• 제목/요약/키워드: Line Trace

검색결과 194건 처리시간 0.025초

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

MC3T3 preosteoblast cell line의 5-(and-6)-carboxy-2',7'-dichlorofluorescein diacetate, succinimidyl ester mixed에 의한 fluorescent labelling (FLUORESCENT LABELLING OF MC3T3 CELL LINE BY 5-(AND-6)-CARBOXY-2', 7'-DICHLOROFLUORESCEIN DIACETATE, SUCCINIMIDYL ESTER MIXED)

  • 국민석
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권6호
    • /
    • pp.461-467
    • /
    • 2005
  • Background. 5-(and-6)-carboxy-2',7'-dichlorofluorescein diacetate, succinimidyl ester mixed (CFSE) is the fluorescent labelling agent of living cells and used to trace the cells in vivo after transplatnation of various cells. The CFSE labelled cells can maintain fluorescence for up to 7 days after labelling. The MC3T3-E1 cell line (MC3T3) has been used for many studies about osteoblast, which is well known as a mouse preosteoblast. So the CFSE would be used to trace the transplanted MC3T3. However there are few reports about CFSE labelling of MC3T3. This study is aimed to know about adequate concenturation and incubation time of CFSE to MC3T3. Materials and methods. The MC3T3 was incubated in a humidified atmosphere of 95% air with 5% $CO_2$ at $37^{\circ}C$ using ${\alpha}$-minimal essential medium (${alpha}$-MEM) containing10% FBS and gentamycin. Ten mM CFSE solution in dimethylsulphoxide (DMSO: 1%) was diluted with phosphate buffered saline (PBS) and final concentration of culture medium was, respectively, 5, 10, 15, 20, 25 and 30 ${{\mu}M$. Then the MC3T3 was incubated with CFSE in a humidified atmosphere of 95% air with 5% $CO_2$ at $37^{\circ}C$ for 5, 10, 15, 20, 25, 30, 35, 40 and 45 minutes in each concentration. The fluorescence of CFSE labelled cells was analysed with a inverted fluorescence microscope. The duration of cell labelling was also studied. Trypan blue dye exclusion test was done for cell viability. Results. For concentration between 5 and 10 ${\mu}M$, CFSE did not significantly label the MC3T3 in vitro. The destruction of MC3T3 was observed at the concentration of 20 ${\mu}M$. In the concentration of 15 ${\mu}M$, the best labelling was obtained at an incubation period between 15 and 30 minutes. The MC3T3 labelled with an incubation period of 15 minutes at 15 ${\mu}M$ was still fluorescent 7 days after CFSE labelling. The mean cell viability was 95.93%. Conclusion. These results suggests an incubation period of 15 minutes at 15 ${\mu}M$ of CFSE provides best labelling of MC3T3 in vitro.

제품 계열 공학에서의 산출물간의 추적성 기법 (A Method of Applying Traceability among Product Line Engineering Artifacts)

  • 라현정;장수호;김수동
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제32권4호
    • /
    • pp.237-246
    • /
    • 2005
  • 제품계열 공학(Product Line Engineering, PLE)은 핵심 자산을 이용하여 어플리케이션을 경제적으로 개발하는 대표적인 재사용 기술이다. PLE는 프레임웍(Framework) 공학과 어플리케이션 공학으로 구성된다. 프레임웍 공학은 한 도메인 내에 있는 여러 패밀리 멤버들이 가지고 있는 공통적인 기능인 핵심 자산을 개발하는 단계이고, 어플리케이션 공학은 핵심 자산을 패밀리 멤버에 맞게 인스턴스화하여 어플리케이션을 생산하는 단계이다. PLE는 핵심 자산을 이용하여 특정 어플리케이션을 개발함으로써 재사용성이 높을 뿐 아니라 어플리케이션을 적은 시간과 노력으로 만들 수 있으므로 개발하는 효율성도 높다. 그러나, PLE 개발 절차에 대한 산출물 정의 및 템플릿 제공이 미비하여 개발자들이 PLE 프로세스를 따라 산출물을 만드는데 어려움이 있고, 산출물간 관계 정의가 충분하지 못하여 산출물간 일관성을 유지하기 힘들어 개발자들은 PLE 프로세스의 실용적 적용에 어려움이 있다. 본 논문에서는 rLE의 핵심단계인 프레임웍 공학 과정의 각 단계마다 도출되는 산출물의 메타모델을 정의하고 각 산출물간의 추적 관계를 추적성 맵(Traceabitliy Map)으로 나타내며 산출물간 추적 관계를 적용할 수 있는 지침을 제시한다 마지막으로, 추적성 맵에 대한 평가와 적용되는 방법을 제시한다.

