• 제목/요약/키워드: Limit Resolution

검색결과 281건 처리시간 0.031초

의료분쟁의 법적책임과 ADR제도의 효율적 운영방안 (A Study on Legal Liability and Efficient Planning for Alternative Dispute Resolution in Medical Disputes)

  • 남선모
    • 한국중재학회지:중재연구
    • /
    • 제26권4호
    • /
    • pp.129-149
    • /
    • 2016
  • Medical dispute means the dispute between the hospital and the patient due to a medical accident. In general, medical accidents must be in accordance with the terms that are used in the medical dispute adjustment method stated in Article 2 (definition). In relation to this, there is a need to discuss an efficient operation scheme for Alternative Dispute Resolution (ADR) in medical disputes. In addition, it is necessary to look at issues of civil liability and criminal liability. In particular, in the consumer dispute arbitration committee, there is a case to make a "decision not to adjust" in aggressive intervention in the process of conflict resolution. The medical staff, on the basis of its "decision," can use this as a proven material for civil and criminal cases. This is rather upon the determination of the consumer council as a typical side effect to defend the user's perspective. This is the "decision" as was expressed from an order, "not adjusted." It is also determined to be easy and clearly timely. In the medical litigation, it is requesting the burden of proof of a patient's cause-and-effect relationship with the doctors committing negligence and medical malpractice. This seems to require the promotion of legislation in the direction to reduce future cases. It is determined that the burden of proof of medical accidents must be improved. The institution receiving the medical accident should prevent a closure report. Further, it is necessary to limit the transition to a franchise point. In this paper, we understand the problems of the current medical dispute resolution system, trying to establish a medical dispute resolution system desirable through an efficient alternative. In addition, it wants help in the protection and realization in medical consumers' and patients' rights. The relevant authorities will take advantage of these measures. After all, this could contribute to the system for a smooth resolution of a medical dispute.

Adjusting the Retry Limit for Congestion Control in an Overlapping Private BSS Environment

  • Park, Chang Yun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권6호
    • /
    • pp.1881-1900
    • /
    • 2014
  • Since 802.11 wireless LANs are so widely used, it has become common for numerous access points (APs) to overlap in a region, where most of those APs are managed individually without any coordinated control. This pattern of wireless LAN usage is called the private OBSS (Overlapping Basic Service Set) environment in this paper. Due to frame collisions across BSSs, each BSS in the private OBSS environment suffers severe performance degradation. This study approaches the problem from the perspective of congestion control rather than noise or collision resolution. The retry limit, one of the 802.11 attributes, could be used for traffic control in conjunction with TCP. Reducing the retry limit causes early discard of a frame, and it has a similar effect of random early drops at a router, well known in the research area of congestion control. It makes the shared link less crowded with frames, and then the benefit of fewer collisions surpasses the penalty of less strict error recovery. As a result, the network-wide performance improves and so does the performance of each BSS eventually. Reducing the retry limit also has positive effects of merging TCP ACKs and reducing HOL-like blocking time at the AP. Extensive experiments have validated the idea that in the OBSS environment, reducing the retry limit provides better performance, which is contrary to the common wisdom. Since our strategy is basically to sacrifice error recovery for congestion control, it could yield side-effects in an environment where the cost of error recovery is high. Therefore, to be useful in general network and traffic environments, adaptability is required. To prove the feasibility of the adaptive scheme, a simple method to dynamically adjust the value of the retry limit has been proposed. Experiments have shown that this approach could provide comparable performance in unfriendly environments.

대역 확산 신호를 위한 고유치 해석 기반의 초 분해능 지연 시간 추정 알고리즘 (Eigen-Analysis Based Super-Resolution Time Delay Estimation Algorithms for Spread Spectrum Signals)

  • 박형래;신준호
    • 한국통신학회논문지
    • /
    • 제38A권12호
    • /
    • pp.1013-1020
    • /
    • 2013
  • 본 논문에서는 대역 확산 신호를 위한 고유치 해석 기반의 초 분해능 지연 시간 추정(super-resolution time delay estimation) 알고리즘을 개발하고 각 알고리즘의 성능을 비교, 분석한다. 먼저, 고유치 해석 기반의 대표적인 도래각 추정 알고리즘인 MUSIC, ESPRIT, Minimum-Norm을 이용하여 초 분해능 지연 시간 추정 알고리즘을 개발하고 직접 대역확산 방식의 ISO/IEC 24730-2.1 실시간 위치 추적 시스템 (real-time locating system: RTLS)에 적용하여 RTLS 환경에서 각 알고리즘의 성능을 시뮬레이션을 통해 비교, 분석한다. 시뮬레이션 결과로부터 세 알고리즘 모두 레일리이 분해능 한계 이내로 수신되는 다중 신호의 지연 시간을 모두 분리, 추정함을 알 수 있었다. 그러나, RTLS 환경에서는 MUSIC과 Minimum-Norm의 성능은 서로 비슷하나 ESPRIT은 두 알고리즘에 비해 성능이 현격히 저하됨을 알 수 있다.

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-phase High Performance Liquid Chromatography after Derivatization with (S)-(-)-${\alpha}$-methylbenzyl isocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun;Kwon, Young-Hee;Sohn, Young-Teak
    • Archives of Pharmacal Research
    • /
    • 제20권5호
    • /
    • pp.486-490
    • /
    • 1997
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with (S)-(-)-${\alpha}$-methyl-benzyl isocyanate, the diastereomeric derivatives were resolved $(R_s=1.59)$ on $5{\mu}M$ octadecylsilan column using 47% methanol as a mobile phase with fluorescence detection. The detection limit of each enantiomer was 10 ng/ml (S/N=3).

