• Title/Summary/Keyword: Line detection

Search Result 1,781, Processing Time 0.029 seconds

Development of Biotelemetry Method by Combining the SSBL Method and the Pinger Synchronizing Method (1) - Design and production of system - (SSBL 방식과 핑거동기 방식을 조합한 바이오텔레메터리 방식의 개발 (1) -시스템의 설계 및 제작 -)

  • 박주삼;고탁창언
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.218-229
    • /
    • 2003
  • A new biotelemetry method that the installation and the treatment of equipment is convenient and the instantaneously detailed location of the fish attached the pinger is able to track comparatively easily was developed. The receiving system in this biotelemetry method was advanced for track the detailed behavior of the fish by the miniature tracking pinger, because it was a burden to fish to add the pinger with the water temperature and the pressure sensor. By combining of the super short base line (SSBL) method to detect the direction of pinger and the pinger synchronizing method to measure the range from receiving transducer to pinger, the three dimensional locations of fish to the receiving transducer is gotten instantaneously. The receiving system is devised to realize the high precision or wide detection range by application of the basic design method for receiving system of biotelemetry developed by the present authors and the hydrophone array configuration. The measurement distance error in the pinger synchronizing method is minimized through the correction of which the deviation of transmission pluse period of pinger is caused by changing water temperature. A prototype system which is able to track the instantaneously detailed location of the fish by the SSBL and pinger synchronizing biotelemetry (SPB) method was produced.

QTL Scan for Meat Quality Traits Using High-density SNP Chip Analysis in Cross between Korean Native Pig and Yorkshire

  • Kim, S.W.;Li, X.P.;Lee, Y.M.;Choi, Y.I.;Cho, B.W.;Choi, B.H.;Kim, T.H.;Kim, J.J.;Kim, Kwan-Suk
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.9
    • /
    • pp.1184-1191
    • /
    • 2011
  • We attempted to generate a linkage map using Illumina Porcine 60K SNP Beadchip genotypes of the $F_2$ offspring from Korean native pig (KNP) crossed with Yorkshire (YS) pig, and to identify quantitative trait loci (QTL) using the line-cross model. Among the genotype information of the 62,136 SNPs obtained from the high-density SNP analysis, 45,308 SNPs were used to select informative markers with allelic frequencies >0.7 between the KNP (n = 16) and YS (n = 8) F0 animals. Of the selected SNP markers, a final set of 500 SNPs with polymorphic information contents (PIC) values of >0.300 in the $F_2$ groups (n = 252) was used for detection of thirty meat quality-related QTL on chromosomes at the 5% significance level and 10 QTL at the 1% significance level. The QTL for crude protein were detected on SSC2, SSC3, SSC6, SSC9 and SSC12; for intramuscular fat and marbling on SSC2, SSC8, SSC12, SSC14 and SSC18; meat color measurements on SSC1, SSC3, SSC4, SSC5, SSC6, SSC10, SSC11, SSC12, SSC16 and SSC18; water content related measurements in pork were detected on SSC4, SSC6, SSC7, SSC10, SSC12 and SSC14. Additional QTL of pork quality traits such as texture, tenderness and pH were detected on SSC6, SSC12, SSC13 and SSC16. The most important chromosomal region of superior pork quality in KNP compared to YS was identified on SSC12. Our results demonstrated that a QTL linkage map of the $F_2$ design in the pig breed can be generated with a selected data set of high density SNP genotypes. The QTL regions detected in this study will provide useful information for identifying genetic factors related to better pork quality in KNP.