캐쉬 메모리가 버스 트래픽에 끼치는 영향 (The Effects of Cache Memory on the System Bus Traffic)

  • 조용훈;김정선
    • 한국통신학회논문지
    • /
    • 제21권1호
    • /
    • pp.224-240
    • /
    • 1996
  • It is common sense for at least one or more levels of cache memory to be used in these day's computer systems. In this paper, the impact of the internal cache memory organization on the performance of the computer is investigated by using a simulator program, which is wirtten by authors and run on SUN SPARC workstation, with several real execution, with several real execution trace files. 280 cache organizations have been simulated using n-way set associative mapping and LRU(Least Recently Used) replacement algorithm with write allocation policy. As a result, 16-way setassociative cache is the best configuration, and when we select 256KB cache memory and 64 byte line size, the bus traffic ratio was decreased compared to that of the noncache system so that a single bus could support almost 7 processors without any delay and degradationof high ratio(hit ratio was 99.21%). The smaller the line size we choose, the little lower hit ratio we can get, but the more processors can be supported by a single bus(maximum 18 processors). Therefore, using a proper cache memory organization can make a single bus structure be able to support multiple processors without any performance degradation.

  • PDF

Blue excesses in different evolutionary stages of massive star-forming regions

  • Jin, Mihwa;Lee, Jeong-Eun;Kim, Kee-Tae
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.53.3-53.3
    • /
    • 2015
  • We analyzed both HCN J=1-0 and HNC J=1-0 line profiles to study the inflow motions in different evolutionary stages of massive star formation; infrared dark clouds (IRDCs), high-mass protostellar object (HMPOs), and ultra-compact HII regions (UCHIIs). The infall asymmetry in HCN spectra seems to be prevalent throughout all the three evolutionary phases, with IRDCs showing the largest excess in blue profile. In the case of HNC spectra, the prevalence of blue sources does not appear, excepting for IRDCs. We suggest that this line is not appropriate to trace infall motion in evolved stages of massive star formation because of an astrochemical effect. This result spotlights the importance of considering chemistry in dynamical study in star-forming regions. The fact that the IRDCs show the highest blue excess in both infall tracers indicates that the most active infall occurs in the early phase of star formation, i.e., the IRDC phase rather than in the later phases. However, the UCHIIs is likely still accreting matters. We also found that the absorption dips of the HNC spectra in all blue sources are red--shifted relative to their central velocities. These red-shifted absorption dips may indicate the observational signature of overall collapse although observations with better resolutions are needed to examine this feature more in detail.

  • PDF

네트워크 컴퓨터를 위한 자바 기반의 성능감시기 (A Java-based Performance Monitor for Networked Computer)

  • 김봉준;김동호;황석찬;김명호;최재영
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제27권2호
    • /
    • pp.160-168
    • /
    • 2000
  • 본 논문에서는 네트워크 컴퓨터를 이용하여 병렬 프로그래밍 환경에서 수행되는 프로그램의 성능을 추적하고 평가하기 위한 온라인/일괄처리-사건/시간 기반형 성능 감시기를 제안한다. 본 논문의 JaNeC 성능 감시기는 자바로 구현되어 있으므로 이기종 컴퓨터사이의 시스템 이식성이 뛰어나며, 웹 기반의 그래픽 콘솔을 제공하여 사용자에게 친숙한 인터페이스를 제공한다. 본 논문에서 제시한 성능 감시기는 사용자가 프로그램 실행시에 발생한 이벤트를 보다 쉽게 분석할 수 있도록 태스크나 이벤트를 선택할 수 있는 필터 기능과 TimeLine, Task View, Task History, Message Passing View, Host CPU View 기능 등으로 구성되어 있다.

