• Title/Summary/Keyword: Line-by-Line Model

Search Result 3,763, Processing Time 0.031 seconds

The Propagation Characteristics of the Pressure in the Volume Loaded Fluid Transmission Line (체적부하를 갖는 유체 전달관로의 압력전파 특성)

  • 윤선주;손병진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3075-3083
    • /
    • 1994
  • The applications of the electrical transmission line theory to the pressure propagation characteristics in the volume loaded fluid transmission line with step and impulse input wave is demonstrated in this paper. The method is based on the premise that the time response is the inverse Fourier transform of frequency spectrum of the wave which spectrum is a product of frequency spectrum of input pressure wave and system transfer function. The frequency response and transient response of step and impulse input wave in the volume loaded fluid transmission line is analysed by the Laplace transform and inverse Laplace transform with FFT numerical algorithm. The numerical solution of the distributed friction model is compared with the average friction model and the infinite product model. And the result is showed that FFT method may have major advantages for the simulation of fluid circuitary.

Real Time Simulation of the High Speed Multibody Tracted Vehicle for Track Tension Control (궤도장력 조절을 위한 다물체로 이루어진 고소궤도차량의 실시간 시뮬레이션)

  • 백승한;이승종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.261-264
    • /
    • 1997
  • In case of high speed and high mobility multibody tracked vehicle, it is hard to develop the realtime simulation model for track tension control because of the hundreds of highly nonlinear equations. In order to design more trustworthy realtime simulator for track tension control, it is necessary to use off-line tracked vehicle model. In this study, a step by step procedure is presented to develop realtime simulation model based on off-line tracked vehicle model. Simulation results show that modified off-line multibody tracked vehicle model can be used for real time simulation to control the track tension.

  • PDF

The development of FE-based on-line model for the precise prediction of work roll thermal profile in hot strip rolling (열간 압연 시 워크 롤의 열 변형 정밀 예측을 위한 유한요소법 기반의 온라인 모델 개발)

  • Choi J. W.;Huang H. D.;Lee J. H.;Hwang S. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.329-335
    • /
    • 2004
  • An, FE-based, on-line model is presented for the rapid and precise prediction of roll thermal profile in hot strip rolling. The validity of the model is demonstrated through comparison with FE-based off-line model which was verified by measurements. Also demonstrated is its capability of reflecting the effect of diverse process variables.

  • PDF

A Study on Estimating Line Constants Using the 5-Conductors Equivalent Model (5도체군 등가모델을 이용한 선로정수 예측에 관한 연구)

  • Lee, H.M.;Oh, K.H.;Lee, C.M.;Chang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.443-445
    • /
    • 2001
  • This paper describes an estimate of line constants using the five-conductors equivalent model. Actually, a catenary system is composed of the five-conductors equivalent model. Therefore, we made up the five conductors equivalent model of a catenary system by applying a method of inverse matrix. Finally, we estimated line constants using the five-conductors equivalent model. To verify the results, we compared estimated line constants with measured those.

  • PDF

Analysis on Induced Surge Voltage of Electric Car Line affected by Lightning in Rapid-Transit Railway System (고속철도시스템에서 낙뢰로 인해 전차선에 유도되는 서지전압의 해석)

  • Lee, Sung-Gyen;Lee, Kun-A;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.65-70
    • /
    • 2015
  • Lightning is one of hazards affecting the rapid-transit railway system. There are two effects, which are direct lightning surge to electric car line and induced lightning surge. Protection methods for the direct lightning surge are studied with various occasions, however, study of induced lightning surge is insufficient in spite of a large or small effects. In this paper, it is analysed the way that serge voltage is induced to electric car line by lightning strikes. By modeling the propagation process and the coupling phenomenon of electromagnetic wave produced by lightning strikes, it is achieved to make integrative circuit model combined with existing electric car model. The study is conducted into three different waveform of electromagnetic wave produced by lightning; rectangular wave, double exponential distribution wave, triangle wave. It is also simulated that the inducing serge is coupled to electric car line in an arbitrary location. The simulation results in that, when rapidly changing rectangular wave is supplied, maximum power is induced to electric car line.

Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line (22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

3D line segment detection using DEM (DEM을 이용한 3차원 선소추출)

  • Lee, Jeong-Yong;Woo, Dong-Min
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.141-143
    • /
    • 2004
  • This paper represents 3D line segment extraction method, which can be used in generating 3D rooftop model. The core of our method is that 3D line segment is extracted by using line fitting of elevation data on 2D line coordinates of ortho-image. In order to use elevations in line fitting, the elevations should be reliable. To measure the reliability of elevation, in this paper, we employed the concept of self-consistency. We carry out the experiment of 3D line extraction using synthetic images generated from Avenches data set of Ascona aerial images.

  • PDF

Forecasting Passenger Transport Demand Using Seasonal ARIMA Model - Focused on Joongang Line (계절 ARIMA 모형을 이용한 여객수송수요 예측: 중앙선을 중심으로)

  • Kim, Beom-Seung
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.4
    • /
    • pp.307-312
    • /
    • 2014
  • This study suggested the ARIMA model taking into consideration the seasonal characteristic factor as a method for efficiently forecasting passenger transport demand of the Joongang Line. The forecasting model was built including the demand for the central inland region tourist train (O-train, V-train), which was opened to traffic in April-, 2013 and run in order to reflect the recent demand for the tourism industry. By using the monthly time series data (103) from January-, 2005 to July-, 2013, the optimum model was selected. The forecasting results of passenger transport demand of the Joongang Line showed continuous increase. The developed model forecasts the short-term demand of the Joongang Line.

Pressure Control of a Pneumatic Conrol system with a long Transmission Line (긴 전달관로를 갖는 공압제어계의 압력 제어)

  • Jang, Ji-Seong;Lee, Kwang-Kuk;Choi, Myung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.567-576
    • /
    • 2003
  • In this study, a robust controller to control pressure in a pneumatic pressure vessel with a long transmission line is proposed. Frequency response of transmission line using compressible fluid is changed by the flowing state of the fluid. So, it a fixed gain controller designed based on a model supposed the flowing state to a specific state, the performance of the control system could be degraded because of the modelling error. The controller designed in this study is composed of two parts. One is a feedback controller to improve a feedback characteristics and to compensate the influence of the variation of transfer characteristics of a transmission line owing to the change of flowing state and the other is a feedforward controller to regulate command fallowing performance. The experimental results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model or the transmission line. Therefore, the designed controller can be utilized for the Performance improvement of a Pressure control system with a long transmission line using compressible fluid.

Web Guide Process in Cold Rolling Mill : Modeling and PID Controller

  • Ahn, Byoung-Joon;Park, Ju-Yong;Chang, Yu-Shin;Lee, Man-Hyung
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.7
    • /
    • pp.1074-1085
    • /
    • 2004
  • There are many intermediate web guides in cold rolling mills process such as CRM (cold rolling mill), CGL (continuous galvanizing line), EGL (electrical galvanizing line) and so on. The main functions of the web guides are to adjust the center line of the web (strip) to the center line of the steel process. So they are called CPC (center position control). Rapid process speed cause large deviation between the center position of the strip and the process line. Too much deviation is not desirable. So the difference between the center position of the strip and the process line should be compensated. In general, the center position control of the web is obtained by the hydraulic driver and electrical controller. In this paper, we propose modelling and several controller designs for web-guide systems. We model the web and guide by using geometrical relations of the guide ignored the mass and stiffness of the web. To control the systems, we propose PID controllers with their gains tuned by the Ziegler-Nichols method, the H$\_$$\infty$/ controller model-matching method, and the coefficient diagram method (CDM). CDM is modified for high order systems. The results are verified by computer simulations.