• Title/Summary/Keyword: Likelihood Ratio Test

Search Result 290, Processing Time 0.023 seconds

Hybrid Statistical Learning Model for Intrusion Detection of Networks (네트워크 침입 탐지를 위한 변형된 통계적 학습 모형)

  • Jun, Sung-Hae
    • The KIPS Transactions:PartC
    • /
    • v.10C no.6
    • /
    • pp.705-710
    • /
    • 2003
  • Recently, most interchanges of information have been performed in the internet environments. So, the technuque, which is used as intrusion deleting tool for system protecting against attack, is very important. But, the skills of intrusion detection are newer and more delicate, we need preparations for defending from these attacks. Currently, lots of intrusion detection systemsmake the midel of intrusion detection rule using experienced data, based on this model they have the strategy of defence against attacks. This is not efficient for defense from new attack. In this paper, a new model of intrusion detection is proposed. This is hybrid statistical learning model using likelihood ratio test and statistical learning theory, then this model can detect a new attack as well as experienced attacks. This strategy performs intrusion detection according to make a model by finding abnomal attacks. Using KDD Cup-99 task data, we can know that the proposed model has a good result of intrusion detection.

Predictors of discogenic pain in magnetic resonance imaging: a retrospective study of provocative discography performed by posterolateral approach

  • Jain, Anuj;Jain, Suruchi;Barasker, Swapnil Kumar;Agrawal, Amit
    • The Korean Journal of Pain
    • /
    • v.34 no.4
    • /
    • pp.447-453
    • /
    • 2021
  • Background: Provocative discography (PD) is a test that is useful in diagnosing discogenic pain (DP). In this study, to diagnose DP, we used a posterolateral approach of needle placement and followed pressure criteria laid down by the Spine Intervention Society. The aim was to identify the correlation between magnetic resonance imaging (MRI) findings (desiccation, high intensity zone and change in shape and size of the disc) and the results of PD. Methods: Records of 50 patients who underwent PD for DP were analyzed. A total of 109 PDs were performed, with 54 suspect and 55 control discs. Alternate pain generators were ruled out. Results: A total of 35 suspect discs were positive on PD. The mean disc pressure in the suspect disc was 31.9 ± 7.9 psi (range, 15-44). Of the 50 patients who underwent PD, 35 had positive MRI findings. A significant positive correlation was found only between disc desiccation and discography result (r = 0.6, P < 0.001). Logistic regression analysis revealed that only desiccation successfully predicted the result of discography (OR = 26.5, P < 0.001); a high intensity zone and a disc protrusion/extrusion had an OR 2.3 and 1.24, respectively. Disc desiccation of Pfirmann grade 3 or more had a sensitivity and specificity of 0.93 and 0.64 respectively in identifying painful discs; the positive likelihood ratio was 2.58 while the negative likelihood ratio was 0.11. Conclusions: In patients with DP, disc desiccation is the most useful MRI feature that predicts a painful disc on PD.

Genetic parameter estimation for milk β-hydroxybutyrate and acetone in early lactation and its association with fat to protein ratio and energy balance in Korean Holstein cattle

  • Ranaraja, Umanthi;Cho, KwangHyun;Park, MiNa;Kim, SiDong;Lee, SeokHyun;Do, ChangHee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.6
    • /
    • pp.798-803
    • /
    • 2018
  • Objective: The objective of this study was to estimate the genetic parameters for milk ${\beta}$-hydroxybutyrate (BHBA), acetone (Ac), fat protein ratio (FPR), and energy balance (EB) using milk test day records and investigate the effect of early lactation FPR and EB on milk ketone body concentrations. Methods: Total 262,940 test-day records collected from Korea Animal Improvement Association during the period of 2012 to 2016 were used in this study. BHBA and Ac concentrations in milk were measured by Fourier transform infrared spectroscopy (FTIR). FPR values were obtained using test day records of fat and protein percentage. EB was calculated using previously developed equation based on parity, lactation week, and milk composition data. Genetic parameters were estimated by restricted maximum likelihood procedure based on repeatability model using Wombat program. Results: Elevated milk BHBA and Ac concentrations were observed during the early lactation under the negative energy balance. Milk FPR tends to decrease with the decreasing ketone body concentrations. Heritability estimates for milk BHBA, Ac, EB, and FPR ranged from 0.09 to 0.14, 0.23 to 0.31, 0.19 to 0.52, and 0.16 to 0.42 respectively at parity 1, 2, 3, and 4. The overall heritability for BHBA, Ac, EB and FPR were 0.29, 0.32, 0.58, and 0.38 respectively. A common pattern was observed in heritability of EB and FPR along with parities. Conclusion: FPR and EB can be suggested as potential predictors for risk of hyperketonemia. The heritability estimates of milk BHBA, Ac, EB, and FPR indicate that the selective breeding may contribute to maintaining the milk ketone bodies at optimum level during early lactation.