  • PDF

구부러진 전송선에서 비아 홀 펜스에 의한 누화 감소 해석 (Analysis of Crosstalk Reduction by Metal Filled Via Hole Fence in Bent Transmission Lines)

  • 김종호;한재권;박동철
    • 한국전자파학회논문지
    • /
    • 제16권10호
    • /
    • pp.1036-1042
    • /
    • 2005
  • 다중 전송선들로 회로를 구성할 경우 필요에 의해 중간 부분이 구부러진 형태를 갖기도 하는데, 이때의 누화는 금속으로 채워진 비아 홀 펜스를 전송선 사이에 위치시킴으로써 감소시킬 수 있다. 이러한 효과를 해석하기 위하여 비아 홀 펜스를 포함한 다중 전송선을 구간별로 나누고, 전송선 구간을 위한 회로 개념 접근법과 비아흘 구간을 위한 임피던스 모델링을 이용하고, 각 구간을 ABCD 행렬로 나타내어 직렬 연결하는 방법을 제안하였다. 마지막으로 이 방법에 의한 최종 계산 결과가 일부 저주파 대역을 제외하고 대략 3 dB 이내의 범위로 측정 결과와 일치함을 확인하였다.

A SUMMARY OF 50th OECD/NEA/CSNI INTERNATIONAL STANDARD PROBLEM EXERCISE (ISP-50)

  • Choi, Ki-Yong;Baek, Won-Pil;Kang, Kyoung-Ho;Park, Hyun-Sik;Cho, Seok;Kim, Yeon-Sik
    • Nuclear Engineering and Technology
    • /
    • 제44권6호
    • /
    • pp.561-586
    • /
    • 2012
  • This paper describes a summary of final prediction results by system-scale safety analysis codes during the OECD/NEA/CSNI ISP-50 exercise, targeting a 50% Direct Vessel Injection (DVI) line break integral effect test performed with the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS). This ISP-50 exercise has been performed in two consecutive phases: "blind" and "open" phases. Quantitative comparisons were performed using the Fast Fourier Transform Based Method (FFTBM) to compare the overall accuracy of the collected calculations. Great user effects resulting from the combination of the possible reasons were found in the blind phase, confirming that user effect is still one of the major issues in connection with the system thermal-hydraulic code application. Open calculations showed better prediction accuracy than the blind calculations in terms of average amplitude (AA) value. A total of nineteen organizations from eleven countries participated in this ISP-50 program and eight leading thermal-hydraulic system analysis codes were used: APROS, ATHLET, CATHARE, KORSAR, MARS-KS, RELAP5/MOD3.3, TECH-M-97, and TRACE.

Development of Motion Control Camera Design Based on Wires with Anti-sway Method

  • Kim, Tae-Rim;Jung, Sung-Young;Baek, Gyeong-Dong;Kim, Sung-Shin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제10권1호
    • /
    • pp.25-30
    • /
    • 2010
  • This paper is proposed about three axis motion control camera design method based on wires. Original motion control camera consists of track, boom, L-Head, Camera and so on and is enormous and expensive. But proposed motion control camera adjusts wire length using encoders and motors. And position control use position based straight line of straight-line move method for moving precise position. Proposed simple design is able to use various place and inexpensive than original motion control camera. But, camera was vibrated and rotated due to basic property of wire. So we proposed solutions that connected method of wire and using a tensional object for reducing rotation. For proposed algorithm verification, we realized three axis motion control camera based on wire and measured oscillation while moving same trace. We confirmed the results that standard deviation of oscillation was reduced 4.93 degree than before design method.

태양광 발전시스템을 위한 단상 PWM 전압형 인버터 (A Single-phase PWM Voltage Source Inverter for Photovoltaic Generation System)

  • 유택빈;성낙규;강승욱;이승환;이훈구;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.443-445
    • /
    • 1995
  • Since the residential load is an AC load, while the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell and must provide the sinusoidal wave current and voltage with unity power factor in the case of driving to Interact with utility line. It is always necessary for the output of solar cell to operate in the vicinity of maximum power point, since it is greatly fluctuated by insolation. This paper treats that we will constitute a single phase PWM voltage source inverter and trace the modulation index which always maximize the output of solar cell in propotion to insolation variation and prove it by simulation that we can provide current wave, which is nearly sinusoidal wave with unity power factor, for load and utility line.

  • PDF