• Title/Summary/Keyword: Lighting Program

Search Result 211, Processing Time 0.032 seconds

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

The Blind Modeling of Horizontal Blind Using the RADIANCE Program (RADIANCE프로그램을 이용한 블라인드 모델링)

  • 정근영;최안섭
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.91-95
    • /
    • 2002
  • This study is using the RADIANCE lighting simulation tool to determine the transmittance where the horizontal blind is installed. The transmittance is applied to DayDim program which is a lighting calculation and analysis tool. Parameters such as clear sky type, seasonal changes(the summer solstice), altitude, azimuth and horizontal blind angle at a 0$^{\circ}$, 45$^{\circ}$, 90$^{\circ}$ were considered. The simulation results present that measured directional transmittances have different values according to each directional property of the horizontal blind.

  • PDF

Spectral analysis of a sunlight collector system and its application example (태양광 채광시스템의 스펙트럼 분석 및 조명 적용 예)

  • Park, Jun-Seok;Eo, Ik-Soo;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2162-2164
    • /
    • 2000
  • In this paper, it is analysed the spectrum of optical fiber output through a sunlight collector system. Also the lighting environments under the optical fiber bundles are predicted when applied to interior lighting by using a simulation program. As the result its feasibility as an interior lighting source shows any serious problem except the system cost.

  • PDF

A New LED Light Device Lighting Control Algorithm for Optimal Energy Saving (최적의 에너지 효율을 위한 새로운 LED 조명기기 점등제어 알고리즘)

  • In, Chi-Goog;Hong, Sung-Il;Chang, Jeong-Uk;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.17-23
    • /
    • 2012
  • In this paper, we were proposed a new LED light device lighting control algorithm for optimal energy saving. The propose lighting control algorithm be to the LED lights devices lighting control by measuring illuminance into multi sensors. And it be to lighting control by inverting of octagon pattern during set-up time. All the LED is lighting when detecting motion by the motion sensor. And, it was designed enable remote management control by communicate with central monitoring center using Zigbee wireless network to measured data from sensors at real time. In this paper, a proposed lighting control algorithm was measured power consumption about the lighting status of LED lighting device using the lighting control program for demonstrate of energy savings effect. The measured result, the lighting method applying proposed algorithm were proved energy savings effect of more 40% more compared to the existing lighting method.

Assessment of BIN Method to Predict Energy Saving in Office Building Using the RADIANCE Program (RADIANCE 프로그램을 이용한 오피스 건축물에서의 에너지 절감율 예측을 위한 BIN Method 검토)

  • Hong, Seong-Kwan;Park, Byoung-Chul;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.154-159
    • /
    • 2008
  • Daylight is an important component for human and energy saving. Also, available daylight in inside provides positive influence on psychological and physiological aspects as well as good visual environment. It is important to lighting design for office building not only designing for artificial lighting but also using daylight for energy savings. Therefore, lighting designers and architectures must consider the effects of the daylight for human environment and energy savings. The BIN Method is one of the methods to predict energy savings using computer simulation but it spends more time than expectation. So, this study performs to simulate a simple space using the RADIANCE for examination and simplification of the BIN Method.

  • PDF

A study of Illumination on Floor Surface by Flat Form Louver of Top Lighting System (천창루버에 의한 내부공간 바닥면 조도변화와 설치방식에 관한 연구)

  • Kim, Mi-Hee;Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.132-138
    • /
    • 2011
  • Inducing the natural lighting into building has been commonly applied to the spaces where artistic objects are displayed to create better visual environment for the appreciation. The direct natural lighting, especially through top lighting system may, however, bring forth discoloing of highly light-sensitive materials such as paintings or demanding additional cooling load. In addition, it causes to create glare against appreciators or to yield in visual distraction due to the extreme contrast on the inner surfaces of the spaces. Shading device such as louver is capable of preventing such voidable cases with careful manipulation. This study aims to provide basic design guide-line when the flat-form louver has to be applied to top lighting system. Interaction between the daylight and louver was simulated by Reluxpro program with variation of the attachment location, the angle of the lover, surface reflectivity, to obtain the illumination of the floor surface. This study yields the louver just under the top lighting window with 90 degree angle gives the most desirable way of employment when the uniform illumination on the floor surface is required.

