• Title/Summary/Keyword: Link speed

Search Result 701, Processing Time 0.026 seconds

M/B-MC/CDMA performance analysis for high speed data transmission in IS-95 evolution (IS-95 진화방안에서 고속 데이터 전송을 위한 M/B-MC/CDMA 전송방식의 성능분석)

  • 임명섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10A
    • /
    • pp.1494-1500
    • /
    • 1999
  • In order to provide high speed multimedia data rate service, Multi-Code CDMA has been proposed which converts high speed serial data stream into N parallel low speed data streams with orthogonal PN codes for spreading. However this signal has multi level and causes interferences to be increased at the neighboring cell boundary in the reverse link. Therefore in order to solve the above mentioned problem, M/B-MC/CDMA, in which multi level signal is converted to binary level signal using M/B conversion, is proposed and the performance is compared with MC-CDMA.

  • PDF

A Study on the Improvement of Transmission Speed of Data Link Processor (전술데이터링크 처리기의 전송 속도 개선에 대한 연구)

  • Lee, Kang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1069-1076
    • /
    • 2019
  • With the development of information and communication technology, the military's battle environment is changing greatly to network centric warfare in where weapon system is connected in a network and carries out mission by exchanging the real-time data. The core of the network centric warfare is Tactical Data Link(TDL) system, and subscribers of TDL exchange tactical information in real time through wireline, wireless and satellite network to share the battlefield situation. The amount of data sent and received through TDL inevitably increase as military's weapon systems equipped with TDL systems increase over time and the performance of communications equipment improves. This study proposes ways to improve the transmission speed and processing capacity of the TDL system by improving the Data Link Processor.

A $0.18{\mu}m$ CMOS 3.2-Gb/s 4-PAM Serial Link Receiver Using Current Mode Signaling (Current Mode Signaling 방법을 이용한 $0.18{\mu}m$ CMOS 3.2-Gb/s 4-PAM Serial Link Receiver)

  • Lee, Jeong-Jun;Jeong, Ji-Kyung;Burm, Jin-Wook;Jeong, Young-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.10
    • /
    • pp.79-85
    • /
    • 2009
  • The design of a 3.2 Gb/s serial link receiver in $0.18{\mu}m$ CMOS process is presented. The major factors limiting the performance of high-speed links are transmission channel bandwidth, timing uncertainty. The design uses a multi-level signaling(4-PAM) to overcome these problems. Moreover, to increase data bit-rate and lower BER, we designed this circuit by using a current mode amplifier, Current-mode Logic(CML) sampling latches. The 4-PAM receiver achieves 3.2 Gb/s and BER is less than $1.0\;{\times}\;10^{-12}$. The $0.5\;{\times}\;0.6\;mm^2$ chip consumes 49 mA at 3.2 Gb/s from a 1.8-V supply.

An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters (PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단)

  • Shon, Jin-Geun;Na, Chae-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

DC-link Voltage Ripple Compensation Method for Single Phase 3-level PWM Converters (단상 3-레벨 PWM 컨버터를 위한 중성점 전압 변동 보상 기법)

  • Lee, Hee-Myun;Lee, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.8-15
    • /
    • 2013
  • This paper proposes a DC-link voltage variation compensation method for a 3-level single phase converter for high-speed trains. Since 3-level NPC(Neutral Point Clamped) type converters have the split DC-link causing the inherent problem of voltage fluctuations in the upper and lower capacitors, reducing the voltage difference between the top and bottom capacitors is required. In this paper, compensation time proportional to the voltage difference is added to PWM switching time to solve the voltage variation. The compensation time is obtained by a PI controller. Simulation results demonstrate the validity of the proposed method.

