• Title/Summary/Keyword: Liquid by-product

Search Result 575, Processing Time 0.026 seconds

Discrimination of biological and artificial nicotine in e-liquid

  • Hyoung-Joon Park;Heesung Moon;Min Kyoung Lee;Min Soo Kim;Seok Heo;Chang-Yong Yoon;Sunyoung Baek
    • Analytical Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.22-31
    • /
    • 2023
  • As the use of e-liquid cigarettes is rapidly increasing worldwide, it multiplies the potential risk undisclosed to the health of non- and smokers. To reduce the hazard, each country has its own set of regulations for controlling e-liquids. In Korea, the narrow definition of tobacco makes it difficult and have been steadily occurring tax evasion exploiting the difference in natural and artificial nicotine. Therefore, it is very important to distinguish source of nicotine for their regulation. To find biochemical discriminant markers, this study established analysis methods based on high-performance liquid chromatography coupled with diode array detector (HPLC-DAD) and high-performance liquid chromatography coupled with triple Quadrupole mass spectrometry (HPLC-MS/MS) for nicotine enantiomers and tobacco alkaloids targeted using the difference in pathways of nicotine biosynthesis and chemical synthesis. The method was validated by experimenting linearity (R2 > 0.999), recovery (80.99-108.41 %), accuracy (94.11-109.73 %) and precision (0.04-8.27 %). Then, the results for discrimination of the nicotine obtained from analysis of 65 commercial e-liquid products available in Korean market was evaluated. The method successfully applied to the e-liquids and one sample labelled 'synthetic nicotine' for tax exemption was found to contain a natural nicotine product. This method can be used to determine whether an e-liquid product uses natural or artificial nicotine and monitor non-taxable e-liquid products. The method is more scientific than the existing one, which relies only on field evidence.

Product Distribution Characteristics of High-Impact Polystyrene Depolymerization by Pyrolysis (열분해에 의한 내충격 폴리스티렌 해중합 생성물의 분포 특성)

  • Lee, Bong-Hee;Yu, Hong-Jeong;Kim, Dae-Su
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.64-68
    • /
    • 2005
  • To recycle collected high-impact polystyrene (HIPS) wastes as liquid fuel, depolymerization characteristics of HIPS by pyrolysis was studied. The effects of temperature and time on the pyrolysis of HIPS were investigated. The depolymerization temperature and activation energy of HIPS pyrolysis increased with increasing heating rate. In general, conversion and liquid yield gradually increased with pyrolysis temperature and pyrolysis time. Each liquid product formed during pyrolysis was classified into gasoline, kerosene, light oil and heavy oil according to the distillation temperature based on the petroleum product quality standard of Korea Petroleum Quality Inspection Institute. As a result, the amount of liquid products produced during HIPS pyrolysis was in the order of gasoline》heavy oil〉kerosene〉light oil. Especially 51${\pm}$6 wt% of HIPS treated was obtained as gasoline.

Pyrolysis of Polyethylene using Batch Microreactor (회분식 미분반응기를 이용한 폴리에틸렌의 열분해특성 연구)

  • CHa, Wang-Seog;Kim, Sang-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.553-556
    • /
    • 2005
  • Pyrolysis of polyethylene was carried out in the stainless steel reactor of internal volume of $40cm^3$. Pyrolysis reactions were performed at temperature $390-450^{\circ}C$ and the pyrolysis product were collected separately as reaction products and gas products. The molecular weight distributions(MWDs) of each liquid product were determined by GC-SIMDIS. Molecular weight of each product were decreased wi th increase of react ion temperature and time.

  • PDF

Super High Contrast Ratio of TN mode TFT- LCD by Taguchi Design

  • Huang, Y.J.;Chao, Andy;Huang, K.T.;Hung, Y.W.;Yu, C.H.;Wu, H.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1652-1655
    • /
    • 2008
  • A new high contrast LCD structure for TN mode TFT-LCD, of which the contrast ratio is 1.2 times hi gher than that of the conventional one, has been developed. The contrast ratio of TFT-LCD display can be improved by some modified materials, which like as polarizer, liquid crystal, color filter and light enhancement film. In order to know which condition can get the major contribution for the upgrade of the contrast ratio, we used Taguchi method and analyzed the contribution ratio for each composition and succeed to build up the formula of contrast ratio. From this study, we could achieve the highest CR value as 1200:1 of TN mod e TFT-LCD nowadays.

  • PDF

Analysis of fatty acid methyl ester in bio-liquid by hollow fiber-liquid phase microextraction

  • Choi, Minseon;Lee, Soyoung;Bae, Sunyoung
    • Analytical Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.174-181
    • /
    • 2017
  • Bio-liquid is a liquid by-product of the hydrothermal carbonization (HTC) reaction, converting wet biomass into solid hydrochar, bio-liquid, and bio-gas. Since bio-liquid contains various compounds, it requires efficient sampling method to extract the target compounds from bio-liquid. In this research, fatty acid methyl ester (FAME) in bio-liquid was extracted based on hollow fiber supported liquid phase microextraction (HF-LPME) and determined by Gas Chromatography-Flame Ionization Detector (GC-FID) and Gas Chromatography/Mass Spectrometry (GC/MS). The well-known major components of biodiesel, including methyl myristate, palmitate, methyl palmitoleate, methyl stearate, methyl oleate, and methyl linoleate had been selected as standard materials for FAME analysis using HF-LPME. Physicochemical properties of bio-liquid was measured that the acidity was 3.30 (${\pm}0.01$) and the moisture content was 100.84 (${\pm}3.02$)%. The optimization of HF-LPME method had been investigated by varying the experimental parameters such as extraction solvent, extraction time, stirring speed, and the length of HF at the fixed concentration of NaCl salt. As a result, optimal conditions of HF-LPME for FAMEs were; n-octanol for extraction solvent, 30 min for extraction time, 1200 rpm for stirring speed, 20 mm for the HF length, and 0.5 w/v% for the concentration of NaCl. Validation of HF-LPME was performed with limit of detection (LOD), limit of quantitation (LOQ), dynamic range, reproducibility, and recovery. The results obtained from this study indicated that HF-LPME was suitable for the preconcentration method and the quantitative analysis to characterize FAMEs in bio-liquid generated from food waste via HTC reaction.