Reliability and Validity of the Alcohol Use Disorders Identification Test - Consumption in Screening for Adults with Alcohol Use Disorders and Risky Drinking In Japan

  • Osaki, Yoneatsu;Ino, Aro;Matsushita, Sachio;Higuchi, Susumu;Kondo, Yoko;Kinjo, Aya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6571-6574
    • /
    • 2014
  • Background: Alcohol is well established as a risk factor for cancer development in many organ sites. To assess the reliability and validity of the Alcohol Use Disorders Identification Test - Consumption (AUDIT-C) for detecting alcohol use disorders or risky drinking in Japanese adults the present study was conducted. Materials and Methods: A test-retest method was applied with a 2-week interval with 113 health care employees. The k coefficient, Cronbach's coefficient alpha, Spearman's correlation coefficient, and intraclass correlation coefficient (ICC) were determined and the validity of the AUDIT-C was analyzed using the data from a nationwide survey on adult alcohol use conducted in 2008 (n=4,123). Results: The reliability of the AUDIT-C score was high (${\kappa}$ coefficient=0.63, Cronbach's alpha=0.98, correlation coefficient=0.95, and ICC=0.95). According to the likelihood ratio and Youden index, appropriate cutoffs for the AUDIT-C were ${\geq}5points$ in men and ${\geq}4$ points in women. The sensitivity and specificity of these cutoffs for identifying ${\geq}8$ points on the AUDIT were 0.88 and 0.80, respectively, for men (positive likelihood ratio [LR+]=4.5) and 0.96 and 0.87, respectively, for women (LR+=7.7). The sensitivity and specificity of the cutoffs for identifying ${\geq}12$ points on the AUDIT were 0.90 and 0.84, respectively, for men (LR+=5.8) and 0.93 and 0.94, respectively, for women (LR+=15.8). The sensitivity and specificity of the cutoffs for identifying ${\geq}16$ points on the AUDIT were 0.93 and 0.80, respectively, for men (LR+=4.7) and 0.92 and 0.98, respectively, for women (LR+=55.6). With higher scores on the AUDIT, the specificity decreased and false-positives increased. The appropriate cutoffs for identifying risky drinking were the same for both genders. Conclusions: The reliability and validity of the AUDIT-C are high, indicating that it is useful for identifying alcohol use disorders or risky drinking among the general population in Japan, a group at high risk of cancer development.

Clinical Evaluation of a Rapid Diagnostic Test Kit for Canine Parvovirus and Coronavirus (개 파보바이러스와 코로나바이러스 진단을 위한 신속진단키트의 임상적 유용성)

  • Chaeyeong MIN;Won-Shik KIM;Chom-Kyu CHONG;Yong LIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.1
    • /
    • pp.45-51
    • /
    • 2023
  • Canine parvovirus type 2 (CPV-2) and canine coronavirus (CCoV) are major pathogens that can induce gastroenteritis in dogs. They are highly contagious and have a high morbidity rate. There are no specific treatments available for them to date. Therefore, rapid and accurate diagnosis becomes essential. The rapid diagnostic test (RDT) for animals can be used widely in the field because it is fast and easy to use for diagnosis. Thus, this study aimed to clinically evaluate and confirm the clinical utility of CPV-2/CCoV RDT. The parameters evaluated included the limit of detection (LoD), cross-reactivity, interference, sensitivity, specificity, negative likelihood ratio (NLR), and kappa value. The results revealed that the LoD values for CPV-2 and CCoV were 9.7×10 50% tissue culture infectious dose (TCID50)/mL and 2.5×102 TCID50/mL, respectively. There was no cross-reactivity with nine pathogens or interference by interfering materials. The RDT showed a sensitivity of 90.0%, a specificity of 100.0%, NLR of 0.1, and a kappa value of 0.90 for diagnosing both viruses. In conclusion, CPV-2/CCoV RDT is useful as a screening test because of its high sensitivity, specificity, kappa value, and low NLR.

The Use of Confidence Interval of Measures of Diagnostic Accuracy (진단검사 정확도 평가지표의 신뢰구간)

  • Oh, Tae-Ho;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.319-323
    • /
    • 2015
  • The performance of diagnostic test accuracy is usually summarized by a variety of statistics such as sensitivity, specificity, predictive value, likelihood ratio, and kappa. These indices are most commonly presented when evaluations of competing diagnostic tests are reported, and it is of utmost importance to compare the accuracies of diagnostic tests to decide on the best available test for certain medical disorder. However, it is important to emphasize that specific point values of these indices are merely estimates. If parameter estimates are reported without a measure of uncertainty (precision), knowledgeable readers cannot know the range within which the true values of the indices are likely to lie. Therefore, when evaluations of diagnostic accuracy are reported the precision of estimates should be stated in parallel. To reflect the precision of any estimate of a diagnostic performance characteristic or of the difference between performance characteristics, the computation of confidential interval (CI), an indicator of precision, is widely used in medical literatures in that CIs are more informative to interpret test results than the simple point estimates. The majority of peer-reviewed journals usually require CIs to be specified for descriptive estimates, whereas domestic veterinary journals seem less vigilant on this issues. This paper describes how to calculate the indices and associated CIs using practical examples when assessing diagnostic test performance.

