• Title/Summary/Keyword: Linear Cell

Search Result 858, Processing Time 0.031 seconds

The Selective Inhibitory Activity of a Fusaricidin Derivative on a Bloom-Forming Cyanobacterium, Microcystis sp.

  • Ko, So-Ra;Lee, Young-Ki;Srivastava, Ankita;Park, Seung-Hwan;Ahn, Chi-Yong;Oh, Hee-Mock
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.1
    • /
    • pp.59-65
    • /
    • 2019
  • Fusaricidin analogs, produced by Paenibacillus polymyxa, were tested for selective control of a major bloom-forming cyanobacterium, Microcystis sp. Fusaricidin (A and B mixtures) and four analogs were isolated from P. polymyxa E681 and investigated for their inhibition of cyanobacterial cell growth. Among the four fusaricidin analogs, fraction 915 Da (designated as Fus901) showed growth inhibition activity for Microcystis aeruginosa but not for Anabaena variabilis and Scenedesmus acutus. Microcystin concentration decreased up to 70% and its content per cell also decreased over 50% after 3 days. Fusaricidin exhibited growth inhibition against Gram-positive bacteria but Fus901 did not. Molecular weights of fusaricidin A and B were 883 Da and 897 Da, whereas that of Fus901 was 915 Da. Structure analysis by a ring-opening method revealed a linear form for Fus901. Expression of the pod gene related to oxidative stress was increased 2.1-fold by Fus901 and that of mcyD decreased up to 40%. These results indicate that Fus901 exerts oxidative stress against M. aeruginosa. Thus, Fus901 can be used as a selective cyanobactericide without disturbing the ecological system and could help in decreasing the microcystin concentration.

Non-contact Stress Measurement in Steel Member of PSC Box Bridge Using Raman Spectroscopy (라만 형광 분광법을 이용한 PSC 박스교 인장케이블 응력측정방법 연구)

  • Kim, Jongwoo;Kim, Namgyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.130-134
    • /
    • 2019
  • In this paper, a laser-based non-contact load cell is newly developed for measuring forces in prestressed concrete tendons. First, alumina particles have been sprayed onto an empty load cell which has no strain gauges on it, and the layer has been used as a passive stress sensor. Then, the spectral shifts in fluorescence spectroscopy have been measured using a laser-based spectroscopic system under various force levels, and it has been found that the relation of applied force and spectral shift is linear in a lab-scale test. To validate the field applicability of the customized load cell, a full-scale prestressed concrete specimen has been constructed in a yard. During the field test, it was, however, found that the coating surface has irregular stress distribution. Therefore, the location of a probe has to be fixed onto the customized load cell for using the coating layer as a passive stress sensor. So, a prototype customized load cell has been manufactured, which consists of a probe mount on its casing. Then, by performing lab-scale uniaxial compression tests with the prototype load cell, a linear relation between compression stress and spectrum shift at a specific point where laser light had been illuminated has been detected. Thus, it has a high possibility to use the prototype load cell as a force sensor of prestressed concrete tendons.

Analysis for Performance Deviation of Individual Cells in a Multi-Cell Test System for Rapid-Screening of Electrode Materials in PEMFCs (고분자전해질 연료전지용 전극물질의 빠른 스크리닝을 위한 멀티셀 테스트 시스템에서 개별셀의 성능편차에 대한 분석)

  • Zhang, Yan;Lee, Ji-Jung;Park, Gyung-Se;Lee, Hong-Ki;Shim, Joong-Pyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.842-851
    • /
    • 2011
  • A multi-cell test system with 25 independent cells is used to test different electrode materials simultaneously for polymer electrolyte membrane fuel cells (PEMFCs). Twenty-five segmented membrane electrode assemblies (MEAs) having the same or different Pt-loading are prepared to analyze the performance deviation of cells in the multi-cell test system. Improvements in the multi-cell test system are made by ensuring that the system performs voltage sensing for the cells individually and inserting optimum gaskets between the MEAs and the graphite plates. The cell performances are improved and their deviations are significantly decreased by these modifications. The performance deviations changed according to various cell configurations because the operating conditions of the cells, such as the gas flow and concentration, differed. This cell system can be used to test multiple electrodes simultaneously because it shows relatively uniform performance under the same conditions as well as linear correlation with various catalyst loadings.