PNA-Mediated PCR Clamping for the Detection of EGFR Mutations in Non-Small Cell Lung Cancer (비소세포폐암에서 PNA-Mediated PCR Clamping을 이용한 EGFR 돌연변이 분석법)

  • Lee, Kye-Young;Kim, Hee-Joung;Kim, Sun-Jong;Yoo, Gwang-Ha;Kim, Won-Dong;Oh, Seo-Young;Kim, Wan-Seop
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.4
    • /
    • pp.271-278
    • /
    • 2010
  • Background: Recent studies have demonstrated that the epidermal growth factor receptor (EGFR) genotype is the most important predictive marker to EGFR-tyrosine kinase inhibitors (TKIs) and first-line gefitinib treatment will be approved in the near future for use in non-small cell lung cancer (NSCLC) patients with the EGFR mutation. Direct sequencing is known to be the standard for detecting EGFR mutations; however, it has limited sensitivity. Peptide nucleic acids (PNA)-mediated PCR clamping method is a newly introduced method for analyzing EGFR mutations with increased sensitivity and stability. Methods: A total of 71 NSCLC patients were analyzed for EGFR mutations using the PNA-mediated PCR clamping technique. Sixty-nine patients were analyzed for clinicopathologic correlation with EGFR genotype; 2 patients with indeterminate results were excluded. In order to determine EGFR-TKI drug response, 57 patients (42 gefitinib, 15 erlotinib) were included in the analysis. Results: The EGFR mutation rate was 47.8%. Being female, a non-smoker, and having adenocarcinoma were favorable clinicopathologic factors, as expected. However, more than a few smokers (33.3%), male (28.1%), and patients with non-adenocarcinoma (28.6%) had the EGFR mutation. Having a combination of favorable clinicopathologic factors did not increase the EGFR mutation rate significantly. Drug response to EGFR-TKIs showed significant differences depending on the EGFR genotype; ORR was 14.3% for wild type vs 69.0% for mutant type; DCR is 28.6% for wild type vs 96.6% for mutant type. The median EGFR-TKI treatment duration is 7.6 months for mutant type group and 1.4 months for wild type group. Conclusion: EGFR genotype determined using the PNA-mediated PCR clamping method is significantly correlated with the clinical EGFR-TKI responses and PNA-mediated PCR.

DEHP, DEP and DBP Exposure Analysis using Urinary Metabolites of Gyonggi Province University Students

  • Lee, JangWoo;Kho, YoungLim;Kim, SungKyoon;Choi, Kyungho;Hwang, SeongHee;Jeong, Jeeyeon;Kim, Pangyi
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.408-417
    • /
    • 2013
  • Objectives: Phthalates are used as plasticizers in polyvinyl chloride (PVC) plastics. As phthalate plasticizers are not chemically bound to the PVC, they can leach, migrate or evaporate into indoor air and atmosphere, foodstuffs, other materials, etc. Therefore, humans are exposed through ingestion, inhalation, and dermal exposure over their entire lifetime, including during intrauterine development. In particular, university students have a great number of opportunities to contact products including phthalates during campus life (food packaging, body care products, cosmetic, lotions, aftershave, perfume etc.). The purpose of this study was to examine levels of phthalate exposure as undergraduate students begin to use pharmaceuticals and personal care products including phthalates. Methods: Phthalate metabolites, mono-ethyl phthalate (MEP), mono-n-butyl phthalate (MnBP), mono-isobutyl phthalate (MiBP), mono-2- ethylhexyl phthalate (MEHP), {(mono-(2-ethyl-5-hydroxyhexyl) phthalate (MEHHP}, and mono-(2-ethlyl-5-oxohexyl) phthalate (MEOHP} were examined. 80 urine samples collected from university students were analyzed using LC/MS/MS(API 4000, Applied Bioscience) with on-line enrichment and columnswitching techniques. This study was carried out at Y university located in Gyonggi Province from 2008 to 2011. Results: The detection limit of phthalate metabolites were 0.03 ng/mL for MEP, 0.11 ng/mL for MnBP, 0.08 ng/mL for MiBP, 0.93 ng/mL for MEHP, 0.19 ng/mL for MEOHP and 0.16ng/mL for MEHHP. MnBP showed the highest urinary levels (median: 31.6 ug/L, 24.8 ug/g creatinine (cr)). Concentrations were also high for MEHHP (median: 24.1 ug/L, 19.0 ug/g cr), followed by MEOHP (median: 22.8 ug/L, 17.9 ug/g cr). In individual cases, the maximum level reached up to 348 ug/L, and 291 ug/g cr, respectively. The urinary and creatinine adjusted levels of MEP were lower than those for DBP and DEHP metabolites, but were higher in 95th percentiles. As a result, the mean daily DEP intake value was 2.3 ${\mu}g/kg$ bw/day, 3.5 ${\mu}g/kg$ bw/day for DEHP and 4.9 ${\mu}g/kg$ bw/day for DBP. Conclusion: These students' phthalate exposure levels were below the international safe level set by the EU, but higher than the 2012 KFDA survey of the age group from 3 to 18.

