• 제목/요약/키워드: Linear energy transfer

검색결과 162건 처리시간 0.023초

가동코일형 리니어 왕복 액추에이터의 동특성 (Dynamic Characteristics of Moving Coil Type Linear Oscillatory Actuator)

  • 장석명;정상섭;권철;박희창;문석준;박찬일;정태영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.180-187
    • /
    • 2000
  • A moving-coil-type linear oscillatory actuator(LOA) consists of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure. The LOA system was represented by the voltage equation of coil and the mechanical equation of motion. This set of equations was manipulated in state-space form. The EMF constant kE of equation parameters in state-space form can be obtained by using the induced voltage in armature coils at open circuit test. kE and other parameters provide the system matrices and transfer function for frequency response and dynamic simulation. Voltage source inverter-fed LOA is examined aiming to compare with results of simulation.

  • PDF

Calibration of HEPD on KOMPSAT-1 Using the KCCH Cyclotron

  • Shin, Young-Hoon;Rhee, Jin-Geun;Min, Kyoung-Wook;Lee, Chun-Sik;Lee, Ju-Hahn;Kwon, Young-Kwan;Kim, Jong-Chan;Ha, Jang-Ho;Park, Se-Hwan;Lee, Chang-Hack;Park, H.S.;Kim, Yong-Kyun;Chai, Jong-Seo;Kim, Yu-Seog;Lee, Hye-Young
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.208-213
    • /
    • 1999
  • Space Physics Sensor (SPS) on-board the KOMPSAT-1 consists of the High Energy Particle Detector (HEPD) and the Ionospheric Measurement Sensor (IMS). The HEPD is to characterize the low altitude high energy particle environment and the effects on the microelectronics due to these high energy Particles. It is composed of four sensors: Proton and Electron Spectrometer(PES), Linear Energy Transfer Spectrometer (LET), Total Dose Monitor (TDM), and Single Event Monitor(SEM). 35MeV proton beam from the medical KCCH cyclotron, at Korea Cancer Center Hospital in Seoul, is used to calibrate the PES. Primary proton beam of 35MeV scattered by polypropylene target is converted to various energy Protons according to the elastic collision kinematics. In this calibration, the threshold level of the proton in the PES can be determined and the energy ranges of PES channels are also calibrated.

  • PDF

A Design of Solar Proton Telescope for Next Generation Small Satellite

  • Sohn, Jongdae;Oh, Suyeon;Yi, Yu;Min, Kyoung-Wook;Lee, Dae-Young;Seon, Jongho
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권4호
    • /
    • pp.343-349
    • /
    • 2012
  • The solar proton telescope (SPT) is considered as one of the scientific instruments to be installed in instruments for the study of space storm (ISSS) which is determined for next generation small satellite-1 (NEXTSat-1). The SPT is the instrument that acquires the information on energetic particles, especially the energy and flux of proton, according to the solar activity in the space radiation environment. We performed the simulation to determine the specification of the SPT using geometry and tracking 4 (GEANT4). The simulation was performed in the range of 0.6-1,000 MeV considering that the proton, which is to be detected, corresponds to the high energy region according to the solar activity in the space radiation environment. By using aluminum as a blocking material and adjusting the energy detection range, we determined total 7 channels (0.6~5, 5~10, 10~20, 20~35, 35~52, 52~72, and >72 MeV) for the energy range of SPT. In the SPT, the proton energy was distinguished using linear energy transfer to compare with or discriminate from relativistic electron for the channels P1-P3 which are the range of less than 20 MeV, and above those channels, the energy was determined on the basis of whether silicon semiconductor detector (SSD) signal can pass or not. To determine the optimal channel, we performed the conceptual design of payload which uses the SSD. The designed SPT will improve the understanding on the capture and decline of solar energetic particles at the radiation belt by measuring the energetic proton.