Analysis for Insulating Degradation Characteristics with Aging Time for Oil-filled Transformers and/or Correlation between using Linear Regression Method (유입식 변압기의 열화시간에 따른 절연 열화특성 및 선형회귀법을 이용한 상관관계 분석)

  • Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.693-699
    • /
    • 2010
  • General transformer's life is known as paper insulation' life. If a transformer is degraded by these aging factors, it is known that electrical, mechanical and chemical characteristics for transformer's oil-paper are changed. When the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. The paper breakdown is accompanied by an increase in the content of furanic compounds within the dielectric liquid. In this paper it is aimed at analysis on correlation between aging characteristics for insulating diagnosis of thermally aged paper. For investigating the accelerated aging process of oil-paper samples accelerating aging cell was manufactured for estimating variation of paper insulation during 500 hours at $140^{\circ}C$ temperature. To derive the results, it was performed analysis such as tensile strength(TS), depolymerization(DP), dielectric strength(DS), relative permittivity, water content(WC) and furan compound(FC) for aged paper. Also for analyzing correlation between insulating degradation characteristics, we used linear regression method. As as results of linear regression analysis, there was a close correlation between TS and DP. WC, FC. But dielectric strength was a weak correlation with aging time.

Analytical and multicoupled methods for optimal steady-state thermoelectric solutions

  • Moreno-Navarro, Pablo;Perez-Aparicio, Jose L.;Gomez-Hernandez, J.J.
    • Coupled systems mechanics
    • /
    • v.11 no.2
    • /
    • pp.151-166
    • /
    • 2022
  • Peltier cells have low efficiency, but they are becoming attractive alternatives for affordable and environmentally clean cooling. In this line, the current article develops closed-form and semianalytical solutions to improve the temperature distribution of Bi2Te3 thermoelements. From the distribution, the main objective of the current work-the optimal electric intensity to maximize cooling-is inferred. The general one-dimensional differential coupled equation is integrated for linear and quadratic geometry of thermoelements, under temperature constant properties. For a general shape, a piece-wise solution based on heat flux continuity among virtual layers gives accurate analytical solutions. For variable properties, another piece-wise solution is developed but solved iteratively. Taking advantage of the formulae, the optimal intensity is directly derived with a minimal computational cost; its value will be of utility for more advanced designs. Finally, a parametric study including straight, two linear, barrel, hourglass and vase geometries is presented, drawing conclusions on how the shape of the thermoelement affects the coupled phenomena. A specially developed coupled and non-linear finite element research code is run taking into account all the materials of the cell and using symmetries and repetitions. These accurate results are used to validate the analytical ones.

Effects of Dietary Probiotic Complex on Growth Performance, Blood Immunological Parameters and Fecal Malodor Gas Emission in Growing Pigs (복합 생균제 첨가가 육성돈의 생산성, 면역관련 혈액학적 지표 및 분내 유해가스 발생에 미치는 영향)

  • Jang, H.D.;Kim, H.J.;Cho, J.H.;Chen, Y.G.;Yoo, J.S.;Kim, I.H.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.501-508
    • /
    • 2007
  • This study was conducted to evaluate effect of probiotic complex(Lactobacillus acidophilus, Bacillus subtilis and Aspergillus oryzae) on growth performance, blood immunological parameters and fecal malodor gas emissions in growing pigs. Forty-eight pigs[(Landrace × Yorkshire) × Duroc, 25.31±1.29kg average initial body weight] were used in 35d growth trial. Dietary treatments included CON(basal diet), PC1(basal diet + 0.1% probiotic complex) and PC2(basal diet + 0.2% probiotic complex). From d 0 to 20, ADFI was significantly increased in PC1 and PC2 compared to CON(Linear effect, P=0.013). From d 21 to 35, ADFI was increased in PC1 compared to CON(Quadratic effect, P=0.024). For the whole period, ADFI was increased PC2 and PC1 compared to CON(Linear effect, P=0.009, Quadratic effect, P=0.004). For the whole period, ADG was increased in PC1 compared to CON(Quadratic effect, P=0.017). G/F was not affected by treatments. Dry matter digestibility in PC2 was higher than PC1 and CON(Linear effect, P=0.001). Nitrogen digestibility was significantly higher in PC2 and PC1 than CON(Linear effect, P=0.005). In blood immunological parameters, Total protein, IgG, red blood cell(RBC) and white blood cell(WBC) were increased in PC2 compared to PC1 and CON(Linear effect, P<0.001, Quadratic effect, P<0.001). In fecal malodor gas emission, ammonia and acetic acid were significantly reduced in PC2 compared to CON(Linear effect, P<0.02). Hydrogen sulfide was significantly reduced in PC2 compared to CON(Linear effect, P=0.0002, Quadratic effect, P=0.018). However, total mercaptans was not affected by treatments. Water content of feces was not significantly different among the treatments. In conclusion, 0.2 % probiotic complex improved ADFI, apparent dry matter and nitrogen digestibility, Total protein, IgG, RBC and WBC. Also, it decreased ammonia, acetic acid and hydrogen sulfide emissions in growing pigs.