Novel SRM Drive System Based on the DC-link Current Information (DC-link전류정보를 기반으로 한 새로운 SRM 구동시스템)

  • Kim Ju-Jin;Kim Seong-Gon;Lee Ju-Hwan;Kim Tae-Woong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.6-10
    • /
    • 2004
  • This paper newly proposes the SRM drive system based on DC-link current information, from which the phase currents can be estimated in accuracy and also they can be used in driving SRM instead of the phase currents. Comparing to the general drive system based on the phase current information, it is verified through the simulation(which are peformed by RMxprt and Simplorer) that the proposed SRM drive system has the good performance in dynamic and steady-state responses of the speed control. Using the DC-link current information, all of the multi-phase currents can be easily estimated in driving the SRM.

  • PDF

A study on the control of robotic manipulators with flexibility (탄성을 고려한 로보트 매니플레이터의 제어에 관한 연구)

  • Lee, Si-Bok;Jo, Hyeong-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.5 no.2
    • /
    • pp.23-32
    • /
    • 1988
  • A control system for improving the moving accuracy of robotic manipulators with elastic joints is devloped. The dynamics of manipulator system is splitted into two sub-dynamics; of arm-link and actuator rotor- link, which are coupled statically through joint torque. Two contorl loops are implemented respectively around both sub-dynamic systems. Computed torque algorithm with acceleration feedback is used for the arm-link control loop, and for the actuator rotor-link control loop PID algorithm is adopted. The resulting control system is tested through a series of computer simulation for a PUMA type manipulator, The reaults show good performance of the developed control system for wide range of joint stiffness and moving speed.

  • PDF

IPv6 Multicast Packet Transmission over IEEE 802.16 Networks (IEEE 802.16 망에서의 IPv6 멀티캐스트 패킷 전송 방법)

  • Jeong, Sang-Jin;Shin, Myung-Ki;Kim, Hyoung-Jun
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.235-236
    • /
    • 2006
  • IEEE 802.16 networks support mobile stations (MSs) to access broadband wireless networks while moving at a vehicular speed. However, IEEE 802.16 networks do not provide link layer native multicast capability because of point-to-multipoint connection characteristic. Due to this feature, it is not easy to adopt protocols or applications which need native link layer multicast capability. In order to solve the multicast support problem, we use the built-in LAN emulation feature of IEEE 802.16 which is based on Convergence Sublayer (CS). Our proposed operational procedures support not only the delivery of link local scope multicast packets, but also the delivery of non-link local scope multicast packets such as site local or global scope multicast packets. We also present the method of forming multicast Connection Identifier (CID) which is used to transport IP packets over IEEE 802.16 networks.

  • PDF

Performance Analysis by Secondary link Frame structure in UAV System (무인기 운용환경을 고려한 보조링크 프레임 구조설계에 따른 성능분석)

  • Yoon, Chang-Bae;Kim, Hoi-Jun;Hong, Su-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1115-1120
    • /
    • 2017
  • In this paper, we apply the LMMSE(: Linear Minimum Mean Square Error) algorithm to overcome the Doppler effect according to the UAV(: Unmanned Aerial Vehicle) velocity in multipath fading channel environment. Simulation results show that the performance difference depends on the pilot arrangement and pattern, and we confirmed that the frame structure proposed in this paper can provide a stable secondary link for high speed UAV system.

3-Phase Current Estimation of SRM Based on the DC-Link Current (직류링크 진류정보를 기반으로 한 SRM 3상전류 추정법)

  • Kim, Ju-Jin;Kim, Seong-Gon;Kim, Tae-Woong;Ahn, Jin-Woo;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.575-577
    • /
    • 2005
  • This paper proposes the SRM drive system based on DC-link current, from which the phase currents can be estimated in accuracy and also they can be used in driving SRM instead of the three-phase currents. In additional, the detecting circuit for DC-link current is also proposed for increasing the resolution and decreasing the off-set. Comparing to the general drive system based on the phase current, it is verified through the experiment that the proposed SRM drive system has the good performance in steady-state responses of the speed control. Using the DC-link current, all of the 3-phase currents can be easily estimated in driving the SRM.

  • PDF