• Title/Summary/Keyword: Limit Resolution

Search Result 280, Processing Time 0.026 seconds

Adjusting the Retry Limit for Congestion Control in an Overlapping Private BSS Environment

  • Park, Chang Yun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.6
    • /
    • pp.1881-1900
    • /
    • 2014
  • Since 802.11 wireless LANs are so widely used, it has become common for numerous access points (APs) to overlap in a region, where most of those APs are managed individually without any coordinated control. This pattern of wireless LAN usage is called the private OBSS (Overlapping Basic Service Set) environment in this paper. Due to frame collisions across BSSs, each BSS in the private OBSS environment suffers severe performance degradation. This study approaches the problem from the perspective of congestion control rather than noise or collision resolution. The retry limit, one of the 802.11 attributes, could be used for traffic control in conjunction with TCP. Reducing the retry limit causes early discard of a frame, and it has a similar effect of random early drops at a router, well known in the research area of congestion control. It makes the shared link less crowded with frames, and then the benefit of fewer collisions surpasses the penalty of less strict error recovery. As a result, the network-wide performance improves and so does the performance of each BSS eventually. Reducing the retry limit also has positive effects of merging TCP ACKs and reducing HOL-like blocking time at the AP. Extensive experiments have validated the idea that in the OBSS environment, reducing the retry limit provides better performance, which is contrary to the common wisdom. Since our strategy is basically to sacrifice error recovery for congestion control, it could yield side-effects in an environment where the cost of error recovery is high. Therefore, to be useful in general network and traffic environments, adaptability is required. To prove the feasibility of the adaptive scheme, a simple method to dynamically adjust the value of the retry limit has been proposed. Experiments have shown that this approach could provide comparable performance in unfriendly environments.

Eigen-Analysis Based Super-Resolution Time Delay Estimation Algorithms for Spread Spectrum Signals (대역 확산 신호를 위한 고유치 해석 기반의 초 분해능 지연 시간 추정 알고리즘)

  • Park, Hyung-Rae;Shin, Joon-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.12
    • /
    • pp.1013-1020
    • /
    • 2013
  • In this paper the super-resolution time delay estimation algorithms based on eigen-analysis are developed for spread spectrum signals along with their comparative performance analysis. First, we shall develop super-resolution time delay estimation algorithms using the representative eigen-analysis based AOA (angle-of-arrival) estimation algorithms such as MUSIC, Minimum-Norm, and ESPRIT, and apply them to the ISO/IEC 24730-2.1 real-time locating system (RTLS) employing a direct sequence spread spectrum (DS-SS) technique to compare their performances in RTLS environments. Simulation results illustrate that all the three algorithms can resolve multipath signals whose delay differences are even smaller than the Rayleigh resolution limit. Simulation results also show that MUSIC and Minimum-Norm provide a similar performance while ESPRIT is inferior to both algorithms in RTLS environments.

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-phase High Performance Liquid Chromatography after Derivatization with (S)-(-)-${\alpha}$-methylbenzyl isocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun;Kwon, Young-Hee;Sohn, Young-Teak
    • Archives of Pharmacal Research
    • /
    • v.20 no.5
    • /
    • pp.486-490
    • /
    • 1997
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with (S)-(-)-${\alpha}$-methyl-benzyl isocyanate, the diastereomeric derivatives were resolved $(R_s=1.59)$ on $5{\mu}M$ octadecylsilan column using 47% methanol as a mobile phase with fluorescence detection. The detection limit of each enantiomer was 10 ng/ml (S/N=3).

  • PDF

A Technique for Measuring Vibration Displacement Using Camera Image (카메라 영상을 이용한 진동변위 측정)

  • Son, Ki-Sung;Jeon, Hyeong-Seop;Park, Jin-Ho;Park, Jong Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.9
    • /
    • pp.789-796
    • /
    • 2013
  • Vibration measurements using image processing have been studied by many researchers as it can remotely measure vibration displacements at multiple points simultaneously. It is difficult, however, to obtain accurate displacement from the measured image signals because the resolution of image data is dependent on camera performance and normally lower than that of vibration transducer directly measured. This paper suggests the enhanced technique for vibration displacement measurement by applying the expected value of edge probability distribution to the varying pixel points in the image. The method can both increase the resolution limit of camera image and decrease the measurement errors. The working performance of the proposed technique is verified applying to the vibration measurement of a rotating machine.

Large Area Bernal Stacked Bilayer Graphene Grown by Multi Heating Zone Low Pressure Chemical Vapor Deposition

  • Han, Jaehyun;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.239.2-239.2
    • /
    • 2015
  • Graphene is a most interesting material due to its unique and outstanding properties. However, semi-metallic properties of graphene along with zero bandgap energy structure limit further application to optoelectronic devices. Recently, many researchers have shown that band gap can be induced in the Bernal stacked bilayer graphene. Several methods have been used for the controlled growth of the Bernal staked bilayer graphene, but it is still challenging to control the growth process. In this paper, we synthesize the large area Bernal stacked bilayer graphene using multi heating zone low pressure chemical vapor deposition (LPCVD). The synthesized bilayer graphenes are characterized by Raman spectroscopy, optical microscope (OM), scanning electron microscopy (SEM). High resolution transmission electron microscopy (HRTEM) is used for the observation of atomic resolution image of the graphene layers.

