• Title/Summary/Keyword: Line-to-ground

Search Result 1,462, Processing Time 0.033 seconds

A Development of Ultra-compact Passive Components Employing Periodic Ground Structure for Silicon RFIC (주기적 접지구조를 이용한 실리콘 RFIC용 초소형 수동소자의 개발)

  • Yun, Young;Kim, Se-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.562-568
    • /
    • 2009
  • In this paper, using the periodic ground structure (PGS), highly miniaturized branch-line coupler and impedance transformer were realized on Si radio frequency integrated circuit (RFIC). The branch-line couple exhibited good RF performance from 41.75 to 50 GHz, and its size was $0.46{\times}0.55mm^2$, which is 37 % of conventional one. The impedance transformer exhibited good RF performance from 1 to 40GHz, and its size was $0.01mm^2$, which is 6.99 % of conventional one.

An EMTDC Analysis for Ground Faults with a Superconducting Fault Current Limiter (초전도 한류기를 포함한 계통의 지락사고에 대한 EMTDC 해석)

  • Choe, Hyo-Sang;Hyeon, Ok-Bae;Go, Tae-Guk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.161-166
    • /
    • 1999
  • We have performed an EMTDC simulation for the current limiting effects of a superconducting fault current limiter (SFCL). The fault currents in the 154 kV transmission line between the arbitrary S1 and S2 substations increased up to 39 kA during the single and double line-to-ground faults, respectively. The SFCL in the transmission line is sufficient.

  • PDF

Analysis of the Influence of Ground Effect on the Aerodynamic Performance of a Wing Using Lifting-Line Method (양력선 방법을 이용한 지면효과가 날개의 공력성능에 미치는 영향 분석)

  • Lee, Chang Ho;Kang, Hyung Min;Kim, Cheolwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.4
    • /
    • pp.298-304
    • /
    • 2014
  • The lifting-line method based on Weissinger's method is extended to be able to analyze the ground effect. The method is applied to predict the variation of aerodynamic performance due to ground effect for the elliptic wing with aspect ratio of 10 and the wing of human powered aircraft. While the vortex strength of the wing increases slightly, the downwash decreases significantly as the wing approaches to the ground. For the wing of human powered aircraft, the increment of lift at the height of 2m is 5% than the lift outside the influence of ground effect. The decrease of induced drag at the height of wing span is 10% and at the height of 2m is 55% than that out of ground effect.

Reduction Effect of Railroad Vibration by Utilizing Waste Tires (폐타이어의 철도진동 저감효과에 대한 실험적 연구)

  • Kim, Jin-Man;Lee, Kwang-Wu;Cho, Sam-Deok;Oh, Se-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.1
    • /
    • pp.31-40
    • /
    • 2006
  • This paper describes the results of a series of field experiments which are carried out to assess the reduction effect of railroad vibration by utilizing waste tires. The ground vibration due to train service is measured in Honam Railroad line and Kyongbu Railroad line to assess the ground vibration with the domestic railroad line and train type before field model test. From the results of these tests, frequency on train service is presented from 5Hz to 100Hz and a range of excellence frequency is presented to be about from 20Hz to 40Hz in the domestic railroad line. Also, plate bearing tests are conducted to evaluate the variation of bearing capacity with different thickness of the waste tire layer and the fill layer. Finally, field model test is performed by using tire chips ($5cm{\times}5cm$ in size) as a reduction material of railroad vibration. The reduction effect of railroad vibration by utilizing waste tires increases with increasing the thickness of the waste tire layer and the frequency of the vibration source. The results of this experimental study was shown that the waste tire can be used for reduction of the railroad vibration.

Correlation of Soil Physical Properties and Growth of Turfgrass on the Ground of Olympic-mainstadium (Olympic 주경기장 지반 상토층의 토양 물리성과 잔디 생육의 상관관계)

  • 김인철;주영규;이정호
    • Asian Journal of Turfgrass Science
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2002
  • This study was conducted to analyze the correlation of soil physical properties and growth of turfgrass on the ground of Olympic-mainstadium. Soil hardness and turf visual quality were measured at 77 plots (10m x 10m divided each) independently and analyzed correlation later. Physicochemical properties of the topsoil analyzed from three typical levels of the severely, moderately, slightly compacted areas. The ground showed high hardness at the center circle and the goal line, but low at the end line areas. On the contrary, visual quality rate of turfgrass was low at the center circle and the goal line, but high at the end line areas. The correlation was shown a significant negative value on soil hardness between turf visual quality Soil hardness seems to be accelerated by the improper soil texture of sandy loam which contained a large amount of finer particle of silt (10.7%) and clay (11.1%) which values exceeded for USGA (United State Golf Association) recommendation. Deterioration of turf quality resulted initially from improper construction and followed by high soil compaction with continuous uses of the ground without proper maintenance. To perform the international quality of the turf ground, the initial construction procedures should be followed by standard specifications of sport ground.

