• 제목/요약/키워드: Line-Neutral fault

검색결과 44건 처리시간 0.029초

산업현장 정전 및 결상사고 감지회로 토폴로지 연구 (A Study on Circuit Topology for the Electrical Power Failure and Open-Phase Fault Detection of Industrial Field)

  • 박동훈;곽동걸;정회중;전호진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.540-542
    • /
    • 2019
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground of three phase. The open-phase detection system is also configured to Y-wiring of three capacitance devices of the same capacity to each line of three phase power source R-S-T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF

배전계통에서 전력용 변압기의 접지저항 영향에 관한 연구 (A Study on the Grounding Resistance Effects of Power Transformer in Electric Distribution Systems)

  • 김경철;정지원;이규진;이강수;최선규
    • 조명전기설비학회논문지
    • /
    • 제24권2호
    • /
    • pp.113-119
    • /
    • 2010
  • 안전한 접지설계는 사고 시에 대지로 고장전류를 흘려보내는 수단과 인체가 사고기기에 접촉 시에 위험에 노출되지 않도록 하는데 있다. 변압기 중성점 접지는 1선 지락사고 시 중성점전위가 허용치 이하가 되도록 접지되어야 한다. 변압기 외함 접지는 절연사고로 외함에 전류가 흐를 때 인체 허용전압과 전류 이내로 저감시키는 목적으로 사용되고 있다. 본 논문에서는 사고 시 중성점 전위와 접촉전압을 계산하여 배전 변압기의 접지저항 영향을 심도있게 분석하였다.

풍력발전 계통연계 변압기의 결선에 따른 배전계통의 고장전류에 관한 연구 (A Study on the Fault Current of Distribution System according to Connection of Wind Turbine Generation Grid-Connected Transformer)

  • 안해준;노경수;김현구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.369-371
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

154 kV 변전소 주변압기의 용량 및 운전조건이 22.9 kV 배전계통의 고장전류에 미치는 영향 (An Investigation on the Fault Currents in 22.9 kV Distribution System Due to the Increased Capacity and Operating Conditions of Power Transformers in 154 kV Substation)

  • 조성수;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.302-310
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity and operating conditions of power transformers in 154 kV substation, the fault currents in distribution system were calculated by the conventional method and simulations of PSCAD/EMTDC program. Consequently, under the condition of the parallel operation of transformers, the fault currents exceed the nominal current of the breakers in some areas. Without NGR at the secondary neutral of the transformer, the current of single line-to-ground fault was bigger than that of 3-phase fault. Therefore, the results clearly show that the measures to limit the fault currents in distribution system are needed when the increased capacity of power transformers is introduced into 154 kV substation.

MATLAB & SIMULINK에서 풍력발전 계통연계 변압기결선과 고장전류와의 관계 (The Relationship between Wind Power Generation Grid-connected Transformer Winding Connection and Fault Current in MATLAB & SIMULINK)

  • 안해준;김현구;장길수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.307-309
    • /
    • 2008
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

변압기결선에 따른 풍력발전시스템의 고장전류에 대한 시뮬레이션 (Simulation for fault current of wind turbine generating system following transformer winding connection)

  • 안해준;노경수
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.454-457
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by MARTLB & SIMULINK. The simulation shall be performed by assuming single line to ground fault generated in the system Generator power, rotor speed, terminal voltage, system voltage, and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

전력용변압기 단선 보호용 NGR 성능 개선 (The Improvement of NGR for Power Transformer Open Circuit Protection)

  • Kang, Y.W.;Shim, E.B.;Kwak, J.S.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.83-88
    • /
    • 2004
  • As the electric system is getting larger to meet the increasing demand for electric power, the rating of power apparatus is becoming inevitably higher in its working voltage and larger in its capacity. According to KEPCO reports, power transformers in the KEPCO system have undergone troubles such as winding short insulation breakdowns every year since 1981. the cause of this troubles were high one line grounding fault currents in KEPCO systems that had direct grounding systems. KEPCO has installed the NGR(neutral grounding reactor) to lower this fault current and reduced winding short insulation breakdowns in power transformers. But when a circuit breaker opened a no load bus, some trips of circuit breakers for protecting transformer have occurred by mal-operation of 59GT(overvoltage ground relay) that detect disconnection of NGR. Therefore, in this paper, we analyzed the cause and examined the effect of time delav circuit to prevent wrong operation of 59GT.

  • PDF

IoT 기반의 결상사고 원격알람 시스템에 관한 연구 (A Study on Remote Alarm System of Open-phase Faults based on IoT)

  • 정회중;곽동걸;최신형;김춘삼;양기철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.4-6
    • /
    • 2018
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground(G) of three phase. And the open-phase detection system is configured to Y-wiring of three capacitance devices of the same capacity to each line of three phase power source R-S-T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF

MATLAB&SIMULINK에서 변압기 결선에 따른 풍력발전 시스템의 영향 평가 (Evaluation on Effect of Wind Power Generation System According to Transformer Winding Connection at Matlab&Simulink)

  • 안해준;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.772-773
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind power generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, rotor speed, terminal voltage, system voltage, and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

MATLAB/Simulink에서 계통연계 풍력발전시스템의 특성해석에 대한 시뮬레이션 (Simulation for Characteristics Analysis of Grid-connected Wind Power Generation System on MATLAB/Simulink)

  • 노경수;안해준
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.18-25
    • /
    • 2008
  • 본 논문은 HATLAB/Simulink에서 계통연계 풍력발전시스템의 특성해석을 위한 모델링을 제안하여 시뮬레이션을 수행한다. 이를 위해 풍속의 변화에 따른 발전기의 출력제어를 위해 피치제어를 수행하며, 연계변압기의 결선방법에 따른 고장전류의 변화를 살펴봄으로 하여 연계변압기의 결선방법과 고장전류와의 상관관계를 제시하였다. 아울러 풍력발전시스템의 연계변압기 중성점접지방식이 고장전류에 미치는 영향을 살펴본다. 계통에서의 1선 지락고장에 대해 연계변압기의 4가지 결선방식의 차이에 따른 고장전류, 전압 및 발전기의 특성 변화를 확인할 수 있었으며 중성점 접지방식의 차이에 따른 고장전류의 변화를 확인하였다. 사례연구를 통하여 제안한 Simulink에서의 시뮬레이션 모델의 효용성을 입증하였다.