Shaft resistance of bored cast-in-place concrete piles in oil sand - Case study

  • Barr, L.;Wong, R.C.K.
    • Geomechanics and Engineering
    • /
    • v.5 no.2
    • /
    • pp.119-142
    • /
    • 2013
  • Pile load tests using Osterberg cells (O-cell) were conducted on cast-in-place concrete piles founded in oil sand fill and in situ oil sand at an industrial plant site in Fort McMurray, Alberta, Canada. Interpreted pile test results show that very high pile shaft resistance (with the Bjerrum-Burland or Beta coefficient of 2.5-4.5) against oil sand could be mobilized at small relative displacements of 2-3% of shaft diameter. Finite element simulations based on linear elastic and elasto-plastic models for oil sand materials were used to analyze the pile load test measurements. Two constitutive models yield comparable top-down load versus pile head displacement curves, but very different behaviour in mobilization of pile shaft and end bearing resistances. The elasto-plastic model produces more consistent matching in both pile shaft and end bearing resistances whereas the linear elastic under- and over-predicts the shaft and end bearing resistances, respectively. The mobilization of high shaft resistance in oil sand under pile load is attributed to the very dense and interlocked structure of oil sand which results in high matrix stiffness, high friction angle, and high shear dilation.

Numerical characterizations of a piezoelectric micromotor using topology optimization design

  • Olyaie, M. Sadeghbeigi;Razfar, M.R.
    • Smart Structures and Systems
    • /
    • v.11 no.3
    • /
    • pp.241-259
    • /
    • 2013
  • This paper presents the optimum load-speed diagram evaluation for a linear micromotor, including multitude cantilever piezoelectric bimorphs, briefly. Each microbeam in the mechanism can be actuated in both axial and flexural modes simultaneously. For this design, we consider quasi-static and linear conditions, and a relatively new numerical method called the smoothed finite element method (S-FEM) is introduced here. For this purpose, after finding an optimum volume fraction for piezoelectric layers through a standard numerical method such as quadratic finite element method, the relevant load-speed curves of the optimized micromotor are examined and compared by deterministic topology optimization (DTO) design. In this regard, to avoid the overly stiff behavior in FEM modeling, a numerical method known as the cell-based smoothed finite element method (CS-FEM, as a branch of S-FEM) is applied for our DTO problem. The topology optimization procedure to find the optimal design is implemented using a solid isotropic material with a penalization (SIMP) approximation and a method of moving asymptotes (MMA) optimizer. Because of the higher efficiency and accuracy of S-FEMs with respect to standard FEMs, the main micromotor characteristics of our final DTO design using a softer CS-FEM are substantially improved.

Accurate Representation of Light-intensity Information by the Neural Activities of Independently Firing Retinal Ganglion Cells

  • Ryu, Sang-Baek;Ye, Jang-Hee;Kim, Chi-Hyun;Goo, Yong-Sook;Kim, Kyung-Hwan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.3
    • /
    • pp.221-227
    • /
    • 2009
  • For successful restoration of visual function by a visual neural prosthesis such as retinal implant, electrical stimulation should evoke neural responses so that the informat.ion on visual input is properly represented. A stimulation strategy, which means a method for generating stimulation waveforms based on visual input, should be developed for this purpose. We proposed to use the decoding of visual input from retinal ganglion cell (RGC) responses for the evaluation of stimulus encoding strategy. This is based on the assumption that reliable encoding of visual information in RGC responses is required to enable successful visual perception. The main purpose of this study was to determine the influence of inter-dependence among stimulated RGCs activities on decoding accuracy. Light intensity variations were decoded from multiunit RGC spike trains using an optimal linear filter. More accurate decoding was possible when different types of RGCs were used together as input. Decoding accuracy was enhanced with independently firing RGCs compared to synchronously firing RGCs. This implies that stimulation of independently-firing RGCs and RGCs of different types may be beneficial for visual function restoration by retinal prosthesis.

A Study on Reducing the Corrosion of Steel Rebar Embedded in Concrete using Various Materials of Coating (다양한 코팅재를 이용한 콘크리트 중 철근의 부식 억제에 관한 연구)

  • Song, Il-Hyun;Lee, Yong-Soo;Ryou, Jae-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.179-180
    • /
    • 2010
  • The literature of present study was performed with content of chloride by total 6 level. After casting, and then, to measure the results of corrosion in a quick time used accelerated method of corrosion during 20 weeks. Both Galvanic and Half-cell for 20 weeks was used to model the initial time to corrosion, and then current of corrosion was measured by using Linear polarization at the end of cycling. The processing of steel used in concrete is same way as the case of mortar and also the initial time of corrosion was measured.

  • PDF