The Effects of Common Ground according to Fault Conditions in The Underground Transmission and Distribution System (고장조건에 따른 지중송배전계통에서 공통접지의 영향 분석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.285-287
    • /
    • 2007
  • This paper describes that the effect on the other system is generated by the single line to ground fault of the underground transmission systems and distribution systems established the common ground in trefoil. Each system is modeled by EMTP/ATPDraw and the system carry out simulations according to the various values of common ground to analyse. In this study, the result of analysis based on simulation suggests protection method and ground system of each system.

  • PDF

Design of Dumbbell-type CPW Transmission Lines in Optoelectric Circuit PCBs for Improving Return Loss (광전회로 PCB에서 반사특성 개선을 위한 덤벨 형태의 CPW 전송선 설계)

  • Lee, Jong-Hyuk;Kim, Hwe-Kyung;Im, Young-Min;Jang, Seung-Ho;Kim, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4A
    • /
    • pp.408-416
    • /
    • 2010
  • A dumbbell-type CPW transmission-line structure has been proposed to improve the return loss of the transmission line between a driver IC and flip-chip-bonding VCSEL(Vertical Cavity Surface Emitting Laser) in a hybrid opto-electric circuit board(OECB). The proposed structure used a pair of dummy ground solder balls on the ground lines for flip-chip bonding of the VCSEL and designed the dumbbell-type CPW transmission line to improve reflection characteristics. The simulated results revealed that the return loss of the dumbbell-type CPW transmission line was 13-dB lower than the conventional CPW transmission line. A 4-dB improvement in the return loss was obtained using the dummy ground solder balls on the ground lines. The variation rate of the reflection characteristic with the variation of terminal impedances of the transmission line (at the output terminal of the driver IC and the input terminal of the VCSEL) is about ${\pm}2.5\;dB$.

Minimizing Design of the Schiffman Phase Shifter Using the Defected Ground Structure (결함접지면을 이용한 쉬프만 위상 천이기의 소형화)

  • Kim, Gi-Rae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.9
    • /
    • pp.1745-1752
    • /
    • 2009
  • This Paper represents a new method, which uses defected ground structure (DGS) on the ground planes of microstrip lines, to reduce the size of the Schiffman phase shifter. DGS on the microstrip line shows an increased slow-wave effect due to the additional equivalent L and C components. So the electrical length of transmission line with DGS is longer than that of standard transmission line for the same physical length. Then, the length of transmission line with DGS can be shortened in order to maintain the original electrical length to be same. The performances of reduced phase shifter with DGS are quite similar to the ones of original Schiffman phase shifters. We can reduce the size about 15% using the DGS in original Schiffman phase shifter.

Study on the Line Simplification Method based on Turning Function for updating Digital Map (수치지도 갱신을 위한 선회함수 기반의 선형 단순화 기법 연구)

  • Park, Woo-Jin;Park, Seung-Yong;Woo, Ho-Seok;Yu, Ki-Yun
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2009.04a
    • /
    • pp.15-17
    • /
    • 2009
  • The line simplification method based on the turning function is studied in this paper for conversion of ground plan data to geospatial data to update the digital map. This method eliminate vertices effectively by estimating the length and the angle between the vertices based on the turning function which is useful to express the shape of linear feature. As the result, this method shows high shape similarity, high elimination rate of vertices and 100% of satisfaction degree to the drawing rules. Thus this line simplification method is judged to be effective in updating the digital map with ground plans.

  • PDF

A Study on the Characteristic of Variable Impedance Line using DGS (DGS를 이용한 가변 임피던스 선로 특성에 관한 연구)

  • Kim Young-Ju;Joung Myoung-Sub;Park Jun-Seok;Cho Hong-Goo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.1
    • /
    • pp.35-40
    • /
    • 2005
  • In this paper, we designed and fabricated the variable impedance line by using the DGS(Defected Ground Structure) which is useful in mounting the external lumped elements. Also we used a varactor diode as Control device stuff at the proposed variable impedance line. We are able to change the impedance of transmission line as varied the capacitance of varactor diode by adjusting DC bias. The impedance variation of the proposed DGS line is about maximum 70 Ω. We will study about the application of DAM(Direct antenna modulation) in the future work.