• Title/Summary/Keyword: Linear siloxane

Search Result 13, Processing Time 0.022 seconds

Characteristics of Siloxane Concentrations in Bio Gas from Anaerobic Digestion of Food Wastewater (음식물류폐기물폐수의 혐기성 소화에서 바이오가스의 실록산 농도 특성)

  • Lee, Chae-Young;Lee, Se-Wook;Park, Su-Hee;Hur, Kwang-Beom;Kim, Hae-Ryong;Lee, Nam-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.4
    • /
    • pp.60-65
    • /
    • 2011
  • Siloxane is an organic silicon compound and is volatilized into the bio gas from anaerobic digestion. It causes failure of gas combustion engines using the bio gas. Siloxane emission characteristics should be identified to provide a proper siloxane control. This study focuses on characterizing siloxane emission in bio gas from an anaerobic digester of food wastewater operating from January to March. The concentrations of total average siloxane and cycle-siloxane D4 were detected to be 9.5 and $4.0mg\;siloxane/m^3$, respectively. The concentrations of cycle-siloxane and linear-siloxane were resulted in D4>D5>D6 and L4>L3>L5>L2, respectively. The total siloxane concentration was the lowest in January and the highest in March.

Epoxy-Based Siloxane/Silica Composites for Electronic Packaging by Composition and Molecular Structure of Siloxane, and Analysis of Changes in Properties (조성 및 실록산 분자 구조에 따른 전자 패키징용 에폭시 기반 실록산/실리카 복합체의 물성 변화 분석)

  • Junho Jang;Dong Jun Kang;Hyeon-Gyun Im
    • Journal of Powder Materials
    • /
    • v.30 no.4
    • /
    • pp.346-355
    • /
    • 2023
  • Epoxy-based composites find extensive application in electronic packaging due to their excellent processability and insulation properties. However, conventional epoxy-based polymers exhibit limitations in terms of thermal properties and insulation performance. In this study, we develop epoxy-based siloxane/silica composites that enhance the thermal, mechanical, and insulating properties of epoxy resins. This is achieved by employing a sol-gel-synthesized siloxane hybrid and spherical fused silica particles. Herein, we fabricate two types of epoxy-based siloxane/silica composites with different siloxane molecular structures (branched and linear siloxane networks) and investigate the changes in their properties for different compositions (with or without silica particles) and siloxane structures. The presence of a branched siloxane structure results in hardness and low insulating properties, while a linear siloxane structure yields softness and highly insulating properties. Both types of epoxy-based siloxane/silica composites exhibit high thermal stability and low thermal expansion. These properties are considerably improved by incorporating silica particles. We expect that our developed epoxy-based composites to hold significant potential as advanced electronic packaging materials, offering high-performance and robustness.

A Study on the Synthesis of Organic-Inorganic Hybrid Waterborne Polyurethane by Using Graft Type Siloxane Polyol (그래프트형 실록산 폴리올을 이용한 유-무기 하이브리드 수분산 폴리우레탄의 합성에 관한 연구)

  • Lim, Jae-Woo;Yim, Jin-Heong
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.569-574
    • /
    • 2009
  • Organic- inorganic hybrid waterborne polyurethane (PUD) is synthesized by using hybrid polyol consist of carbonate (PCD), ester (PCL), and siloxane (PDSBP) in order to enhance anti-scratch property of PUD film. The diameter of graft type PUD emulsion is bigger than that of linear type PUD due to the graft structure of hydrophobic siloxane chain. The glass transition temperature of linear type PUD increase and the decomposition temperature of linear type PUD decrease with the content of PCD polyol. While, the decomposition temperature of graft type PUD almost same with increasing PDSBP content. The anti-scratch property and pencil hardness of graft type PUD improves as adding PDSBP polyol in the hybrid polyol system. When 9 wt% of PDSBP polyol is mixed, PUD films shows excellent anti-scratch property (~3.3 N), and pencil hardness (> 9 H).

Syntheses and Properties of Copolymers of Tetramethyldisiloxane and 1,4-Bis(dimethylhydroxysilyl)benzene (Tetramethyldisiloxane-1,4-bis(dimethylhydroxysilyl)benzene 공중합체의 합성 및 특성)

  • Kim, Sun-ll;Yun, Young-Jae;Na, Jae-Woon
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.490-495
    • /
    • 1996
  • Low molecular weight linear chlorine terminated siloxanes (yields;71.2~86.5%) were prepared by reactions of cyclotri-, cyclotetra- and cyclopentasiloxane with dimethyldichlorosilane in the presence of pyridine N-oxide catalyst. The amine terminated siloxane oligomers were obtained in good yields(76.2~85.3%) by the reaction of linear chlorine terminated siloxanes with dimethylamine at $0^{\circ}C$. In this investigation, we have studied on the syntheses and properties of copolymers (yields;58.0~71.0%) obtained from the reaction of amine terminated siloxane oligomers with 1,4-bis(dimethylhydroxysilyl)benzene. The structures and properties of the copolymers were examined by FT-IR, $^1H$-NMR, TGA and DSC. Initial degradation temperatures($T_D{^i}$) of the polymer I and IV were confirmed as 476 and $485^{\circ}C$, respectively. The thermal stabilities of the polymers were found to be increased with increasing n of $(R_2SiO)_n$. The glass transition temperatures(Tg) of the polymers were increased with decreasing n of $(R_2SiO)_n$, and the lowest Tg revealed $-76^{\circ}C$ when n=5.

