• Title/Summary/Keyword: Lighting Performance

Search Result 688, Processing Time 0.022 seconds

Effect of Different Lighting Sources on Behavior and Growth of Weanling Pigs

  • Glatz, P.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.2
    • /
    • pp.280-287
    • /
    • 2001
  • These studies aimed to determine how lighting might be used to improve feed intake and reduce aggressive behavior in newly weaned pigs. To examine whether this objective could be achieved an experiment was conducted to compare performance, behavior and body condition of weaners over 17-45 days, provided similar lighting quality (i.e. color temperature, color rendering index and lighting distribution) after weaning that piglets experienced prior to weaning. Triphosphor (TP) lighting to simulate daylight was provided during the day while at night, Pascal red (PR) lighting was provided to simulate the night-light piglets previously had received from infrared heating lamps. This treatment was compared to weaners provided conventional cool-white fluorescent light during the day only. Weaners on treatment lighting from 17-45 days of age showed no improvement in body weight or feed conversion at 24, 31, 38 and 45 days compared to the controls. There was, however, a significant improvement (p<0.05) in feed intake in the first week of weaning for weaners provided TP/PR lighting. Over the first 3 days of weaning, pigs on TP/PR lighting showed an increase (p<0.05) in the incidence of ear chewing but reduced (p<0.05) levels of nosing the abdomen of other pigs and reduced (p<0.05) occurrences of being stood on by other pigs. Females exhibited more (p<0.05) mounting and nosing behaviors and rubbing the heads of other pigs than males. On the other hand, males engaged in more (p<0.05) fighting, nipping, ear chewing and standing on other pigs compared to females. Pigs provided PR lighting on the first night of weaning engaged in higher (p<0.05) incidences of nosing and tail sucking behaviors, more (p<0.05) head thrusting, fighting and ear chewing compared to control pigs. The body condition of weaners provided the TP/PR lighting treatment was significantly poorer (p<0.05) compared to weaners on control lighting. In conclusion there was no improvement in production performance of weaners provided new technology lighting apart from the improvement in feed intake in the first week weaners were exposed to the TP/PR lighting.

A Basic Study on Performance Evaluation of Permanent Supplementary Artificial Lighting of Interior(PSALI) using a LED Light Source (LED광원을 이용한 실내상시보조인공조명(PSALI)의 성능평가에 관한 기초적 연구)

  • Lee, Jin-Sook;Kim, Byoung-Soo;Kim, So-Yeon;Jung, Young-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.16-23
    • /
    • 2011
  • Since the first lighting light source was invented, lighting has turned into superior-quality lighting considering the amenity of occupants, and the characteristics of a light source has developed rapidly. So this research confirmed the lighting performance of a dimmer control system and an ON-OFF control system via the existing light source, and analyzed the basic lighting environment of Permanent Supplementary Artificial Lighting of Interiors(PSALI) through the physical comparison and evaluation of a LED lamp substituted for a fluorescent lamp used in a dimmer control system, showing that the lighting physical quantity characteristics of an ON-OFF control system and a dimmer control system are similar to each other and that they are effective in terms of energy saving. Besides, it was shown that introducing a LED light source to a dimmer control system improves lighting environments and largely reduces energy consumption.

Empirical Evaluation of Optimal User-Centered LED Lighting Environments in Residential Bathrooms

  • Lee, Jeongmin;Choi, Kyungah;Suk, Hyeon-Jeong
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2013
  • This user-centered research aims to empirically evaluate color temperature (K) and illuminance (lx) of residential bathroom lightings to determine the most optimal lighting conditions for productive task performance as well as for satisfying users' emotional needs. Using 3 LED lighting fixtures, 4 types of lighting contexts were investigated; main lighting, task lighting, shower lighting, and bath lighting. Two lightings were installed parallel to the vertical edges of the main bathroom mirror to be used as main and task lighting, while another fixture was installed above the bathtub to be used for shower and bathing. For each lighting context, subjects (N=54) were instructed to perform a few tasks during which time the users were exposed to different lighting conditions with color temperature ranging from 2700 K ~ 6500 K and illuminance ranging from 100 lx ~ 700 lx. Upon completing the given tasks, subjects were asked to evaluate the lighting conditions and their applicability for performing the given tasks. Based on the user evaluations, the most optimal lighting conditions for the different lighting scenarios are as follow: 1) 3500 K ~ 4300 K and 150 lx for main lighting, 2) 3500 K ~ 4300 K and 500 lx ~ 700 lx for task lighting, and 3) 2700 K ~ 3500 K and 100 lx ~ 150 lx for shower/bath lighting. These results can be used to adjust the lighting standards suggested by KS, as well as be utilized by both engineers and designers in designing new types of user-centered bathroom lightings.

  • PDF

Analysis of Mental Fatigue of Inspection Workers under Various Lighting Conditions (조명조건의 변화에 따른 검사작업자의 정신적 피로도 분석)

  • Jang, Tong-Il;Lim, Hyeon-Kyo
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.114-120
    • /
    • 2006
  • Inspection works are mainly carried out with the help of human sensory organs and are relatively simple and repetitive, so that the workers easily become to feel fatigue and monotony, and their mental activity levels attenuate. Consequently, during the work time, it is natural that various lighting conditions around the workplaces may have in-fluence on work performance. This study aimed to analyze cortical fatigue of inspection workers. Thus, an inspection work was simulated on a computer monitor under various lighting conditions, and CFF, EEG, EOG, and HRV were analyzed. According to the results, fatigue symptoms turned up about $60{\sim}90$ minutes after the onset of the work. The work performance also decreased when the fatigue symptoms due to lighting conditions turned up. The variations of fatigue and work performance were affected by illuminators, illumination levels, or interaction of those two factors. The spiral fluorescent lamp seemed improper to the inspection work, because the work performance under that condition was lower than under any other illuminators.

