• 제목/요약/키워드: Lightning protection system

검색결과 134건 처리시간 0.025초

피뢰설비현장의 접지 및 전기적 연속성 시험에 따른 표준적용 (The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field)

  • 송길목;구경완
    • 전기학회논문지
    • /
    • 제63권4호
    • /
    • pp.583-588
    • /
    • 2014
  • In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.

지중배전계통의 뇌과전압 해석 및 뇌써지 보호방안에 관한 연구 (A Study on the Lightning Overvoltage Analysis and Lightning Surge Protection Methods in Underground Distribution System)

  • 김상국;정채균;이종범;하동혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.558-560
    • /
    • 2003
  • The effects of surge arresters for protection of transmission systems against direct lightning strokes have already been investigated using the digital simulation program EMTP. Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. This paper analyzes the overvoltages on underground cable system against direct lightning strokes to the overhead ground wire using the digital simulation. The effects of lightning protection methods, such as lowering the grounding resistance and installing the surge arrester, for preventing overvoltages on underground cable system caused by direct lightning strokes to the overhead ground wire is investigated. Several schemes have been proposed to protect underground cables. This paper summarizes the main results of a study aimed at analysis of lightning overvoltages in variety underground feeders protected by metal-oxide arresters. This study will provide insulation coordination methods for reasonable system design in 22.9kV underground cable system.

  • PDF

비행체 시스템과 구조물의 낙뢰 보호 적합성 입증방법에 관한 고찰 (A Study on Means of Compliance for Lightning Protection in the System and Structure of Air Vehicles)

  • 정덕영
    • 항공우주시스템공학회지
    • /
    • 제14권spc호
    • /
    • pp.49-55
    • /
    • 2020
  • 항공사에서 운용되는 수송급 항공기는 평균적으로 연 1회(또는 1,000~20,000 비행시간 당 1회) 낙뢰에 피격되는 것으로 추정된다. 그러나 피격 확률이 중요한 것이 아니라 항공기가 낙뢰에 피격된다는 사실이 중요하다. 그러므로 인증 과정에서 항공기의 낙뢰보호설계가 검증되고 낙뢰 관련 감항기준에 대한 적합성이 입증되어야 한다. 본 논문에서는 우선적으로 우리나라 최초로 민간 형식증명을 획득한 KC-100 비행기 및 일부 시험 사례 분석을 통해 낙뢰에 대한 적합성 입증방법을 고찰하였다. 향후 본 논문을 바탕으로 우주발사체에 대한 낙뢰 영향성도 고찰해 볼 필요가 있다.

인하도선으로 활용하기 위한 철근콘크리트구조물의 전기 및 기계적 소요 특성에 대한 실험적 검증 (Experimental Verification on the Use of Steelwork as a Down-Conductor in Lightning Protection System)

  • 이기홍
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.94-99
    • /
    • 2011
  • This paper verified the characteristics of electrical continuity and mechanical strength of steelwork required to use it as a down-conductor in lightning protection system. It was proven that the steelwork in reinforced concrete apartment has an excellent electrical continuity with low resistance(less than 0.2[${\Omega}$].). But it was confirmed that a poor connection between two reinforcement bars can easily cause serious damages of the concrete even with the impulsive current of 50[kA], 10/350[${\mu}s$]. These results of experiments mean that the additional measures are necessary in using the steelwork as the down-conductor of the lightning protection system.

전기화재 예방을 위한 낙뢰 및 써지 보호시스템 개발에 관한 연구 (A Study on Development of Lightning and Surge Protection System for Electrical Fire Prevention)

  • 곽동걸
    • 마이크로전자및패키징학회지
    • /
    • 제13권3호
    • /
    • pp.27-32
    • /
    • 2006
  • 최근 기상이변으로 인한 낙뢰 및 써지의 발생빈도가 증가하고 있으며, 이에 따른 피해규모도 해마다 증대되고 있는 실정이다. 이들을 해결하기위한 보호시스템 개발이 다국적 관심분야로 대두되고 있다. 본 논문에서는 낙뢰와 전력 통신시스템에서 발생하는 각종 써지를 억제하기위한 새로운 구조의 보호시스템을 제안한다. 종래의 써지 보호장치들은 써지전류를 접지로 흘리는 구조로 설계되어 낙뢰, 송배전선로의 지락 및 혼촉 등 써지전류가 클 경우에 상승된 대지전위로 인해 전자 통신장비 및 기기들에 2차적 피해요인을 가져오는데 비해, 제안된 보호시스템은 대지전위의 상승을 억제하는 구조로 설계되어 2차적 피해가 발생하지 않는 이점이 있다. 개발된 써지 보호시스템의 실용성이 다양한 사고발생 시뮬레이터에 의해 입증된다.

