• Title/Summary/Keyword: Link switching

Search Result 462, Processing Time 0.03 seconds

Double Two Switch Forward Transformer-Linked Soft-Switching PWM DC-DC Power Converter with Tapped Inductor Filters

  • Moisseev Serguei;Koudriavtsev Oleg;Hiraki Eiji;Nakamura Mantaro;Nakaoka Mutsuo;Hamada Satoshi
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.193-197
    • /
    • 2001
  • This paper presents a novel circuit topology of the double two-switch forward type high frequency transformer linked soft-switching PWM DC-DC power converter with tapped inductor filters that can operate under a condition of the low peak voltage stress across the power semiconductor devices and lowered peak current stress through the transformer for some high power applications. This circuit topology of an interleaved two-switch forward soft-switching power converter is proposed in the order to minimize an idle circulating current due to the tapped inductor filter without of any additional active auxiliary resonant-assisted snubber circuits, such as active resonant DC link snubbers and AC link snubbers, active resonant commutation leg link snubbers. The unique advantages of this power converter are less power circuit components and power semiconductor devices, constant frequency PWM scheme, cost effective configuration and wider soft-switching PWM operation range under PWM power regulations load variations. The practical effectiveness of the proposed soft-switching converter circuit topology is tested by simulations and is proved by experimental results received from the 500W-100kHz breadboard setup.

  • PDF

Performance Analysis of Multi-Link Switching Method with Concurrent Processing Function (병행처리 기능을 갖는 멀티링크 스위칭기법의 성능 분석)

  • 유동관
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.2
    • /
    • pp.84-89
    • /
    • 2001
  • In this paper, an improved protocol of Multi-Link Switching Method is proposed by supplementing a concurrent processing function. This protocol is proposed to complement the shortcomings of the conventional Multi-Link Switching Method which is used for the medium access in LAN. We analyzed the improved protocol in channel utilization viewpoint and compared the result with that of the conventional protocol From this result, we showed that the channel utilization of the improved protocol is superior to that of the conventional protocol when the maximum normalized propagation delay is increased.

Resonance initial current compensation for Resonant DC-Link inverter (공진 DC-Link 인버터의 공진 초기전류의 보상에 관한 연구)

  • Kwak, Dong-Kurl;Suh, Ki-Young;Kwon, Soon-Kurl;Lee, Hyun-Woo;Woo, Jung-ln
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1136-1141
    • /
    • 1992
  • This paper proposes a control technique to obtain high frequency quasi sinusoidal DC-Link waveform permitting zero-voltage-switching(ZVS). This operation results in reduction of commutation stress and switching losses in the power devices because they cause no switching loss in principle. But in existing control methods, the resonant capacitor voltage is not frequently made of zero-cross oscillation. We propose an optimum control stratege which can sustain oscillation and keep the capacitor voltage at an allowable level. Some experimental results are included to confirm the validity of the analytical results.

  • PDF

An Inductive-coupling Link with a Complementary Switching Transmitter and an Integrating Receiver

  • Jeong, Youngkyun;Kim, Hyun-Ki;Kim, Sang-Hoon;Kwon, Kee-Won;Chun, Jung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.227-234
    • /
    • 2014
  • A transceiver for a high-speed inductive-coupling link is proposed. The bi-phase modulation (BPM) signaling scheme is used due to its good noise immunity. The transmitter utilizes a complementary switching method to remove glitches in transmitted data. To increase the timing margin on the receiver side, an integrating receiver with a pre-charging equalizer is employed. The proposed transceiver was implemented via a 130-nm CMOS process. The measured timing window for a $10^{-12}$ bit error rate (BER) at 1.8 Gb/s was 0.33 UI.

Feedback Burst Loss Ratio Control for Link Performance Improvement in Optical Bur st Switching Networks

  • Linh, To Hoang;Yoon, Gwi-Ok;Nam, Jae-Hyun;Solongo, Ganbold;Hwang, Won-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.9
    • /
    • pp.1067-1076
    • /
    • 2013
  • Known as an important criterion that evaluates performance of future high-speed backbone networks, burst data loss ratio is well-studied in Optical Burst Switching networks. Current literatures mostly focus on reduce burst loss ratio without considering the system stability and link utilization after reducing. In this paper, we propose a novel framework which comes from feedback theoretic to dynamically control burst loss ratio in OBS. The proposed scheme tries to track the pre-set values of burst loss ratio and increases the stability and link utilization degree. The simulation results show that measured burst loss ratio always tracks setup reference with small errors, wavelength channel utilization is increased up to 2% and the system stability is also improved.