목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석 (Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material)

  • 서정기;정수광;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권3호
    • /
    • pp.343-359
    • /
    • 2017
  • 건축물에서 사용되는 에너지를 줄이기 위하여 다양한 연구 및 정책이 진행되고 있으나 건축물에서 구조재 및 실내 외 마감재로 폭넓게 사용되는 목재의 열적 특성에 관한 연구는 미미한 실정이다. 이에 따라, 본 연구는 목질재료와 비 목질재료의 전열성능을 분석하기 위하여 목질재료가 주로 이용되는 주거용 건축물을 대상으로 열성능이 취약한(열교 발생) 부위를 선정하고, 각 부위별로 구조재와 마감재의 구성에 따라 총 16 Case에 대해 전열성능 분석을 실시하였다. 전열 해석 시뮬레이션 도구는 ISO 10211의 계산 방법을 따르는 Physibel Trisco를 이용하였다. 해석 부위의 모델링 역시 ISO 10211에서 제시된 기준에 의해 실시하였으며, 경계 온도 조건은 에너지절약설계기준에 따라 실내온도 $20^{\circ}C$, 실외온도 $-11.3^{\circ}C$(서울 기준)로 설정하였다. 구조는 콘크리트구조와 비 목질재료마감, 콘크리트구조와 목질재료마감 그리고 목구조에 목질재료마감의 경우에 따라 구분하였다. 부위는 벽체, 지붕, 층간바닥 및 최하층 바닥 등으로 구분하여 시뮬레이션을 진행하였다. 결과로서, 콘크리트구조의 경우 형상적 원인에 의해, 목구조의 경우 형상적인 원인에 재료적 원인이 더해져 다발적으로 열교가 발생함을 확인할 수 있었다. 추가적으로 콘크리트구조에서는 단열재의 불연속 부위에서 구조적인 열교가 발생하고 목구조에서는 구조적인 열교와 이질재료의 적용 부위에서 재료적 원인에 의한 열교가 발생하는 것을 확인할 수 있었다. 또한 콘크리트 구조에 목질 실내마감재를 적용하였을 경우에는 벽체의 선형 열관류율 값이 감소하는 것을 확인할 수 있었다.

방사면역치료를 위한 알파 방출 방사성 동위원소 생산 (Alpha-emitting Radioisotopes Production for Radioimmunotherapy)

  • 전권수
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.1-8
    • /
    • 2007
  • This review discusses the production of alpha-particle-emitting radionuclides in radioimmunotherapy. Radioimmunotherapy labeled with alpha-particle is expected to be very useful for the treatment of monocellular cancer (e.g. leukemia) and micrometastasis at an early stage, residual tumor remained in tissues after chemotherapy and tumor resection, due to the high linear energy transfer (LET) and the short path length in biological tissue of alpha particle. Despite of the expected effectiveness of alpha-particle in radioimmunotherapy, its clinical research has not been activated by the several reasons, shortage of a suitable a-particle development and a reliable radionuclide production and supply system, appropriate antibody and chelator development. Among them, the establishment of radionuclide development and supply system is a key factor to make an alpha-immunotherapy more popular in clinical trial. Alpha-emitter can be produced by several methods, natural radionuclides, reactor irradiation, cyclotron irradiation, generator system and elution. Due to the sharply increasing demand of $^{213}Bi$, which is a most promising radionuclide in radioimmunotherapy and now has been produced with reactor, the cyclotron production system should be developed urgently to meet the demand.

Time Series Simulation of Explosive Charges In Shallow Water Using Ray Approach

  • Hahn, Jooyoung;Lee, Seongwook;Na, Jungyul
    • The Journal of the Acoustical Society of Korea
    • /
    • 제22권3E호
    • /
    • pp.133-140
    • /
    • 2003
  • A time series simulation is presented by a ray approach for the simulating the received waveform of a broadband acoustical signals interacting with the ocean boundaries. The environment is assumed to be horizontally stratified, and the seafloor is described in terms of homogeneous fluid half-space. The ray approach includes the effects of reflection from the air-water, water-sediment interface and phase shifts due to boundaries interaction. To generate time series, we assume that the acoustic energy propagates from source to receiver along eigenrays and represent the action of the bottom on the incident wave by a linear filter and characterized in the frequency domain by the transfer function. As example application, the time series for an explosive source in a shallow water environment is calculated and analyzed in terms of acoustical process. good agreement with measured time series is demonstrated.