  • PDF

복합재항공기 연료시스템의 낙뢰보호설계 및 인증 연구 (Research on Aircraft Lightning Protection Design and Certification of Fuel System in Composite Material)

  • 이영제;조원일;전정환;고진환
    • 한국항공운항학회지
    • /
    • 제25권4호
    • /
    • pp.130-140
    • /
    • 2017
  • Lightning protective design of an aircraft fuel system is closely related to the safety of the flight. Recently, composite material in building an aircraft becomes more important because it can reduce the weight of the aircraft. The composite materials decrease the protection against the effect of lightning. Lightning protective design of metal material aircraft has been researched for a long time and the design technique has been announced widely. However, research on the lightning protective design using composite material aircraft is very limited. In this study, lightning protective design for fuel tank structural component, access cover, fuel filler cap and drain valve in carbon fiber composite material aircraft have been presented. To show the compliance with FAA airworthiness standard regarding the presented protection designs, three steps, including lightning strike analysis, lightning environment analysis and certification test, were conducted in accordance with FAA AC 20-53.

A Novel Approved Mathematical Equation for Lightning Protection Angle

  • Singhasathein, Arnon;Rungseevijitprapa, Weerapun;Pruksanubal, Aphibal
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.1021-1029
    • /
    • 2018
  • During the past few decades, the lightning protection angle (${\alpha}$) has been proposed through several technical matters, namely graphical technique, numerical data and mathematical equation respectively. Nevertheless, these techniques are very complicated, and are difficult to utilize because they also contain several constraints practically. Hence, this paper proposes a novel equation of the lightning protection angle, which is a simple correlation, concise and easy to be implemented. Furthermore, the reliable result of this equation can confirm accuracy through comparative analysis with all previous techniques. As a result, these solutions are altogether equivalent. This novel equation can analyze the lightning protection angle of the vertical air termination system installed at the vertex of the royal pagoda in a Khema-pirataram temple which is at high risk due to lightning flashes.

기후변화에 따른 낙뢰사고 예방을 위한 제도 방안 연구 (A Study on the Prevention of Lightning Accidents According to Climate Change Response)

  • 주석원;김성빈;이동호
    • 한국가스학회지
    • /
    • 제24권4호
    • /
    • pp.48-55
    • /
    • 2020
  • 낙뢰 보호 시스템의 설치는 증가하고 있으나, 피해량은 여전히 줄지 않고 있다. 이 연구에서는 피뢰시스템의 안전관리 방안의 제도적 개선을 위한 목적으로 피뢰시스템에 관한 기준을 파악하고 현장조사와 설문을 통해 피뢰 시스템의 설치, 운영, 유지보수 등 실증분석을 실시했다. 국가표준 KS C IEC 62305에서 정하고 있는 기준 및 규정을 만족하지 못하는 것으로 파악되며, 이러한 문제를 해결할 수 있도록 국가적인 차원에서 피뢰시스템의 안전인증제품 관리, 안전기준의 설계·제작·시공 등 관리 기준이 이행 될 수 있도록 관련 규정 재정립을 통한 안전관리 방안을 제시한다.

뇌보호시스템에서 인하도선의 효과적인 설치기법 (Effective Installation Methods of Down Conductors in Lightning Protection Systems)

  • 이복희;엄주홍;이승칠;강성만
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.8-14
    • /
    • 2002
  • 현대의 뇌보호시스템은 낙뢰로 인한 감전이나 건축물, 전기·전자기기의 파손과 같은 위험성을 제거하는 것이 요구되지만 종래의 뇌보호설비는 단지 인명의 피해나 건축물을 보호하는 것이 주된 역할이었다. 오늘날 컴퓨터, 정보통신설비 등을 효과적으로 보호할 수 있는 뇌보호설비가 필수적 요건으로 대두되었다. 본 논문에서는 뇌과전압으로부터 컴퓨터와 전자장비를 보호할 수 있는 기술을 개발할 목적으로 인하도선의 종류와 설치기법에 따라서 인하도선에 유도되는 전위상승 억제에 대한 연구를 수행하였다. 그 결과 인하도선의 전위상승에 의한 측면방전과 위험성을 줄이기 위해서는 인하도선으로 낮은 특성임피던스를 가지는 동축케이블이 적당하며, 인하도선과 금속관을 상단과 하단에서 본딩하는 방법이 효과가 높게 나타났다.

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF