardment Mass Spectrometry

  • Cho, Seong-Eun;Goo, Yang-Mo;Kim, Kyoung-Ja
    • Archives of Pharmacal Research
    • /
    • 제17권6호
    • /
    • pp.424-427
    • /
    • 1994
  • An acinomycin complex isolated from culture broth of a soil microorganism, SNUS 9305-011 has been examined by High performance liquid chromatography (HPLC). From the analysis of the fractions obtained by column chromatography of the ethyl acetate extract, three actinomycin components are confimed . The HPLC analysis is carried out with a CN-bonded nucleosil column. Comparison of the retention times of the components with those of actinomycin D, C complex, $X_{o{\beta}$, and V and suggests that they are different actinomycins. FBA mass spectra fo the coponents also shows different molecular ions from those of standards and other reported actionbmycins. The present work has demonstrated that actinomycin components can be separated by a CN-bonded HPLC column, and that ocmparison of their HPLC chormatograms with authentic smaples and information on their molecular ions can be successfully employed for indentification of actionmycins.

  • PDF

몇가지 박과 식물 종자유중의 Sterol 조성 (Sterol Compositions in Some Cucurbitaceae Vegetable Oils)

  • 정태명;양민석
    • 대한화학회지
    • /
    • 제21권3호
    • /
    • pp.193-203
    • /
    • 1977
  • 오이, 수박, 수세미, 박, 하늘수박의 다섯가지 박과식물 종자유에서 세가지 스테롤 플랙숀을 박층 크로마토그래피로 나누고 각 플랙숀의 조성을 가스크로와 가스크로에 연결된 질량분석법으로 밝혔다. 이중 4-데스메틸스테롤 플랙숀에서 ${\alpha}$-Spinasterol, ${\Delta}^{7,22,25}$-stigmastatrienol 및 ${\Delta}^{7,25}$-stigmastadienol를 단리(單離)하여 IR, NMR 및 질량분석법으로 동정(同定)하였다.

  • PDF

GC/MS를 이용한 뇨 중 환경 에스트로겐들의 동시 프로필 (Profiling of Urinary Environmental Estrogens by Gas Chromatography/Mass Spectrometry)

  • 양윤정;이선화;정봉철
    • 분석과학
    • /
    • 제12권4호
    • /
    • pp.265-272
    • /
    • 1999
  • 에스트로겐처럼 행동하여 호르몬 수용체와 결합하거나 세포의 신호전달 과정에 영향을 미침으로서 내분비계를 교란시킬 수 있는 환경 에스트로겐 19종 (phytoestrogen: 12종, mycoestrogen: 5종, synthetic estrogen: 2종)의 동시 프로필 분석을 시도하였다. Gas Chromatography/Mass Spectrometry (GC/MS)의 selected ion monitoring (SIM) 방법을 기본으로 하였으며, 액체-고체 추출, 효소 기수분해, 액체-액체 추출 그리고 trimethylsilyl (TMS)-ether 형태의 유도체화를 거치는 비교적 간편한 전처리 방법으로 47.6~99.5%의 회수율과 0.66~9.33%, 1.66~16.14%의 within-a-day 및 day-to-day 분석의 RSD 값을 얻었다. 이 방법을 적용하여 정상 성인 여성과 남성의 뇨 시료에 존재하는 대상 물질들의 농도범위를 결정함으로서 환경 에스트로겐의 영향을 평가하는데 기준이 될 수 있는 한국인 정상인 참고치를 설정하였다.

  • PDF

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • 제5권1호
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.

An Evaluation of Liquid Chromatography/Mass Specrometry with Atmospheric Pressure Chemical Ionizarion for the Rapid and Simultaneous Measurement of Carbamate Pesticides and Organophosphorus Pesticides

  • 김병주;소현영
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권5호
    • /
    • pp.471-476
    • /
    • 2000
  • Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtrained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 ㎍/mL. Teh peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to run. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng.

Analysis of Entamoeba histolytica Membrane via LC-MALDI-TOF/TOF

  • Ujang, Jorim Anak;Noordin, Rahmah;Othman, Nurulhasanah
    • Mass Spectrometry Letters
    • /
    • 제10권3호
    • /
    • pp.84-87
    • /
    • 2019
  • Liquid chromatography mass spectrometry is widely employed in proteomics studies. One of such instruments is the Liquid Chromatography (LC)-Matrix-assisted laser desorption ionisation (MALDI)-Time of flight (TOF) or LC-MALDI-TOF/TOF. In this study, this instrument was used to identify the membrane proteins of a protozoan parasite namely Entamoeba histolytica. It causes amoebiasis in human. The E. histolytica trophozoites were cultured prior to the membrane protein extraction using the conventional method, $ProteoPrep^{(R)}$ and $ProteoExtract^{(R)}$ kits. Then, the membrane protein extracts were trypticdigested and analysed by LC-MALDI-TOF/TOF. Approximately, 194 proteins were identified and 27.8% (54) were predicted as membrane proteins having 1 to 15 transmembrane regions and signal peptides by combining all three extraction methods. Also, this study has discovered 3 unique proteins as compared to our previous study which merit further investigation.

Determination of a Novel Antiangiogenic Agent KR-31831 in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry

  • Kim, Sook-Jin;Lee, Seung-Seok;Ji, Hye-Young;Lee, Hong-Il;Lee, Seon-Kyoung;Yi, Kyu-Yang;Yoo, Seong-Eun;Hwang, Jeong-Sook;Lee, Hye-Suk
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.217.2-217.2
    • /
    • 2003
  • A liquid chromatography-tandem mass spectrometric (LC/MS/MS) method was developed for the determination of a new anti-angiogenic drug KR-31831 in rat plasma. KR-31831 and internal standard, KR-31543 were extracted from rat plasma with dichloromethane at basic pH. A reverse-phase LC separation was performed on Luna C8 column with the mixture of acetonitrile-ammonium formate (10 mM, pH 4.5) (67:33, v/v) as mobile phase. The detection of analytes was performed using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. (omitted)

  • PDF