An Algorithm of fault Location Technique for Long Transmission Line (송전선로의 고장점 표정 알고리즘)

  • Park, C.W.;Kim, S.R.;Shin, M.C.;Nam, S.B.;Lee, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.145-147
    • /
    • 2002
  • In this paper, the improved fault locating method using distributed parameter which calculating the reduced voltage and current according to the ground capacitance in long transmission line was proposed. For the purpose of the fault locating algorithm non influenced source impedance, the loop method was used in the system modeling analysis. To enhance the fault locating, zero sequence of the fault current which is variable according to ground capacitance was not used but positive and negative sequence. System model was simulated using EMTP software. To verify the accuracy of proposed method, in different cases 64 sampled data per cycle was used and 160km and 300km long transmission line has fault resistance $0{\Omega}\;and\;100{\Omega}$ respectively was compared.

  • PDF

Performance Analysis of Hybrid Type HVDC Circuit Breakers in Voltage Source Converter based HVDC System (전압형 HVDC 시스템 적용을 고려한 Hybrid Type HVDC 차단기의 동작 특성 분석)

  • Khan, Umer Amir;Lee, Jong-Gun;Lim, Sung-Woo;Lee, Ho-Yun;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.153-154
    • /
    • 2015
  • Voltage Source Converter HVDC (VSC-HVDC) are a better alternative than conventional thyristor based HVDC systems. Unfortunately, VSC-HVDC's full potential cannot be utilized up till now due to absence of suitable HVDC protection. Recently, hybrid HVDC circuit breakers (HDCCB) have been developed and successfully lab tested. However, their application and feasibility in VSC-HVDC needs to be investigated. In this research paper we have modelled an existing HDCCB and evaluated its impact on fault reduction and interruption in VSC-HVDC systems. The HDCCB was applied in Korean Jeju-Haenam VSC-HVDC system model and its impact was analyzed for HVDC line-to-ground and line-to-line faults. HDCCB successfully interrupted the fault current and prevented the damages to costly IGBTs and converter transformers.

  • PDF

Parallel Transmission Lines Fault location Algorithm for single line-to-ground fault (평형 2회선 송전 계통의 1선지락시 고장점 표정 알고리즘)

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.317-319
    • /
    • 2006
  • This paper proposes a fault location algorithm for two-parallel transmission line in the case of single line-to-ground fault Proposed algorithm is using voltage and current measured in the sending-end. The fault distance is simply determined by solving a second order polynomial equation due to the direct circuit analysis. The simulations by PSCAD/EMTDC have demonstrated the accuracy and effectiveness of the proposed algorithm.

  • PDF

Power Hardware-in-the-Loop (PHIL) Simulation Testbed for Testing Electrical Interactions Between Power Converter and Fault Conditions of DC Microgrid (컨버터와 DC 마이크로그리드 사고 상황의 상호작용을 검증하기 위한 실시간 전력 시뮬레이션 테스트 베드)

  • Heo, Kyung-Wook;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.150-157
    • /
    • 2021
  • Nowadays, a DC microgrid that can link various distributed power sources is gaining much attention. Accordingly, research on fault situations, such as line-to-line and line-to-ground faults of the DC microgrid, has been conducted to improve grid reliability. However, the blackout of an AC system and the oscillation of a DC bus voltage have not been reported or have not been sufficiently verified by previous research. In this study, a 20 kW DC microgrid testbed using a power HIL simulation technique is proposed. This testbed can simulate various fault conditions without any additional grid facilities and dangerous experiments. It includes the blackout of the DC microgrid caused by the AC utility grid's blackout, a drastic load increment, and the DC bus voltage oscillation caused by the LCL filter of the voltage source converter. The effectiveness of the proposed testbed is verified by using Opal-RT's OP5707 real-time simulator with a 3 kW prototype three-port dual-active-bridge converter.

Estimation of Voltage Swell Frequency Caused by Asymmetrical Faults

  • Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1376-1385
    • /
    • 2017
  • This paper proposes a method for estimating the expected frequency of voltage swells caused by asymmetrical faults in a power system. Although voltage swell is less common than voltage sag, repeated swells can have severe destructive impact on sensitive equipment. It is essential to understand system performance related to voltage swells for finding optimal countermeasures. An expected swell frequency at a sensitive load terminal can be estimated based on the concept of an area of vulnerability (AOV) and long-term system fault data. This paper describes an effective method for calculating an AOV to voltage swells. Interval estimation for an expected swell frequency is also presented for effective understanding of system performance. The proposed method provides long-term performance evaluation of the frequency and degree of voltage swell occurrences.

