• Title/Summary/Keyword: Line Heating

Search Result 378, Processing Time 0.024 seconds

Feasibility Study on Thermal Power Plant Condenser Heat Recovery for District Heating and Fuel Line Preheating (발전소 복수기 배열회수의 지역난방 및 연료라인 예열용 활용타당성 검토)

  • Jung, Hoon;Hwang, Gwang-Won
    • New & Renewable Energy
    • /
    • v.5 no.3
    • /
    • pp.40-48
    • /
    • 2009
  • Recovered heat has been considered as a renewable energy in Europe since 2008 because its great effect on energy saving and carbon decreasing in plant process. Energy saving and decreasing green gas are critical issue today, so various technologies to save energy and decrease carbon dioxide in plant process have been applied to many industrial area. In this paper, the feasibility of condenser heat recovery by heat pump in power plant for district heating and fuel line preheating were reviewed by verifying energy (heat) balance and mass balance of power plant model. Some ways to compose proper system to recover heat of condenser are suggested and their possibilities are also reviewed. Limitations on heat recovery in power plant are also reviewed. The results are verified by calculating input/output energy based on actual performance test data of Taean Thermal Power Plant in Korea. There is noticeable improvement of plant performance in some cases which demand low temperature (<100 C) heat like distrcit heating, fuel line heating, and so forth.

  • PDF

Effects of Line Heating Variables for forming the Curved Plate on the Behavior of Distortion (곡가공을 위한 선상 가열 특성에 따른 변형 거동에 관한 연구)

  • Sin, Sang-Beom;Lee, Dong-Ju;Kim, Gyeong-Gyu;Yun, Jung-Geun
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.291-293
    • /
    • 2005
  • The purpose of this study is to evaluate the effects of line heating variables for forming the curved plate on the behavior of distortion using FEA and experiment. The optimum mixed ratio and standoff for flame heating was established under the heating conditions given in this study. With the heating condition, the predictive equation of angular distortion and transverse shrinkage was established using FEA and verified by comparing the predicted results and experimental results.

  • PDF

A Study on the In-line Assessment of Completion for Fabrication of Curved Plates(I) (곡판 가공의 인라인 완성도 평가에 관한 연구(I))

  • Jung, Jae-Min;Park, Chi-Mo;Yang, Park-Dal-Chi
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.135-139
    • /
    • 2009
  • In the line heating for the plate forming of a ship's hull, an in line assessment of completion is necessary for an automated production system. In the current curved plate forming process, a fabricated plate is compared to a template that is made in the mold loft and is used for the determination of the heating line for the next step. In this paper, a new method is presented for the in line assessment of completion for curved plate forming. This method uses a 3-D scanner. For the registration of the scanned data for a surface and the target surface, the ICP (Iterative Closest Points) method was adopted. A computer program was developed to carry out the registration, check for similarities, visualize the surface, and control the results. This program was applied to a sample curved plate forming process.

A Study on the Variation of Physical Properties of Line-heated for Type-B LNG Fuel Tank with 9% Nickel Steel Plate (9% Nickel강이 적용된 Type-B LNG 연료탱크 선상가열의 물성 변화에 관한 연구)

  • Choi, Kyung-Shin;Lee, Ji-Han;Hong, Ji-Ung;Chung, Won-Jee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.7
    • /
    • pp.89-97
    • /
    • 2020
  • Container vessels continue to grow in size, led by global shipowner. Large ships can be loaded more cargo at a time, reducing the cost of transportation per teu. this eventually leads to economies of sale, in which the production cost per unit decreases with increasing output. in accordance with the 70th Convention of the Marine Environment Protection Committee of the International Maritime Organization, as of January 1, 2020, MARPOL Annex VI Regulation 14.1.3 will be effective. All vessels must be meet these criteria to reduce Sox emissions and reduce NOx emissions by reducing the content of manned sulfur oxides from 3.5% to less than 0.5%, otherwise IACS Member States Entry to the port is denied. in order to do that need to LNG storage tank. in this study characteristic of the material after line heating (600℃,700℃,800℃,900℃) of 9% Ni steel used in the manufacture of LNG fuel tank of ship were verified using by mechanical test. In the heating method by line heating. The initial properties of steel are changed by variables such as temperature, time, speed. The experimental data of line heating presented in this paper confirmed that the initial change of 9% Ni steel could be minimized.

Determination of Inherent Strain Regions to Estimate Plate Deformation by Line Heating (선상가열 판변형 해석을 위한 고유변형도 영역의 결정법)

  • Chang-Doo Jang;Yun-Sok Yun;Dae-Eun Ko;Sung-Choon Moon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.1
    • /
    • pp.82-89
    • /
    • 2002
  • The inherent strain method is known to be very effective in predicting the plate deformation by line heating. Traditionally the inherent strain regions have been determined from the temperature distribution and the phase transformation regions(Ac3) of welding experiments. Since the phenomena of line heating are similar to those of welding, the experimental results under the same welding conditions have been applied directly to line heating analysis. The results cannot, however, reflect the effect of heating pattern and plate thickness. Besides, water-cooling in the actual heating process can alter the steel's phase to martensite and shear plastic deformation occurs during the transformation. In this study, the experimental measurement of temperature distribution was substituted with a transient heat transfer analysis using FEM so that we could obtain the temperature distribution according to heat flux models of the heating pass. In order to consider plastic strains occurring additionally under phase transformation, inherent strain regions were assumed to be limited to the eutectoid temperature(Ac1). Using the regions, plate deformations could be predicted to validate our method and the results were in good agreement with the experimental ones

On-Chip Process and Characterization of the Hermetic MEMS Packaging Using a Closed AuSn Solder-Loop (사각고리형상의 AuSn 합금박막을 이용한 MEMS 밀봉 패키징 및 특성 시험)

  • Seo, Young-Ho;Kim, Seong-A;Cho, Young-Ho;Kim, Geun-Ho;Bu, Jong-Uk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.435-442
    • /
    • 2004
  • This paper presents a hermetic MEMS on-chip package bonded by a closed-loop AuSn solder-line. We design three different package specimens, including a substrate heated specimen without interconnection-line (SHX), a substrate heated specimen with interconnection-line (SHI) and a locally heated specimen with interconnection-line (LHI). Pressurized helium leak test has been carried out for hermetic seal evaluation in addition to the critical pressure test for bonding strength measurement. Substrate heating method (SHX, SHI) requires the bonding time of 40min. at 400min, while local heating method (LHI) requires 4 min. at the heating power of 6.76W. In the hermetic seal test. SHX, SHI and LHI show the leak rates of 5.4$\pm$6.7${\times}$$^{-10}$ mbar-l/s, 13.5$\pm$9.8${\times}$$^{-10}$ mbar-l/s and 18.5$\pm$9.9${\times}$$^{-10}$ mbar-l/s, respectively, for an identical package chamber volume of 6.89$\pm$0.2${\times}$$^{-10}$. In the critical pressure test, no fracture is found in the bonded specimens up to the applied pressure of 1$\pm$0.1MPa, resulting in the minimum bonding strength of 3.53$\pm$0.07MPa. We find that the present on-chip packaging using a closed AuSn solder-line shows strong potential for hermetic MEMS packaging with interconnection-line due to the hermetic seal performance and the shorter bonding time for mass production.

Tip-less PDP Vacuum In-Line Sealing Technology by Bubble-Reduced Frit along an Auxiliary Heating Line

  • Kwon, Sang-Jik;Yang, Hwi-Chan;Lee, Myung-Sik;Whang, Ki-Woong;Jung, Dong-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.643-646
    • /
    • 2002
  • Sealing of two glass plates composing of PDP panel was done in a vacuum chamber by using an auxiliary heating line(AHL). In order to improve the uniformity of sealing temperature and reduce the panel temperature during sealing, the AHL was introduced by a screen printing method inside a frit glass and used as a part of heating source for the frit melting. By using the AHL technology and the specially prepared frit glass, we have successfully sealed a PDP test panel without bubbles and any leak through the frit glass.

  • PDF

Deformation by line heating for thin plate (박판 곡직을 위한 선 가열 시 변형 특성에 관한 연구)

  • Park, Jung-Gu;Jang, Gyeong-Bok;Jo, Si-Hun;Jang, Tae-Won
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.282-284
    • /
    • 2005
  • The line heating methods is very widely employed to correct deformation of thin plate structures. In this study, evaluation was carried out on the temperature distribution of line heating methods using FEA and practical experiments. In FEA, heat input model was established using Tsuji's double Gaussian heat input mode. This model was verified by comparing with experimental data. Thermo elasto-plastic analysis was performed using commercial FE code, MSC/MARC. Transverse shrinkage and angular distortion were measured using 3D measuring apparatus. Based on these results, a simplified analysis method is applied by using equivalent loading method.

  • PDF

A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC) (전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구)

  • 신관우;김용태;이윤섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.8
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

Numerical Control System for the Automation of Steel Plate Forming (강판의 곡가공 자동화를 위한 수치제어 시스템)

  • Lee, Joo-Sung;Shin, Sung-Min
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.318-322
    • /
    • 2002
  • In this paper the automatic plate forming system developed by the present research group is introduced, which would be helpful for other researchers. The present system consists of three parts : heating line information generation software, automatic heating apparatus and numerical control system. The numerical control system developed by the present authors is detailed. Performance test for the developed system has been carried out and good results has been obtained. As an extension of the present study, the present automatic plate fanning system will be applied to surfaces found in ship and offshore structure.

  • PDF