Experimental Study on the Stirling refrigerator for Cooling of Infrared Detector (적외선 센서 냉각용 스터링 냉동기의 실험적 연구)

  • Park, S.J.;Hong, Y.J.;Kim, H.B.;Koh, D.Y.;Kim, J.H.;Yu, B.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.172-176
    • /
    • 2001
  • A Stirling cryocooler is relatively compact, reliable, commercially available, and uses helium as a working fluid. The FPFD stirling cryocooler consists of two compressor pistons driven by linear motors which makes pressure waves and a pneumatically driven displacer piston with regenerator. A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). In order to evaluate the feasibility of using a linear motor driving cryocooler, prototype Stirling cryocooler with a nominal cooling capacity of 0.5W at 80K was designed, fabricated and tested. The prototype has achieved no load temperature of 51K and cooling power of 0.33W.

  • PDF

Efficient detectors for MIMO-OFDM systems under spatial correlation antenna arrays

  • Guerra, David William Marques;Fukuda, Rafael Masashi;Kobayashi, Ricardo Tadashi;Abrao, Taufik
    • ETRI Journal
    • /
    • v.40 no.5
    • /
    • pp.570-581
    • /
    • 2018
  • This work analyzes the performance of implementable detectors for the multiple-input multiple-output (MIMO) orthogonal frequency division multiplexing (OFDM) technique under specific and realistic operation system conditions, including antenna correlation and array configuration. A time-domain channel model was used to evaluate the system performance under realistic communication channel and system scenarios, including different channel correlation, modulation order, and antenna array configurations. Several MIMO-OFDM detectors were analyzed for the purpose of achieving high performance combined with high capacity systems and manageable computational complexity. Numerical Monte Carlo simulations demonstrate the channel selectivity effect, while the impact of the number of antennas, adoption of linear against heuristic-based detection schemes, and the spatial correlation effect under linear and planar antenna arrays are analyzed in the MIMO-OFDM context.

Design for Triple Band Patch Array Antenna with High Detection Ability

  • Kim, In-Hwan;Min, Kyeong-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.4
    • /
    • pp.214-223
    • /
    • 2013
  • This paper proposes a theoretical analysis of hidden device detection and a design of multiband circular polarization patch array antenna for non-linear junction detector system application. A good axial ratio of circular polarization patch antenna is realized by a new approach that employs inclined slots, two rectangular grooves and a truncated ground for the conventional antenna. A good axial ratio of the 1.5 dB lower is measured by having an asymmetric gap distance between the ground planes of the coplanar waveguide feeding structure. The common ground plane of the linear array has an optimum trapezoidal slot array to reduce the mutual coupling without increasing the distance between the radiators. The higher gain of about 1 dBi is realized by using the novel common ground structure. The measured return loss, gain, and axial ratio of the proposed single radiator, as well as the proposed array antennas, showed a good agreement with the simulated results.

Intersymbol Decorrelating Detector for Asynchronous CDMA Systems

  • Zhang Gaonan;Bi Guoan;Kot Alex Chichung
    • Journal of Communications and Networks
    • /
    • v.9 no.1
    • /
    • pp.28-33
    • /
    • 2007
  • Estimated channel information, especially multipath length and multipath channel of the desired user, is necessary for most previously reported linear blind multiuser detectors in code division multiple access (CDMA) systems. This paper presents a new blind intersymbol decorrelating detector in asynchronous CDMA systems, which uses the cross correlation matrix of the consecutive symbols. The proposed detector is attractive for its simplicity because no channel estimation is required except the synchronization of the desired user. Compared with other reported multiuser detectors, simulation results show that the proposed detector provides a good performance when the active users have significant intersymbol interference and the multipath length is short.

A CMOS RF Power Detector Using an AGC Loop (자동 이득제어 루프를 이용한 CMOS RF 전력 검출기)

  • Lee, Dongyeol;Kim, Jongsun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.101-106
    • /
    • 2014
  • This paper presents a wide dynamic range radio-frequency (RF) root-mean-square (RMS) power detector using an automatic gain control (AGC) loop. The AGC loop consists of a variable gain amplifier (VGA), RMS conversion block and gain control block. The VGA exploits dB-linear gain characteristic of the cascade VGA. The proposed circuit utilizes full-wave squaring and generates a DC voltage proportional to the RMS of an input RF signal. The proposed RMS power detector operates from 500MHz to 5GHz. The detecting input signal range is from 0 dBm to -70 dBm or more with a conversion gain of -4.53 mV/dBm. The proposed RMS power detector is designed in a 65-nm 1.2-V CMOS process, and dissipates a power of 5 mW. The total active area is $0.0097mm^2$.

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

Design and Implementation of Broadband Power Detector for Six-port Direct Conversion Receiver (Six-port 직접 변환 수신을 위한 광대역 Power detector 설계 제작)

  • Lee, Yong-Ju;Kim, Yeong-Wan;Park, Dong-Cheol
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • The broadband power detector for power amplitude envelope detection of the direct-conversion Six-port output signal was designed and implemented in this paper. The power detector should be linearly operated to produce the linear amplitude and phase signal for input RF signals in required broadband frequency range. The power detector should be designed under conditions of matching circuit with low VSWR, which protect unbalanced phase signal from reflection signal due to mismatch between the output port of a six-port and the input port of a power detector. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with multiple LC matching circuits and isolator, respectively, were analyzed in viewpoints of the utilization as a power detector of direct conversion Six-port. The dynamic range of designed power detectors were also measured and rvaluated as a power detector of Six-port circuit.

  • PDF

Design of the Linear Compressor Stirling Cryocooler (Linear compressor 스터링 냉동기 설계에 관한 연구)

  • 박성제;고득용;홍용주;김효봉
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.81-84
    • /
    • 2000
  • This paper presents operating process and design method on the linear compressor Stirling cryocooler for cooling infrared detector. The free piston-type Stirling cryocooler, which applies 1) the Stirling cycle for refrigeration, 2) linear motors for driving, 3) flexure bearings for support systems, and 4) fine gap for clearance seals, is the most suitable design for a mechanical cryocooler utilized in a night vision environment.

  • PDF