Detection of 1,4-Dihydroxy-2-Naphthoic Acid from Commercial Makgeolli Products

  • Eom, Ji-Eun;Kwon, Sang-Chul;Moon, Gi-Seong
    • Preventive Nutrition and Food Science
    • /
    • v.17 no.1
    • /
    • pp.83-86
    • /
    • 2012
  • To support beneficial effects of makgeolli for human health, we investigated for the presence of 1,4-dihydroxy-2-naphthoic acid (DHNA), a bifidogenic growth stimulator (BGS), from commercial makgeolli products. Among eleven makgeolli products (A~K), four showed positive peaks for DHNA in high performance liquid chromatography analysis. Makgeolli product A in particular contained the highest concentration of DHNA (0.44 ppm), as confirmed by liquid chromatography-mass spectrometry. Furthermore, BGS activity of the makgeolli product A was higher than those of products in which DHNA was not detected. These results indicate that makgeolli can be a good source for DHNA and that DHNA-enriched makgeolli could be developed by modifying manufacturing procedures and controlling its microbiota.

Liquefaction Characteristics of PP by Pyrolysis (PP의 열분해에 의한 액화 특성)

  • Yu, Hong-Jeong;Lee, Bong-Hee;Park, Su-Yul
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.258-264
    • /
    • 2002
  • Pyrolysis of polypropylene(PP) Was performed to find the effects of the pyrolysis temperature(425, 450, 475 and $500^{\circ}C$) and the pyrolysis time(35, 50 and 65minutes), respectively. Conversion and liquid yield obtained during PP pyrolysis continuously increased with the pyrolysis temperature( up to $500^{\circ}C$) and the pyrolysis time(up to 65minutes), especially these were more sensitive to the pyrolysis time at $425^{\circ}C$ than other pyrolysis temperatures. Each liquid product formed during the pyrolysis was classified into gasoline, kerosene, light oil and wax according to the distillation temperature based on the petroleum product quality standard of Korea Petroleum Quality Inspection Institute. The liquid products of PP pyrolysis up to $450^{\circ}C$ were almost same fractions($26{\pm}3$wt.% gasoline, $20{\pm}2$wt.% kerosene and $23{\pm}2$wt.% light oil) except wax($3{\sim}13$wt.%). On the other hand, the pyrolysis of PP from $475^{\circ}C$ to $500^{\circ}C$ produced $26{\pm}3$wt.% wax, $24{\pm}1$wt.% gasoline, $18{\pm}1$wt.% kerosene and $16{\pm}1$wt.% light oil. After all, the main liquid product changed from gasoline to wax with increasing pyrolysis temperature.

Rapid Identification of Radical Scavenging Compounds in Blueberry Extract by HPLC Coupled to an On-line ABTS Based Assay and HPLC-ESI/MS

  • Kim, Chul-Young;Lee, Hee-Ju;Lee, Eun-Ha;Jung, Sang-Hoon;Lee, Dong-Un;Kang, Suk-Woo;Hong, Sae-Jin;Um, Byung-Hun
    • Food Science and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.846-849
    • /
    • 2008
  • This study employed high performance liquid chromatography (HPLC) coupled to an on-line $ABTS^+$ radical scavenging detection (RSD) system along with HPLC-electro spin impact/mass spectrometry (ESI/MS), to rapidly determine and identify antioxidant compounds occurring in blueberry extract. The extract was separated by HPLC, and then the radical scavenging activities of the separated compounds were evaluated by the on-line coupled $ABTS^+$-RSD system. The negative peaks of the $ABTS^+$-RSD system, which indicates the presence of antioxidant activity, were monitored by measuring the decrease in absorbance at 734 nm. The active components in the blueberry extract were identified by HPLC-ESI/MS using their MS spectra and retention times. According to the data acquired from the on-line HPLC-$ABTS^+$-based assay and HPLC-ESI/MS systems, the antioxidant compounds detected in the blueberry extract were identified as chlorogenic acid and 11 anthocyanins.

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.

Kinetics of the Low-temperature Pyrolysis of Mixed Plastics in the Batch Reactor (회분식반응기에서의 혼합 플라스틱의 저온열분해 kinetics)

  • Cha, Wang Seog;Oh, Myung Seog;Jang, Hyun Tae;Tae, Beomseok
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.540-544
    • /
    • 2008
  • Pyrolytic characteristics of mixed plastics containing 22 wt.% HDPE, 17 wt.% LDPE, 27 wt.% PP, 12 wt.% PS, 16 wt.% ABS, 6 wt.% PVC have been studied in the batch-type microreactor of stainless steel. Thermal degradation experiments were performed at temperature of $410{\sim}450^{\circ}C$. The yield of each pyrolytic products were obtained by the weight measurement and molecular weight distribution of pyrolytic liquid products determined by the GC-SIMDIS method. It was shown that the yield and molecular weight of pyrolytic liquid product were decreased with the increase of reaction temperature and time. It was know that 20wt% of PVC composing of the mixed plastics was converted to the gas products of chloride during the pyrolysis process. The chain-end scission rate parameter was determined to be 50.2 kcal/mole of mixed plastics by the Arrhenius plot.