• 제목/요약/키워드: Lightning Arrester

검색결과 147건 처리시간 0.031초

열화정도에 따른 배전용 피뢰기의 열화특성 분석 (Analysis of degradation of distribution lightning arresters as degradation degree)

  • 장동욱;박동배;박영국;이용희;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.140-143
    • /
    • 2000
  • The primary function of ZnO lightning arrester is to protect transmission and distribution equipment from overvoltages and to absorb electrical energy resulting from lightning or switching surges and form temporary overvoltage. However, ZnO lightning arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage and ambient temperature. So, it is important to the leakage current measurement of ZnO lightning arrester. In addition, since the resistive leakage current caused by deterioration of ZnO lightning arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. The leakage current and third harmonic component are measured and used to investigate the degradation diagnosis of ZnO element of arrester. Also the SEM photography is used to investigate the change of crystal structure of ZnO element with degradation.

  • PDF

뇌서지로 인한 피뢰기 열화시 과도상태 분석 (Transient State Analysis in Case of Lightning Arrester Deterioration due to Lightning Surge)

  • 임성용;김규호;이상봉;김수배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.276-277
    • /
    • 2015
  • As the effect of global warming continues, surge rates in Korea are also getting increased. Although there are devices to protect distribution line from the surge like lightning arrester, insulation of the lightning arrester can be destroyed if frequent surge occurs in distribution line. This paper assumed that the lightning surge hits the lightning arrester and make this device's insulation destroyed. This paper also simulated these processes utilizing EMTP/ATPDraw and verified voltage behavior when faults such as line to ground fault due to frequent lightning surge occur in lightning arrester.

  • PDF

배전계통에서 낙뢰보호용 피뢰기의 접지저항 영향에 관한 연구 (A Study on the Grounding Resistance Effects of Lightning Arrester for Lightning Stroke Protection in Electric Distribution Systems)

  • 김경철;정지원;이규진
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.107-114
    • /
    • 2010
  • 낙뢰는 구름이 가진 높은 전압이 대지로 방출되는 현상이다. 낙뢰 보호 접지는 낙뢰로부터 건물, 배전선로와 전기설비를 보호하는 중요한 역할을 한다. 기기 접지는 제한된 중성점 전위상승을 위한 목적으로 한다. 기기 접지는 제한된 중성점 전위상승을 위한 목적으로 한다. 본 논문에서는 낙뢰가 배전선로에 급습했을 때 중성점 전위와 피뢰기의 제한 전압을 분석하여 피뢰기 접지저항의 영향을 심도 있게 조사하였다. 사례연구는 EDSA 프로그램으로 수치와 그래프로 시뮬레이션하였다.

154kV 변전소에서 피뢰장치의 뇌서지특성 해석 (A Study on the Analysis of the Lightning Surge Characteristics of Arresters in a 154kV Substation)

  • 윤창섭;조한구;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.433-439
    • /
    • 2006
  • This paper describes the characteristic evaluation of 154kV lightning arrester developed by domestic technology. To prove the protective ability of lightning arrester developed, various overvoltages were analyzed for A and B arrester were being used now at 154kV air and gas insulation substation, and for arrester developed. The results obtained by the various simulations show that the developed arrester has the effective protective ability and reducing ability of the overvoltage as A and B arrester, nevertheless there are somewhat differences among three kinds of arresters. Accordingly, it is evaluated that the arrester developed by domestic technology secured reliability can be installed actually at 154kV substation. In this paper, EMTP/ATP was used for simulation.

다중 뇌충격전류에 의한 산화아연형 피뢰기 소자의 특성 변화 (Characteristic Changes of ZnO Arrester Blocks by Multiple-lightning Impuse Currents)

  • 길경석;한주섭
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.685-690
    • /
    • 2000
  • Multiple-lightning impulse currents are a general feature of the lightning ground f=flash. It is therefore necessary for lightning arresters used in power systems to be estimated by applying not only a single-lightning impulse current but also a multiple-lightning impulse currents. This paper presents the effects of multiple-lightning impulse currents on deterioration of ZnO arrester blocks. The multiple-lightning impulse generator which can produce quadruple 8/20$[\mus]$ 5[kA] with separation time of 30~120[ms] is designed and fabricated. The total energy applied to the arrester block at each impulse is about 1,200[J]. In experiment, various parameters such as leakage current component, reference voltage, and temperature are measured with the number of applied impulse current. Also, micro-structure changes of the ZnO blocks after applying the single and the multiple-lightning impulse currents of 200 times are compared. The experimental results indicate that the types of arrester blocks are more vulnerable to deterioration or damage by multiple-lightning impulse currents.

