• 제목/요약/키워드: Lightning Surge

검색결과 291건 처리시간 0.025초

특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성 (Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines)

  • 심서현;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.

혼합배전계통 선로구성요소 변화를 고려한 선로 서지해석 (Surge Analysis Considering Variation of Line Configuration Factor in Combined Distribution Systems with Power Cables)

  • 김병숙;이장근;한병성;이종범
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.472-480
    • /
    • 2007
  • This paper analyzes overvoltage on testing line for various parameter effect examination. Model systems consist of overhead line and underground cable. The model considered actual characteristic data of distribution lines. and will be constructed at testing yard. The simulations were performed under various line configuration such as cable kinds, cable length, lightning wave, lightning wave time, transformer and branch circuits. The simulation models are established by EMTP/ATPDraw and Line Constants are calculated by ATP_LCC. When lightning surge strikes on conductor of overhead line, EMTP/ATPDraw calculates overvoltage in many cases. Simulation results will be compared with real testing results at testing yard. The compared results will be used to establish protection methods in actual underground distribution systems.

지중송전계통에서 불평형 구성요소에 따른 과도현상 해석 및 평가 (Transient Phenomena Analysis and Estimation According to Unbalance Factors on Underground Power Cable Systems)

  • 정채균;이종범;강지원;이동일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권8호
    • /
    • pp.410-417
    • /
    • 2005
  • This paper analyses the transient phenomena against single line to ground fault and lightning surge on underground power cable systems. For analysis in various fault conditions, several actual underground power cable systems are modeled using ATP In ground fault, the transient characteristic of the conductor and the sheath according to the fault current and the installation types of CCPU are analysed. In lightning surge strokes, the various unbalanced conditions including the length of crossbonded lead, the breakdown of CCPU and distance unbalance are considered. This paper is expected to contribute the establishment of proper protection methods against transients on underground power cable systems.

지중송배전계통에서 과도상태시 공통접지의 영향 분석 (Analysis of Common Grounding Effect during the Transient State in Underground Transmission and Distribution Systems)

  • 임광식;이종범
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.191-197
    • /
    • 2008
  • This paper describes the effect of transient state in underground transmission and distribution lines installed together in the same tunnel. Two systems installed in the same tunnel are operated by the common grounding. This paper analyzed that how much one of the two kinds of systems influences the other systems during the transient state by EMTP/ATPDraw. Single line-to-ground fault and lightning surge were selected in transient state condition. These cases were simulated variously according to the variation of common grounding magnitude, fault location and lightning surge magnitude. It is evaluated that the analyzed results will be used for establishment and operating materials of common grounding in the same tunnel.

Analysis of Transient Overvoltages within a 345kV Korean Thermal Plant

  • Yeo, Sang-Min;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.297-303
    • /
    • 2012
  • This paper presents the simulation results for the analysis of a lightning surge, switching transients and very fast transients within a thermal plant. The modeling of gas insulated substations (GIS) makes use of electrical equivalent circuits that are composed of lumped elements and distributed parameter lines. The system model also includes some generators, transformers, and low voltage circuits such as 24V DC rectifiers and control circuits. This paper shows the simulation results, via EMTP (Electro-Magnetic Transients Program), for three overvoltage types, such as transient overvoltages, switching transients, very fast transients and a lightning surge.

배전선로의 유도뢰 해석 (Analysis on Overvoltage induced on Power Distribution line by Lightning surge)

  • 김헌준;최상열;정호성;신명철;박남옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.279-281
    • /
    • 1998
  • This paper present overvoltage induced on distribution power line by lightning surge. It is important problem that overvoltage threatens credit and security of the power system. In this paper induced overvoltage was calculated. From the line being modeled in really actual practice. Also, the proper suppressing effects of a surge arrester against lightning induced voltages were suggested.