Analysis of Pull-in-Voltage and Figure-of-Merit of Capacitive MEMS Switch

  • Saha, Rajesh;Maity, Santanu;Devi, Ngasepam Monica;Bhunia, Chandan Tilak
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.3
    • /
    • pp.129-133
    • /
    • 2016
  • Theoretical and graphical analysis of pull-in-voltage and figure of merit for a fixed-fixed capacitive Micro Electromechanical Systems (MEMS) switch is presented in this paper. MEMS switch consists of a thin electrode called bridge suspended over a central line and both ends of the bridge are fixed at the ground planes of a coplanar waveguide (CPW) structure. A thin layer of dielectric material is deposited between the bridge and centre conductor to avoid stiction and provide low impedance path between the electrodes. When an actuation voltage is applied between the electrodes, the metal bridge acquires pull in effect as it crosses one third of distance between them. In this study, we describe behavior of pull-in voltage and figure of merit (or capacitance ratio) of capacitive MEMS switch for five different dielectric materials. The effects of dielectric thicknesses are also considered to calculate the values of pull-in-voltage and capacitance ratio. This work shows that a reduced pull-in-voltage with increase in capacitance ratio can be achieved by using dielectric material of high dielectric constant above the central line of CPW.

A Study on Electrified Railway Traction System Impedance Calculation (전철선로 임피던스계산에 관한 연구)

  • Lee, Chon-Bae;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1407-1412
    • /
    • 2004
  • Impedance calculations of electric railway traction systems is essential to define characteristics and to design it. The self impedance is defined voltage drop rate per unit length, the mutual impedance is represented as a voltage induced to transmission line from transmission line. The self and the mutual impedance are influenced by ground return currents. The earth is considered as a semi-infinitely extended non-ideal conductor. The current of transmission line produces earth current induced magnetically and it flow through a path having minimum impedance. Carson proposed the impedance calculation formula using wave equations and magnetic field equations. Though the formula have an improper equation, that is still used as a standard impedance calculation method. This paper introduced an impedance calculation method that the complex depth of earth return method assumes that the current in conductor returns through an imagined earth depth path located directly under original conductor at a depth of. In this paper, we showed that this proposed method has a closed form and is easier than Carson's.

  • PDF

Dynamic Voltage Restorer Control Using $H_{\infty}$ Algorithm ($H_{\infty}$ 알고리즘을 이용한 Dynamic Voltage Restorer의 제어)

  • Chun, Yeong-Han;Kim, Ji-Won;Jeon, Jin-Hong
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.12
    • /
    • pp.561-565
    • /
    • 2001
  • Recent trend of increasing automated factories needs supply of high quality power from the utilities. Among the items of the power quality, voltage sag can be compensated by Dynamic Voltage Restorer(DVR). The key feature of the DVR is high response with less transient period to recover from the voltage sag due to the lightning or line-to-ground faults. In this paper we report that $H_{\infty}$ controller is very promising for the practical application to the controller of DVR. Experimental results shown in this paper was obtained by applying the control algorithm to 20 kVA DVR system. The experimental set consists of IGBT-based three phase inverter and the TMS320C32-60 DSP used for main processor of the control board. To simulate the 50% voltage sag, the SCR-based experimental set was constructed.

  • PDF

Environmental Effect Analysis of Electromagnetic Induction in Express Electric Railway (고속 전철구간에서의 전력유도 환경 영향 분석)

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyung-Dong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.1
    • /
    • pp.19-23
    • /
    • 2010
  • The Electromagnetic Interference could occur due to power line on the telecommunication service. The Countermeasure is practised by legal law. Various affecting factors are described in the law. In this paper, an effect by pipeline especially in the ground, power feeding plant, and curved railway sector is analyzed as environmental factors which are not included in the law. By the practical measurement, it appears that the measured voltages on the spots with underground pipeline are grouped into lower voltage level, induced voltage tends to be high near power feeding plant, and also in the curved railway line. These analytical results can be meaningly considered in the application of countermeasure.

  • PDF

Control of DSTATCOM for Line Voltage Regulation (선로 전압 조정을 위한 DSTATCOM 제어)

  • Jung, Soo-Young;Kim, Tae-Hyun;Moon, Seung-Il
    • Journal of IKEEE
    • /
    • v.5 no.2 s.9
    • /
    • pp.146-152
    • /
    • 2001
  • Two control techniques - PI and LQR(Linear Quadratic Regulator) - of DSTATCOM (Distribution Static Synchronous Compensator) for line voltage regulation in distribution system are presented. It is shown that the voltage waveform is improved if the proposed methods are applied in IEEE 13 radial distribution system using PSCAD/EMTDC package in case of single line-to-ground fault. The three cases - without control, with PI control and with LQR control - are compared. The LQR control is shown to be best in respect of response profile and control effort required among them.

  • PDF