  • PDF

다양한 손상상태를 반영한 피뢰기 설비의 지진취약도 해석 (Seismic Fragility Analysis of Lightning Arrester Considering Various Damage States)

  • 신유성;송종걸
    • 한국지진공학회논문집
    • /
    • 제18권1호
    • /
    • pp.19-28
    • /
    • 2014
  • The seismic evaluation of electric power facilities in the switchyard of nuclear power plants is currently insufficient. In order to evaluate the seismic performance of lightning arrester subjected to four types of earthquake (near- and far-fault earthquakes, NEHRP Site Class A&B and D earthquakes), seismic fragility analysis using maximum likelihood estimation is performed considering various damage states. The comparison of the seismic fragility curves for three main parts of lightning arrester that are the busing, anchor and steel frame, reveals that the failure of lightning arrester is governed by the bushing damage mode such as porcelain cracking.

개폐서지 및 뇌충격 섬락시험에 따른 송전 피뢰기의 직렬공극 특성 (Series-Gap Characteristics of Transmission Line Arrester with Switching and Lightning Impulse Flashover Test)

  • 조한구;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.484-485
    • /
    • 2007
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

Study on Enhancing Lightning Protection Scheme of Catenary in Subway Viaduct Section

  • Li, Rui-Fang;Chen, Kui;Chen, Li-Sheng;Cao, Xiao-Bin;Wu, Guang-Ning;Zhang, Xue-Qin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.950-958
    • /
    • 2017
  • Viaduct increases the height of subway catenary, namely magnifies lightning attraction scope that lead to higher possibility of suffering lightning stroke. Therefore, it is necessary to analyze performance of lightning striking to catenary of subway in viaduct section and propose an improving lightning protection scheme. In this paper, using ATP-EMTP simulation software to establish an associated model to evaluate lightning withstand level of catenary with existing lightning protection schemes including arrester and grounding point, an improving lightning protection scheme is proposed - every pillar ground earth and arresters are installed with some installing spacing between 200m to 400m based on lightning damage degree and reliability requirements - according to analyzing results: while lightning withstand level is lowest for lightning striking to the neutral pillar, lightning withstand level is greatest for lightning striking to the both-ends pillar that arrester and grounding point are both installed; grounding point could obviously improve lightning withstand level for lightning striking to ground wire while arrester could obviously improve the lightning withstand level for lightning striking to catenary; every pillar ground earth could enhance the lowest lightning withstanding level up to 2.5 times than of that pillar ground earth across every 200m.

C/H 철탑 종단접속함 보호용 피뢰기 리드선 길이에 따른 뇌과전압 분석 (Analysis on Lightning Overvoltage According to Lead Length of Surge Arrester for Underground Cable Outdoor Termination Protection at C/H Tower)

  • 정채균;강지원
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.257-263
    • /
    • 2016
  • This paper describes the lightning arrester transients in cable head termination. The installation references of cable head tower and lightning arresters are firstly reviewed, then the performance of lightning arrester operation is also evaluated based on lightning overvoltage analysis by the change of grounding lead cable length. This paper finally proposes the optimal length of grounding lead cable at the cable head termination. The limited lightning current is also proposed according to the change of grounding lead cable length. The results will contribute to protecting insulation breakdown failure against lightning surge at the terminations and joints.

뇌임펄스 전류에 의한 ZnO 배전용 피뢰기의 열화특성 (Degradation properties of ZnO surge arrester due to lightning impulse current)

  • 이승주;이복희;이수봉;김동성;신희경;정동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1305-1306
    • /
    • 2008
  • In this work, in order to investigate the effect of lightning impulse currents on ZnO surge arrester. and the deterioration characteristics of ZnO surge arrester, 8/20 [${\mu}s$], 2.5 [kA] impulse currents were applied to the ZnO surge arrester under test. The leakage currents of ZnO surge arrester were measured and ZnO element was analyzed by X-ray photoelectron spectroscopy. As a result, the resistive leakage current of ZnO surge arrester was increased with the injection number of lightning impulse currents.

  • PDF