Cycle-life Test Time Reduction in Secondary Rechargeable Batteries by Combining Different Types of Acceleration (서로 다른 가속기법의 결합을 통한 2차 전지 사이클 시험 시간의 단축)

  • Park, Jong-In;Park, Jung-Won;Jung, Min-Ho;Huh, Yang-Hyun;Bae, Suk-Joo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.4
    • /
    • pp.153-161
    • /
    • 2008
  • 신뢰성 평가 시험은 종종 성능 평가에 장기간의 시간이 요구되며, 전체 생산비용까지 증가시키는 문제점을 안고 있다 스트레스를 이용한 가속수명시험은 제품의 신뢰성 고장과 밀접한 관련이 있는 고장 메커니즘의 촉진을 통해 고장에 이르는 기간을 단축함으로써 신뢰성 평가의 효율성을 도모할 수 있다. 본 연구에서는 이러한 스트레스 가속 시험에 빈도가속(Usage-Rate Acceleration) 또는 판정가속(Tightening Critical-Values) 등을 결합하여 한층 높은 가속효과를 도모하는 방법을 제안하고, 국내에서 생산되고 있는 2차 전지 제품에 대한 실제 시험 사례분석을 통해 결합된 가속방법의 효과를 실증적으로 보여주고 있다.

An Efficient Adaptive Polarimetric Processor with an Embedded CFAR

  • Park, Hyung-Rae;Kwag, Young-Kil;Wang, Hong
    • ETRI Journal
    • /
    • v.25 no.3
    • /
    • pp.171-178
    • /
    • 2003
  • To improve the detection performance of surveillance radars with polarization diversity, we developed an adaptive polarimetric processor and compared it with other polarimetric processors. We derived our adaptive polarimetric processor, called the polarization discontinuity detector (PDD), from the generalized likelihood ratio (GLR) test principle for the unspecified target component. We derived closed-form expressions of its probabilities of detection and false alarm, and compared its performance to that of the adaptive polarization canceller (APC) and Kelly's GLR processor. The PDD had a performance similar to Kelly's GLR in Gaussian clutter, and both the PDD and Kelly's GLR, which have embedded constant false alarm rates (CFARs), outperformed the APC, especially when the target polarization state was close to the clutter's polarization state. The important difference is that the PDD is much simpler than Kelly's GLR for hardware/software implementation, because the PDD does not require a costly two-parameter filter bank to cover the unknown target polarization state as Kelly's GLR does.

  • PDF

Cumulative Sum Control Charts for Simultaneously Monitoring Means and Variances of Multiple Quality Variables

  • Chang, Duk-Joon;Heo, Sunyeong
    • Journal of Integrative Natural Science
    • /
    • v.5 no.4
    • /
    • pp.246-252
    • /
    • 2012
  • Multivariate cumulative sum (CUSUM) control charts for simultaneously monitoring both means and variances under multivariate normal process are investigated. Performances of multivariate CUSUM schemes are evaluated for matched fixed sampling interval (FSI) and variable sampling interval (VSI) features in terms of average time to signal (ATS), average number of samples to signal (ANSS). Multivariate Shewhart charts are also considered to compare the properties of multivariate CUSUM charts. Numerical results show that presented CUSUM charts are more efficient than the corresponding Shewhart chart for small or moderate shifts and VSI feature with two sampling intervals is more efficient than FSI feature. When small changes in the production process have occurred, CUSUM chart with small reference values will be recommended in terms of the time to signal.

Multivariate control charts for monitoring correlation coefficients in dispersion matrix

  • Chang, Duk-Joon;Heo, Sun-Yeong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.5
    • /
    • pp.1037-1044
    • /
    • 2012
  • Multivariate control charts for effectively monitoring every component in the dispersion matrix of multivariate normal process are considered. Through the numerical results, we noticed that the multivariate control charts based on sample statistic $V_i$ by Hotelling or $W_i$ by Alt do not work effectively when the correlation coefficient components in dispersion matrix are increased. We propose a combined procedure monitoring every component of dispersion matrix, which operates simultaneously both control charts, a chart controlling variance components and a chart controlling correlation coefficients. Our numerical results show that the proposed combined procedure is efficient for detecting changes in both variances and correlation coefficients of dispersion matrix.