An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam (흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석)

  • Oh, Seok-Hoon;Suh, Baek-Soo;Kim, Joong-Ryul
    • Journal of the Korean earth science society
    • /
    • v.31 no.6
    • /
    • pp.563-572
    • /
    • 2010
  • Both multi-channel temperature monitoring and geophysical electric survey were performed together for an embankment to assess the leakage zone. Temperature variation according to space and time on the inner parts of engineering constructions (e.g.: dam and slope) can be basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation (e.g.: cracks and defects) could be generated by various factors. Seepage or leakage of water through the cracks or defects in old dams will directly cause temperature anomaly. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For that matter, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body. Geophysical data by electrical method are also added to help interpret data.

A Study on Optical Coherence Tomography System by Using the Optical Fiber (광섬유를 이용한 광영상단층촬영기 제작에 관한 연구)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, we have studied the OCT(Optical Coherence Tomography) system which has been advantages of high resolution, 2-D cross-sectional images, low cost and small size configuration. The characteristics of light source determine the resolution and coherence length. The light source has a commercial SLD with a central wavelength of 1,285 ill11, 35.3 nm(FWHM). The optical delay line is necessary to make equal with the optical path length to scattered light or reflected light from a sample. In order to make equal the optical path length, the stage that is attached to a reference mirror is controled by a step motor. And the interferometer is configured with the Michelson interferometer by using a single mode fiber, and the scanner can be focused on the sample by using a reference ann Also, the 2-dimension cross-sectional images were measured with scanning the transverse direction of the sample by using a step motor. After detecting the internal signal of lateral direction, a scanner is moved to obtain the cross-sectional image of 2-dimension by using step motor. A photodiode, which has high detection sensitivity and excellent noise characteristics has been used. The detected small signal has a noise and interference. After filtering and amplifying the signal, the output signal is demodulated the waveform And then, a cross-sectional image is seen through converting this signal into a digitalized signal by using an AID converter. The resolution of the sample is about 30${\mu}{\textrm}{m}$, which corresponds to the theoretical resolution. Also, the cross-sectional images of onion cells were measured in real time scheme.

Development of Software Correlator for KJJVC (한일공동VLBI상관기를 위한 소프트웨어 상관기의 개발)

  • Yeom, J.H.;Oh, S.J.;Roh, D.G.;Kang, Y.W.;Park, S.Y.;Lee, C.H.;Chung, H.S.
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.567-588
    • /
    • 2009
  • Korea-Japan Joint VLBI Correlator (KJJVC) is being developed by collaborating KASI (Korea Astronomy and Space Science Institute), Korea, and NAOJ(National Observatory of Japan), Japan. In early 2010, KJJVC will work in normal operation. In this study, we developed the software correlator which is based on VCS (VLBI Correlation Subsystem) hardware specification as the core component of KJJVC. The main specification of software correlator is 8 Gbps, 8192 output channels, and 262,144-points FFT (Fast Fourier Transform) function same as VCS. And the functional algorithm which is same as specification of VCS and arithmetic register are adopted in this software correlator. To verify the performance of developed software correlator, the correlation experiments were carried out using the spectral line and continuum sources which were observed by VERA (VLBI Exploration of Radio Astrometry), NAOJ. And the experimental results were compared to the output of Mitaka FX correlator by referring spectrum shape, phase rate, and fringe detection and so on. Through the experimental results, we confirmed that the correlation results of software correlator are the same as Mitaka FX correlator and verified the effectiveness of it. In future, we expect that the developed software correlator will be the possible software correlator of KVN (Korean VLBI Network) with KJJVC by introducing the correlation post-processing and modifying the user interface as like GUI (Graphic User Interface).