A Novel Three-Phase Quasi-Resonant DC Link Inverter (새로운 3상 준공진 직류링크 인버터)

  • Lee, Jin-Woo;Park, Min-Ho;Won, Jong-Soo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.5
    • /
    • pp.479-488
    • /
    • 1991
  • A novel three-phase quasi-resonant dc link inverter (QRI)with a switch connected between dc voltage source and resonant inductor is proposed. According to the state of switching and load current, the operating mode of the proposed inverter scheme is classified into free-wheeling, inverting, and rectifying mode. By examining the behavior of the circuit in each operating mode, an equivalent circuit which represents all the modes in a unified manner is derived. The operating principle of QRI at inverting mode is analyzed, and it is shown that the maximum voltage of resonant dc link is confined to twice the dc source voltage and that both the zero voltage switching of inverter and the zero current switching of inserted switch are guaranteed. An appropriate current control algorithm is suggested, and the opeating characteristics of proposed resonant inverter are verified through both simulation and experiment.

  • PDF

Novel Three-Phase PWM Voltage-Fed Rectifier with an Auxiliary Resonant Commutated Pole Link

  • Qu, Ke-Qing;Zhao, Jin-Bin
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.678-686
    • /
    • 2014
  • A novel auxiliary resonant commutated pole (ARCP) link for three-phase PWM voltage-fed converter is presented. The ARCP link consists of two auxiliary switches, one resonant inductance, and six diodes, which is simpler than the conventional ARCP designs. Based on the phase and amplitude control, the proposed converter can take a minimum switching times PWM method, which results in reduced losses and a simplified control. In addition, the zero-voltage resonance modes are analyzed. Finally, simulation and experimental results show that the system can realize zero-voltage switching with a unity power factor.

The Experimental Consideration about Loss of Three-phase Voltage-fed Inverter using Auxiliary Resonant DC Link (ARDCL을 이용한 3상 전압형 인버터의 손실에 관한 실험적 고찰)

  • 서기영;문상필;김주용;이상현;박영조
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.100-105
    • /
    • 2003
  • This paper proposes a new auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually-measured conduction loss characteristic of switching device module. Voltage-fed soft switching three-phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three-phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

Optimal Design of Notch Filter in Photovoltaic Inverter (태양광 인버터의 노치 필터 최적 설계)

  • Kim, Yong-Rae;Heo, Cheol-Young;Lee, Young-Kwoun;Choy, Ick;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.81-92
    • /
    • 2019
  • When Photovoltaic inverter is connected to grid and used as PVPCS (Photovoltaic Power Conditioning System), 120 Hz AC ripple occurs at the dc-link capacitor voltage. This AC ripple reduces the efficiency of PVPCS and shortens the lifetime of the capacitor. In this paper, we design a notch filter to remove AC ripple. As a result, the AC voltage ripple was removed from the dc link and the THD of the PVPCS output current with the notch filter was lowered. This notch filter is determined by the damping coefficient, the bandwidth coefficient, and the switching frequency. Among these, the switching frequency determines the switching loss and the size of the LC filter, and the PVPCS with the high switching frequency has a greater efficiency loss due to the switching loss than the efficiency improvement by the notch filter. Therefore, it is important to set the optimum switching frequency in the PVPCS with the notch filter applied. In this paper, THD and switching loss of PVPCS output current with notch filter are calculated through simulation, and cost function to calculate optimum switching frequency through data is proposed.

Utility Interactive Solar Power Conditioner with Zero Voltage Soft Switching High frequency Sinewave Modulated Inverter Link

  • Terai H.;Sumiyoshi S.;Kitaizumi T.;Omori H.;Ogura K.;Chandhaket S.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.668-672
    • /
    • 2001
  • The utility interactive sinewave modulated inverter for the solar photovoltaic (PV) power conversion and conditioning with a new high frequency pulse modulated link is presented for domestic residential applications. As compared with the conventional full-bridge hard switching PWM inverter with a high frequency AC link, the simplest single-ended quasi-resonant soft switching sinewave modulated inverter with a duty cycle pulse control is implemented, resulting in size and weight reduction and low-cost. This paper presents a prototype circuit of the single-ended zero voltage soft switching sinewave inverter for solar power conditioner and its operating principle. In addition, this paper proposes a control system to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed from an experimental point of view. A newly developed interactive sinewave power processor which has $92.5\%$ efficiencty at 4kW output is demonstrated. It is designed 540mm-300mm-125mm in size, and 20kg in weight.

  • PDF