Basics of particle therapy I: physics

  • Park, Seo-Hyun;Kang, Jin-Oh
    • Radiation Oncology Journal
    • /
    • 제29권3호
    • /
    • pp.135-146
    • /
    • 2011
  • With the advance of modern radiation therapy technique, radiation dose conformation and dose distribution have improved dramatically. However, the progress does not completely fulfi ll the goal of cancer treatment such as improved local control or survival. The discordances with the clinical results are from the biophysical nature of photon, which is the main source of radiation therapy in current field, with the lower linear energy transfer to the target. As part of a natural progression, there recently has been a resurgence of interest in particle therapy, specifically using heavy charged particles, because these kinds of radiations serve theoretical advantages in both biological and physical aspects. The Korean government is to set up a heavy charged particle facility in Korea Institute of Radiological & Medical Sciences. This review introduces some of the elementary physics of the various particles for the sake of Korean radiation oncologists' interest.

The Control System Design of Nuclear Reactor Power by Kharitonov Method

  • Lee, Yoon-Joon;Na, Man-Gyun
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1208-1211
    • /
    • 2002
  • The robust controller for the nuclear reactor power control system is designed. The reactor model is described in the form of transfer function and the bound of each coefficient is determined to set up the linear interval system. By the Kharitonov and the edge theorem, a frequency based design template is made and applied to the determination of the controller. The controller designed by this method is simpler than that obtained by the H(equation omitted). Although the controller is designed with the basis of high power, it could be used even at low power.

  • PDF

Relationships between LET and RBE of lonizing Radiation in the induction of Somatic Mutations of Drosophila melanogaster

  • 유미애;정운혁;이원호
    • 한국환경성돌연변이발암원학회지
    • /
    • 제7권2호
    • /
    • pp.103-111
    • /
    • 1987
  • The effects of LET (linear energy transfer) of radiation on the induction of somatic chromosome mutations or gene mutations of Drosophila melanogaster were studied. For detecting somatic chromosome mutations and gene mutations, Drosophila wing spot system and eye-color spot system were used, respectively. The frequencies of somatic chromosome mutations or gene mutations induced after third instar larval treatment with 23 MeV neutrons, thermal neutrons, X-rays were examined. From these data, the RBE(relative biological effectiveness) values of 23 MeV neutrons relative to X-rays for induction of somatic chromosome mutations or gene mutations were calculated. The present results suggest that high LET radiations are efficient than X-ray in producing not only somatic chromosome mutations but also gene mutations.

  • PDF

Modeling for Vacuum Drying Characteristics of Onion Slices

  • Lee, Jun-Ho;Kim, Hui-Jeong
    • Food Science and Biotechnology
    • /
    • 제18권5호
    • /
    • pp.1293-1297
    • /
    • 2009
  • In this study, drying kinetics of onion slices was examined in a laboratory scale vacuum dryer at an air temperature in a range of $50-70^{\circ}C$. Moisture transfer from onion slices was described by applying the Fick's diffusion model, and the effective diffusivity was calculated. Temperature dependency of the effective diffusivity during drying process obeyed the Arrhenius relationship. Effective diffusivity increased with increasing temperature and the activation energy for the onion slices was estimated to be 16.92 kJ/mol. The experimental drying data were used to fit 9 drying models, and drying rate constants and coefficients of models tested were determined by non-linear regression analysis. Estimations by the page and Two-term exponential models were in good agreement with the experimental data obtained.