The Study on Centralization & Electronic for Maintenance Efficiency of Ground Signaling System (지상신호설비의 유지보수 효율화를 위한 집중화 및 전자화 연구)

  • Baek, Jong-Hyen;Kim, Yong-Kyu;Lee, Kang-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2983-2988
    • /
    • 2010
  • The train control system used in Gyeongbu-line is classified in ATC, IXL and CTC. Domestic railway signaling systems are being developed by electrification. In these systems the electrification of interlocking reaches 57% and the safety equipments of railway crossings in trackside devices have completed their development into an integrated system. Block systems of all the existing sections have not yet electrified and integrated so that they need a number of complement in terms of construction and maintenance. For ABS currently used in existing domestic lines, and LEU being installed in Gyeongbu and Honam lines, although a train is controlled by the signaling information of the same train in the same location, the system is separately installed so that the same information is separately divided and transmitted at the each distinct system. Therefore, in the conventional ABS and LEU, there are a lot of duplicate installed compartments such as lamp detection and a power supply unit. Hence, we have a lot of problems: for maintenance, a lot of manpower and costs need to be invested and the overall manufacturing costs get higher, as well as the construction costs by duplicate. Therefore, this paper suggest design to develop an integrated electronic Block Control Unit by the integration of the currently used ABS, and communication and electronic technology. We are to monitor and manage the block systems in the corresponding station by integrating. And we are to transmit information together with LEU, which is an ATS wayside transmitter.

3D Node Deployment and Network Configuration Methods for Improvement of Node Coverage and Network Connectivity (커버리지와 네트워크 연결성 향상을 위한 3차원 공간 노드 배치 및 망 구성 방법)

  • Kim, Yong-Hyun;Kim, Lee-Hyeong;Ahn, Mirim;Chung, Kwangsue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37B no.9
    • /
    • pp.778-786
    • /
    • 2012
  • Sensors that are used on wireless sensor networks can be divided into two types: directional sensors, such as PIR, image, and electromagnetic sensors; and non-directional sensors, such as seismic, acoustic and magnetic sensors. In order to guarantee the line-of-sight of a directional sensor, the installation location of the sensor must be higher than ground level. Among non-directional sensors, seismic sensors should be installed on the ground in order to ensure the maximal performance. As a result, seismic sensors may have network connectivity problems due to communication failure. In this paper, we propose a 3D node deployment method to maximize the coverage and the network connectivity considering the sensor-specific properties. The proposed method is for non-directional sensors to be placed on the ground, while the directional sensor is installed above the ground, using trees or poles, to maximize the coverage. As a result, through the topology that the detection data from non-directional sensors are transmitted to the directional sensor, we can maximize the network connectivity. Simulation results show that our strategy improves sensor coverage and network connectivity.

An Experimental Comparative Study of Radiography, Ultrasonography and CT Imaging in the IV Catheter Fragment (정맥내 카테터 조각의 엑스선, 초음파 및 CT 영상의 실험적 비교 연구)

  • Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.185-191
    • /
    • 2016
  • The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon$^{(R)}$ IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose ($0.2139mSv{\cdot}Gy^{-1}{\cdot}cm^{-2}$) form DAP DAP ($0.93{\mu}Gy{\cdot}m^2 $), and dose length product (DLP) ($201mGy{\cdot}cm$) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.