  • PDF

Infrared Scanning Near-Field Optical Microscopy (IR-SNOM) Below the Diffraction Limit

  • Sanghera, J.S.;Aggarwal, I.D.;Cricenti, A.;Generossi, R.;Luce, M.;Perfetti, P.;Margoritondo, G.;Tolk, N.;Piston, D.
    • Ceramist
    • /
    • v.10 no.3
    • /
    • pp.55-66
    • /
    • 2007
  • Infrared Scanning Near-field Optical Microscopy (IR-SNOM) is an extremely powerful analytical instrument since it combines IR spectroscopy's high chemical specificity with SNOM's high spatial resolution. In order to do this in the infrared, specialty chalcogenide glass fibers were fabricated and their ends tapered to generate SNOM probes. The fiber tips were installed in a modified near field microscope and both inorganic and biological samples illuminated with the tunable output from a free-electron laser located at Vanderbilt University. Both topographical and IR spectral images were simultaneously recorded with a resolution of ${\sim}50\;nm$ and ${\sim}100\;nm$, respectively. Unique spectroscopic features were identified in all samples, with spectral images exhibiting resolutions of up to ${\lambda}/60$, or at least 30 times better than the diffraction limited lens-based microscopes. We believe that IR-SNOM can provide a very powerful insight into some of the most important bio-medical research topics.

  • PDF

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-Phase High Performance Liquid Chromatography after Derivatization with 2,3,4,6-Tetra-O-acetyl-${\beta}$-D-glucopyranosyl Isothiocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun
    • Archives of Pharmacal Research
    • /
    • v.21 no.2
    • /
    • pp.217-222
    • /
    • 1998
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with 2,3,4,6-tetra-O-acetyl-$\beta$-D-glucopyranosyl isothiocyanate, the diastereomeric derivatives were resolved (Rs=1.83) on $5{\mu}m$ octadecylsilan column using 35% acetonitrile in 0.05M ammonium acetate buffer (pH=6) as a mobile phase with electrochemical detection. The diastereomeric derivatives were formed within 30 min. The detection limit of each enantiomer was 20 ng/ml (S/N=3).

  • PDF

Design & Analysis of an Error-reduced Precision Optical Triangulation Probes (오차 최소화된 정밀 광삼각법 프로브의 해석 및 설계)

  • Kim, Kyung-Chan;Oh, Se-Baek;Kim, Jong-Ahn;Kim, Soo-Hyun;Kwak, Yoon-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.411-414
    • /
    • 2000
  • Optical Triangulation Probes (OTPs) are widely used for their simple structure. high resolution, and long operating range. However, errors originating from speckle, inclination of the object, source power fluctuation, ambient light, and noise of the detector limit their usability. In this paper, we propose new design criteria for an error-reduced OTP. The light source module for the system consists of an incoherent light source and a multimode optical fiber for eliminating speckle and shaping a Gaussian beam Intensity profile. A diffuse-reflective white copy paper, which is attached to the object, makes the light intensity distribution on the change-coupled device(CCD). Since the peak positions of the intensity distribution are not related to the various error sources, a sub-pixel resolution signal processing algorithm that can detect the peak position makes it possible to construct an error-reduced OTP system

  • PDF

Assessing the Nano-Dynamics of the Cell Surface

  • Bae, Chil-Man;Park, Ik-Keun;Butler, Peter J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.263-268
    • /
    • 2012
  • It is important to know the mechanism of cell membrane fluctuation because it can be readout for the nanomechanical interaction between cytoskeleton and plasma membrane. Traditional techniques, however, have drawbacks such as probe contact with the cell surface, complicate analysis, and limit spatial and temporal resolution. In this study, we developed a new system for non-contact measurement of nano-scale localized-cell surface dynamics using modified-scanning ion-conductance microscopy. With 2 nm resolution, we determined that endothelial cells have local membrane fluctuations of ~20 nm, actin depolymerization causes increase in fluctuation amplitude, and ATP depletion abolishes all membrane fluctuations.

A Study of Sub-Pixel Detection for Hyperspectral Image Using Linear Spectral Unmixing Algorithm (Linear Spectral Unmixing 기법을 이용한 하이퍼스펙트럴 영상의 Sub-Pixel Detection에 관한 연구)

  • 김대성;조영욱;한동엽;김용일
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.161-166
    • /
    • 2003
  • Hyperspectral imagery have high spectral resolution and provide the potential for more accurate and detailed information extraction than any other type of remotely sensed data. In this paper, the "Linear Spectral Unmixing" model which is one solution to overcome the limit of spatial resolution for remote sensing data was introduced and we applied the algorithm to hyperspectral image. The result was not good because of some problems such as image calibration and used endmembers. Therefore, we analyzed the cause and had a search for a solution.

  • PDF