Analyze the Results of Lighting Type Change and Rroposal of Power Density per Unit Area for Light Pollution Control of Channel-letter Type Advertisement Lighting (채널레터형 광고조명의 빛공해 관리를 위한 조명방식 개선효과 분석 및 단위면적당 소비전력(W/㎡) 제한 방법 제안)

  • Yoo, Seongsik;Kim, Hyun-Ji;Kim, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.759-766
    • /
    • 2018
  • Although the Act on the Prevention of Light Pollution Due to Artificial Lighting has been enforced since 2013, the area of advertisement lighting has made slow progress in solving the problems of light pollution. This paper first investigated institutional problems by analyzing domestic laws and regulations relating to the light pollution of advertisement lighting, and investigated and analyzed methods for reducing light pollution that were applied in overseas countries. Then, problems of light pollution were analyzed by conducting a research on the actual status of advertisement lightings installed in South Korea and applying various methods for reducing light pollution, and advertisement lighting using LED was recommended. As a method for reducing light pollution that can be applied to the process of manufacturing channel letter-type advertisement lights, power consumption per unit area ($W/m^2$) was proposed, and $100W/m^2$ was recommended as a value currently suitable for South Korea.

A study on the design and performance of a stand-alone photovoltaic lighting system (독립형 태양광 조명 시스템의 설계 및 성능 평가 연구)

  • Kwon, Oh-Sang;Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.1-10
    • /
    • 2004
  • In view of global environmental problems and resource exhaustion, we must develop new energy resources that are abundant and provide substitutes for fossil fuels. Renewable energies, such as solar, are ideal because they are clean, inexhaustible, and available everywhere in the world. Photovoltaic(PV) system, in general, are operated as a stand-alone, grid-tied, or hybrid system. Many of the stand-alone PV systems are installed. Although the pre-installation cost of PV system is high, it poorly has been operated due to the absence of optimal management standards. Therefore a study on the performance of PV system is important for the system design and maintenance. In this paper a photovoltaic lighting system was resigned according to load consumption. Then a PV lighting system which used electrodeless lamp as a load was installed. In order to investigate the system operating characteristics we've added a monitoring system to the PV lighting system. The monitoring system using the LabVIEW program regularly checks the operation of the PV lighting system and records the system data. According to the system data, the stability and availability of the PV lighting system were evaluated.

The Tunnel Lighting Design Using a Computer Simulation Program (Computer Simulation Program을 이용한 터널조명설비의 설계)

  • 박상훈;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.234-239
    • /
    • 1999
  • 도로터널 조명설비의 합리적인 설계로 도로터널의 안전한 교통운행 확보와 쾌적한 운전 환경을 위하여 Computer Simulation Program을 이용한 최적의 터널조명환경을 조성하고 그 결과를 분석·검토하여 설계에 적용하고 조명설비 공사에 반영하며, 발생하는 문제점과 그 대책을 제시하고자 한다.

  • PDF

Load Pattern Considerations of The Photovoltaic Lighting System by Using Computer-based Date Acquisition System (컴퓨터기반의 DAS를 적용한 태양광 조명설비의 운용패턴 고찰)

  • 황명근;허창수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.1-10
    • /
    • 2003
  • Comparing to the conventional power systems, PV(photovoltaic) outdoor lighting system applications are evaluated as the most economical application. In this paper, we installed two PV lighting systems, which uses LPS(low pressure sodium) and electrodeless lame as their loads, and applied a computer-based data acquisition system using the Labview program for monitering purpose and effective operations, considering battery life time Also, we observed the generated power from the solar array, and energy losses comparing to its installed capacity. Because most PV system performance procedures have looked at the performance of the individual components and have deficiency of addressing how the integrated system works, we confirmed the decrease possibility of the solar amy capacity after analyzing the performance of the installed PV lighting systems.