  • PDF

Comparative study on properties of commercial polyvinyl siloxane impression materials (시판 폴리비닐실록산 인상재의 물성에 관한 비교연구)

  • Kang, Jae-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.171-180
    • /
    • 2001
  • The purpose of this study was to compared with the properties of commercial polyvinyl siloxane impression materials on the Korean product and the other country one. The materials used in this study were 5 hydrophilic polvinyly siloxane impression materials of light body automixing type (Perfect-F, Handae Chemical, Korea; Examix, GC, Japan; Contrast, VOCO, Germany; Express, 3M, U.S.A; Extrude, Kerr, U.S.A.). Specimens of each impression material were fabricated from a mold with dimensions identical to that specified in ASTM D624-91 and were subjected to tensile lode at 500 mm/min until failure for tear strength. Properties of consistency, strain in compression, recovery from deformation, detail reproduction and linear dimensional change were tested according to the testing methods of the ISO specification no.4823(1992). From this study, the follow ing results were obtained 1. The tear strength values were high ET(3.4kN/m), EP(3.4kN/m), PF(3.0kN/m), CT(3.0kN/m), but the lowest was EM(2.2kN/m)(p<0.05). 2. In the consistency, CT(47 mm) had the highest value, followed by PF(42.1 mm), ET(41.2 mm), and EM(39.6 mm), EP(39.2 mm)(p<0.05). It means more flow that the consistency value is high. 3. The strain in compression values were high followed by EM(5.8%), PF(52%), CT(4.6%), ET(4.1%), EP(2.9%)(p<0.05). 4. In the recovery from deformation, ET(99.95%) and PF(99.90%) had the highest value, followed by EP(99.75%), EM(99.74%) without statistical signification, CT(99.64%) had the lowest value(p<0.05). 5. Detail reproduction reappeared to line $20{\mu}m$ all products. 6. The linear dimensional change was a little shrinked all products. and there were not statistical signification (p>0.05). All products were satisfied the ISO specification.

  • PDF

Thermal Properties of Interpenetrating Polymer Network Epoxy-silicone Compound

  • Cho, Young-Shin;Shim, Mi-Ja;Klm, Sang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.475-478
    • /
    • 1999
  • The thermal properties of epoxy resin/siloxane for the electrical insulation were investigated by using dynamic DSC run method. As the heating rate increased, the peak temperature on dynamic DSC curve increased. From the linear relation on the Kissinger plot the curing reaction activation energy and pre-exponential factor could be obtained. The curing activation energy from the straight line of the Kissinger plot was 46.72 kJ/mol.

  • PDF

DNA Separation Using Cellulose Derivatives and PEO by PDMS Microchip

  • Kang, Chung-mu;Back, Seung-Kwon;Song, In-gul;Choi, Byung-ok;Chang, Jun-keun;Cho, Keun-chang;Kim, Yong-seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.519-523
    • /
    • 2006
  • Poly(dimethyl siloxane) (PDMS) has been employed as a microchip material for DNA separation in microfluidic condition. Different sieving molecules such as cellulose derivatives having glucose building block (methyl cellulose (MC), hydroxyethyl cellulose (HEC), and hydroxypropyl methyl cellulose (HPMC)) and polyethylene oxide (PEO) having linear (ring-opened ethylene oxide) unit were used and their performance was compared in terms of separation efficiency and resolution. In general, PEO showed better separation performance than cellulose derivatives probably due to the nature of linear shape polymer conformation. It was possible to perform at least 15 consecutive running with 1.2% PEO at the electric field strength around 200 V/cm. Fast analysis of the standard $\Phi$X 174 RF DNA/Hae III (less than 130s) was obtained with the number of the theoretical plate around 250,000/m. Our PMDS microchip was applied to the measurement of CAG repeat number, which is related to male infertile disease.

Synthesis and Characterization of Waterborne Polyurethanes Based on Isophorone Diisocyanate and Mixed Polyols of Poly(tetramethylene glycol)/Polydimethylsiloxane Diol (이소포론 디이소시아네이트와 폴리(테트라메틸렌 글리콜)/폴리디메틸실록산 디올 혼합 폴리올을 사용한 수분산성 폴리우레탄의 합성과 특성 분석)

  • Lee, Ji Hye;Hong, Seongdon;Kim, Young Ho
    • Polymer(Korea)
    • /
    • v.37 no.2
    • /
    • pp.167-176
    • /
    • 2013
  • Linear and cross-linked waterborne polyurethanes (WPUs) based on isophorone diisocyanate and mixed diols of poly(tetramethylene glycol)/hydroxyethyl-terminated polydimethylsiloxane (PDMS-OH) were synthesized with dimethylol propionic acid as an anionic component, trimethylolpropane as a cross-linking agent, and butanediol as a chain extender and characterized. The hydrophobicity, $T_g$, stress-strain behaviors of the linear or cross-linked siloxane-containing WPU (WPU-Si) films with different PDMS content were analyzed by using water contact shape analyzer, energy dispersive spectrometer, dynamic mechanical analyzer, and universal testing machine. The results reveal that as the PDMS content increased, the hydrophobicity of WPU-Si films increased, $T_g$ moved to higher temperature, the breaking stress increased, and the breaking strain decreased.

Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans

  • Kontis, Panagiotis;Guth, Jan-Frederik;Schubert, Oliver;Keul, Christine
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.316-326
    • /
    • 2021
  • PURPOSE. Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. MATERIALS AND METHODS. A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17-P13, P17-P23, P17-P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). RESULTS. Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). CONCLUSION. Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.