  • PDF

세라믹 필터를 이용한 동축 서지어레스터의 잔류전압 저감 (Residual Voltage Reduction of Coaxial Surge Arrestor Using Ceramic Filler)

  • 엄주홍;조성철;이태형;이영철
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.46-53
    • /
    • 2007
  • 현재 급속한 발전을 거듭하고 있는 이동통신 및 무선 멀티미디어 관련 서비스(W-CDMA, DMB, WiBro 등)의 확장은 이들 시스템을 구현하기 위한 수많은 기지국과 안테나 및 다수의 신호전송선로를 필요로 한다. 기지국 또는 중계시설의 안테나는 신호전송선로를 통하여 고가의 통신 네트워크 장비들과 결합되어 있으므로 주요 통신기기 시스템은 안테나를 통해 유입하는 직격뢰 및 유도뢰에 의한 순간적인 과전압의 위험에 항시 노출되어 있다. 현재 통신용 보호기로 사용되고 있는 가스방전튜브(GDT) 또는 협대역 스터브형 어레스터는 고속 광대역의 통신설비에 대한 뇌서지 보호수단으로서는 한계점이 드러나고 있다. 따라서 본 연구에서는 안테나를 통해 입사하는 뇌서지를 효과적으로 저감시켜주는 서지어레스터의 성능향상을 위해 세라믹 필터를 적용하였으며, 잔류전압 저감에 효과적임을 성능실험을 통해 입증하였다.

낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작 (Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection)

  • 길형준;송길목;김영석;김종민;김영진
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

정보통신설비용 뇌서지 보호장치의 효과적인 설치기법 (An Effective Installation Method of lightning Protective Devices for Information and Communication Facilities)

  • 이복희;이동문;강성만;엄주홍;이승칠
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.90-96
    • /
    • 2002
  • 정보통신망 신호선로는 전원선과 더불어 가공선로로 구성되어 있어 뇌서지에 대한 노출이 심각하다. 전원선로의 접지와 통신선로 접지 상호간에 나타나는 전위차로 인하여 통신선에 접속된 전자장비는 뇌서지에 의해 쉽게 손상될 수도 있다. 본 연구에서는 뇌서지로부터 정보통신설비를 신뢰성 높게 보호하는 기법을 개발할 목적으로 실규모 회로에서 서지보호장치의 성능과 신뢰성에 대한 실증실험을 수행하였다. 전원선과 통신선을 통하여 입사한 뇌서지 에 대한 서지보호장치의 동작특성과 보호장치의 설치방법이 뇌서지 보호효과에 미치는 협조특성을 평가하였다. 그 결과 정보통신설비용 뇌서지 보호장치를 바이패스 어레스터를 이용한 공통접지법으로 설치하는 것이 매우 효과적임을 확인하였다.

뇌임펄스전압에 대한 30[A]용 고감도형 누전 차단기의 오동작에 대한 특성의 해석 (Analysis of Malfunction Characteristics of High Sensitivity Type Earth Leakage Circuit Breaker for 30[A] due to Lightning Impulse Voltages)

  • 이복희;이승칠;김찬오
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권6호
    • /
    • pp.96-103
    • /
    • 1997
  • 본 논문은 뇌임펄스전압에 대한 누전 차단기의 오동작 특성에 관한 것으로 한국공업규격 KS C 4613의 규정과 서지보호장치를 갖는 모의회로의 조건에서 누전차단기의 부동작 특성을 실험적으로 조사하고 검토하였다. 실험 결과, 본 연구에 사용한 30[A]용 고감도형 누전 차단기인 모든 시료는 증폭회로의 전원부에 설치된 서지보호장치에 의해 입사되는 차동모드의 뇌임펄스전압에 차단되는 성능을 가지고 있었다. 4종의 시료는 KS C 4613에 정의된 뇌임펄스 부동작시험조건을 만족시키지 못하였으며, 그때의 오동작을 유발한 전압은 약 5∼6.5[kV]로 비교적 높았다. 서지보호장치가 설치된 경우를 모의한 시험조건에서는 3종의 누전차단기가 오동작하였으며, 누전차단기가 오동작을 일으키는 전압도 약 3∼5[kV] 정도로 비교적 낮았다.

  • PDF