  • PDF

카메라 영상을 이용한 진동변위 측정 (A Technique for Measuring Vibration Displacement Using Camera Image)

  • 손기성;전형섭;박진호;박종원
    • 한국소음진동공학회논문집
    • /
    • 제23권9호
    • /
    • pp.789-796
    • /
    • 2013
  • Vibration measurements using image processing have been studied by many researchers as it can remotely measure vibration displacements at multiple points simultaneously. It is difficult, however, to obtain accurate displacement from the measured image signals because the resolution of image data is dependent on camera performance and normally lower than that of vibration transducer directly measured. This paper suggests the enhanced technique for vibration displacement measurement by applying the expected value of edge probability distribution to the varying pixel points in the image. The method can both increase the resolution limit of camera image and decrease the measurement errors. The working performance of the proposed technique is verified applying to the vibration measurement of a rotating machine.

Large Area Bernal Stacked Bilayer Graphene Grown by Multi Heating Zone Low Pressure Chemical Vapor Deposition

  • Han, Jaehyun;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.239.2-239.2
    • /
    • 2015
  • Graphene is a most interesting material due to its unique and outstanding properties. However, semi-metallic properties of graphene along with zero bandgap energy structure limit further application to optoelectronic devices. Recently, many researchers have shown that band gap can be induced in the Bernal stacked bilayer graphene. Several methods have been used for the controlled growth of the Bernal staked bilayer graphene, but it is still challenging to control the growth process. In this paper, we synthesize the large area Bernal stacked bilayer graphene using multi heating zone low pressure chemical vapor deposition (LPCVD). The synthesized bilayer graphenes are characterized by Raman spectroscopy, optical microscope (OM), scanning electron microscopy (SEM). High resolution transmission electron microscopy (HRTEM) is used for the observation of atomic resolution image of the graphene layers.

  • PDF

Infrared Scanning Near-Field Optical Microscopy (IR-SNOM) Below the Diffraction Limit

  • Sanghera, J.S.;Aggarwal, I.D.;Cricenti, A.;Generossi, R.;Luce, M.;Perfetti, P.;Margoritondo, G.;Tolk, N.;Piston, D.
    • 세라미스트
    • /
    • 제10권3호
    • /
    • pp.55-66
    • /
    • 2007
  • Infrared Scanning Near-field Optical Microscopy (IR-SNOM) is an extremely powerful analytical instrument since it combines IR spectroscopy's high chemical specificity with SNOM's high spatial resolution. In order to do this in the infrared, specialty chalcogenide glass fibers were fabricated and their ends tapered to generate SNOM probes. The fiber tips were installed in a modified near field microscope and both inorganic and biological samples illuminated with the tunable output from a free-electron laser located at Vanderbilt University. Both topographical and IR spectral images were simultaneously recorded with a resolution of ${\sim}50\;nm$ and ${\sim}100\;nm$, respectively. Unique spectroscopic features were identified in all samples, with spectral images exhibiting resolutions of up to ${\lambda}/60$, or at least 30 times better than the diffraction limited lens-based microscopes. We believe that IR-SNOM can provide a very powerful insight into some of the most important bio-medical research topics.

  • PDF

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-Phase High Performance Liquid Chromatography after Derivatization with 2,3,4,6-Tetra-O-acetyl-${\beta}$-D-glucopyranosyl Isothiocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun
    • Archives of Pharmacal Research
    • /
    • 제21권2호
    • /
    • pp.217-222
    • /
    • 1998
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with 2,3,4,6-tetra-O-acetyl-$\beta$-D-glucopyranosyl isothiocyanate, the diastereomeric derivatives were resolved (Rs=1.83) on $5{\mu}m$ octadecylsilan column using 35% acetonitrile in 0.05M ammonium acetate buffer (pH=6) as a mobile phase with electrochemical detection. The diastereomeric derivatives were formed within 30 min. The detection limit of each enantiomer was 20 ng/ml (S/N=3).

  • PDF

오차 최소화된 정밀 광삼각법 프로브의 해석 및 설계 (Design & Analysis of an Error-reduced Precision Optical Triangulation Probes)

  • 김경찬;오세백;김종안;김수현;곽윤근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.411-414
    • /
    • 2000
  • Optical Triangulation Probes (OTPs) are widely used for their simple structure. high resolution, and long operating range. However, errors originating from speckle, inclination of the object, source power fluctuation, ambient light, and noise of the detector limit their usability. In this paper, we propose new design criteria for an error-reduced OTP. The light source module for the system consists of an incoherent light source and a multimode optical fiber for eliminating speckle and shaping a Gaussian beam Intensity profile. A diffuse-reflective white copy paper, which is attached to the object, makes the light intensity distribution on the change-coupled device(CCD). Since the peak positions of the intensity distribution are not related to the various error sources, a sub-pixel resolution signal processing algorithm that can detect the peak position makes it possible to construct an error-reduced OTP system

  • PDF

Assessing the Nano-Dynamics of the Cell Surface

  • Bae, Chil-Man;Park, Ik-Keun;Butler, Peter J.
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.263-268
    • /
    • 2012
  • It is important to know the mechanism of cell membrane fluctuation because it can be readout for the nanomechanical interaction between cytoskeleton and plasma membrane. Traditional techniques, however, have drawbacks such as probe contact with the cell surface, complicate analysis, and limit spatial and temporal resolution. In this study, we developed a new system for non-contact measurement of nano-scale localized-cell surface dynamics using modified-scanning ion-conductance microscopy. With 2 nm resolution, we determined that endothelial cells have local membrane fluctuations of ~20 nm, actin depolymerization causes increase in fluctuation amplitude, and ATP depletion abolishes all membrane fluctuations.