A Study of Characteristics of Heat Dissipation Carbon Magnesium New Materials of LED Lighting (LED 조명용 카본 마그네슘 신소재 방열 특성 연구)

  • Son, Il-Soo;Shin, Sung-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.12
    • /
    • pp.915-919
    • /
    • 2013
  • This is the study on the development of fusion heat dissipation of carbon magnesium materials. The purpose of this study is for effective utilization of heat emission which is the core of LED lighting. The result of study enabled the derivation of side satisfying result of making the surface temperature of lighting to be below $70^{\circ}C$ (actual measurement: $58^{\circ}C$) using magnesium. The lighting products that use magnesium was made possible based on the result of this study. Also from the performance aspect such as light distribution, the measurement of light efficiency demonstrated the level of 90 lm/W. Therefore the commercialization of lighting was made possible and the efficiency could be further enhanced by supplementation of LED performance.

Study on the Thermal Behavior of Immersion Cooled LED Lighting Engines (담금 냉각되는 LED 조명엔진의 열특성에 대한 연구)

  • Kim, Kyoung Joon
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.87-92
    • /
    • 2014
  • This study is aimed at investigating the thermal behavior of immersion-cooled high power LED lighting engines. 3D CFD models have been generated for the numerical analysis. Five cases in terms of the configuration of LED chips have been explored for various passive cooling conditions of the lighting engine, i.e., the natural air convection with a lens, the natural air convection without a lens, the deionized water-immersion cooling condition with a lens. The numerical study reveals that the deionized water-immersion cooled lighting engine has nearly twice better thermal performance than the natural air convection cooled lighting engine containing a lens. The investigation has also demonstrated that the four chips configuration has the better thermal performance than the single chip configuration.

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

A study on the design and performance of a stand-alone photovoltaic lighting system (독립형 태양광 조명 시스템의 설계 및 성능 평가 연구)

  • Kwon, Oh-Sang;Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.1-10
    • /
    • 2004
  • In view of global environmental problems and resource exhaustion, we must develop new energy resources that are abundant and provide substitutes for fossil fuels. Renewable energies, such as solar, are ideal because they are clean, inexhaustible, and available everywhere in the world. Photovoltaic(PV) system, in general, are operated as a stand-alone, grid-tied, or hybrid system. Many of the stand-alone PV systems are installed. Although the pre-installation cost of PV system is high, it poorly has been operated due to the absence of optimal management standards. Therefore a study on the performance of PV system is important for the system design and maintenance. In this paper a photovoltaic lighting system was resigned according to load consumption. Then a PV lighting system which used electrodeless lamp as a load was installed. In order to investigate the system operating characteristics we've added a monitoring system to the PV lighting system. The monitoring system using the LabVIEW program regularly checks the operation of the PV lighting system and records the system data. According to the system data, the stability and availability of the PV lighting system were evaluated.

Evaluation of Lighting Performance of Mixed Type Light-shelf in Residential Space According to Angular Variations (주거공간의 혼합형 광선반 각도 변화에 따른 채광성능 평가)

  • Chae, Woori;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.424-433
    • /
    • 2014
  • The purpose of this study is to evaluate the effectiveness in the lighting performance of mixed type light-shelf, by comparing and analyzing the internal light-shelf, external light-shelf, and mixed-type light-shelf. The performance of light-shelf was evaluated according to the angle of light-shelf at summer solstice, winter solstice, vernal equinox, and autumn equinox. The comparative analysis between the internal light-shelf, external light-shelf, and mixed-type light-shelf was carried out using the performance evaluation and analysis method. The result of performance evaluation is shown as follows. The mixed type light-shelf showed the highest lighting performance all at summer solstice, winter solstice, vernal equinox, and autumn equinox, followed by the external light-shelf and the internal light-shelf in the same order. The mixed type light-shelf was the most favorable for bringing daylight to indoors by adjusting the angle of light-shelf, and it also showed the highest lighting performance in terms of uniformity ratio of illumination which indicates the quality of light.

Prediction of Contrast and Lighting Energy Saivings in a Small Office Space according to Daylight Conditions (소규모 사무실공간에서 주광조건에 따른 대비효과 및 조명에너지 절약예측)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.35-43
    • /
    • 2004
  • Illuminance and luminous levels in a small office space due to daylight were calculated to analyze the impact of daylight on contrast and lighting energy savings. Computer simulations were performed for four blind conditions under a clear sky condition. The blind conditions significantly impacted the illuminance an4 luminance level. Visual performance scores were calculated according to the transfer function that uses absolute contrast between target and background surface. The blind condition that had 45 tilted angle toward ground provided good contrast and performance scores. Using a control algorithm of an automated daylight dimming control system lighting energy sayings were predicted. For all blind conditions minimum lighting energy was consumed.