• Title/Summary/Keyword: Light response

Search Result 1,447, Processing Time 0.03 seconds

A Study on the Light Stimulus of Organic Thin Films (유기박막의 광 자격에 관한 연구)

  • 김성진;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.283-286
    • /
    • 2000
  • In this paper, generation form of displacement current was compared and measured induce monolayers which 8A5H with Pure azobenzene. Light response of two monolayers which compared and measured though they are the same isomer. The experimental results are as following; In case of ultraviolet($\lambda_1$) and visible($\lambda_2$) irradiation on 8A5H induce monolayers depositioned on board the peak of current was detected about 10[fA]. but light irradiation on pure azobenzene any particular reaction for detailed. This is the reason of hydrophobicity construct in molecule structures its molecule dynamic behaviour in cis and trans was not due to activated.

  • PDF

Effect of Blue, Red and Far-red Lights on Seeding Growth and Cotyledon Chlorophyll Content of Lagenaria siceraria Standl (광질처리에 따른 박 유묘의 생장 및 자엽의 엽록소 함량 변화)

  • 강진호;전병삼
    • Journal of Life Science
    • /
    • v.11 no.2
    • /
    • pp.166-172
    • /
    • 2001
  • Various types of the seeding of bottle gourd widely used as a rootstock of watermelon has been required to satisfy the farmers need. The study was done to determine the effect of light quality of blue, red and far-red lights treated with light emitting diodes on growth and morphology of bottle goured seeding and chlorophyll content of its cotyledons. The lights were treated in the growth chamber for 7 days to the seeding elapsed 8 days after sowing under natural condition, and 64 hole trays with commercial bedsoil. Plant height, length and diameter of hypocotyl, leaf area of cotyledon and first true leaf, its leaf length, number of true leaves, fraction and total dry weight were measured. Red light shortened and slenderized the hypocotyl, which lengthened by far-red light and thickened by blue light. Plant height was declined in order of far-red light treatment, blue and red lights mainly due to difference of hypocotyl length, Area and length of the first true leaf became smaller and shorter under far-red light than under the other lights. However, blue light increased leaf area of cotyledons. Two cultivars cv. Yongjadaemok and cv. Kunghap had different response to the light treatments in total seedling dry weight(dw); far-red and red light treatments showed the greatest and the least dw of hypocotyl, respectively, while blue and red lights did the greatest dw of the other organs. Among the ratio of each organ dw to total dw, those of hypocotyl and true leaves were different between the light treatments; the highest ratio of hypocotyl dw to total dw was observed in far-red light treatment but the lowest was in red light treatment. Those of the true leaves were the lowest in far-red light and similar response in blue or red light treatment. Chlorophyll content of cotyledons was decreased in order of red light treatment, blue and far-red lights, meaning that short period light treatment may influence photosynthesis of seeding and afterward its growth.

  • PDF

Development of Quantification Method for Bioluminescence Imaging (발광영상에 대한 정량화 방법 개발)

  • Kim, Hyeon-Sik;Choi, Eun-Seo;Tak, Yoon-O;Choi, Heung-Kook;Lee, Ju-Young;Min, Jung-Joon;Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.451-458
    • /
    • 2009
  • Purpose: Optical molecular luminescence imaging is widely used for detection and imaging of bio-photons emitted by luminescent luciferase activation. The measured photons in this method provide the degree of molecular alteration or cell numbers with the advantage of high signal-to-noise ratio. To extract useful information from the measured results, the analysis based on a proper quantification method is necessary. In this research, we propose a quantification method presenting linear response of measured light signal to measurement time. Materials and Methods: We detected the luminescence signal by using lab-made optical imaging equipment of animal light imaging system (ALIS) and different two kinds of light sources. One is three bacterial light-emitting sources containing different number of bacteria. The other is three different non-bacterial light sources emitting very weak light. By using the concept of the candela and the flux, we could derive simplified linear quantification formula. After experimentally measuring light intensity, the data was processed with the proposed quantification function. Results: We could obtain linear response of photon counts to measurement time by applying the pre-determined quantification function. The ratio of the re-calculated photon counts and measurement time present a constant value although different light source was applied. Conclusion: The quantification function for linear response could be applicable to the standard quantification process. The proposed method could be used for the exact quantitative analysis in various light imaging equipments with presenting linear response behavior of constant light emitting sources to measurement time.

Electro-optical properties of photo-aligned VA-LCD by irradiation of unpolarized UV light. (비편광 UV조사에 의한 광배향 VA-LCD의 전기광학특성)

  • 박두석;서대식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.545-548
    • /
    • 1999
  • The electro-optical characteristics of photo-aligned vertical-alignment (VA)-liquid crystal display (LCD) with non-polarized ultraviolet (UV) light irradiation of 45\`on homeotropic polyimide (Pl) surface were investigated. LC alignment on photo-aligned VA-LCD is attributed to photo-depolymerized reaction of the polymer with non-polarized UV light irradiation on PI surface. We had good voltage-transmittance (V-T) characteristics of photo-aligned VA-LCD. The response time of photo-aligned VA-LCD was slower than that of the rubbing-aligned VA-LCD. Finally, we suggest that the slow response time of photo-aligned VA-LCD depends on the LC domain.

  • PDF

Effect of Light-Emitting Diodes on Cordycepin Production in Submerged Culture of Paecilomyces japonica

  • HA, Si Young;JUNG, Ji Young;YANG, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.548-561
    • /
    • 2020
  • Paecilomyces japonica is widely cultured to produce mycelium for medicinal and health food use. Illumination is an important factor in the growth and production of mycelium in submerged culture. The effects of different light-emitting diode (LED) combinations on the growth and cordycepin content as bioactive substances of mycelium were investigated. The results showed that the mycelium dry weights were lower under dark condition and red LED treatments. Dark condition, fluorescent light, and ultraviolet-A failed to increase the cordycepin content. Blue light was necessary to increase the cordycepin content, and a red-to-blue ratio of 3:7 induced the highest cordycepin content. The cordycepin contents of mycelium in submerged culture were significantly higher in a 12 h/day illumination time under red and blue (red-to-blue ratio of 3:7) LED treatments, showing an increase of up to 38% compared with those under the fluorescent-light control condition. The results demonstrated the roles of light with different wavelengths on the biosynthesis of cordycepin as bioactive substances. The low-heat release and replacement of traditional fluorescent lights with low-energy-consuming LEDs could increase the contents of bioactive substances. After optimization of the cordycepin production using response surface methodology (Box-Behnken design) to its canonical form, the optimum combination was found to be as follows: illumination time = 17.7 h/day, sugar content in the medium = 9.7 g/50 mL, and incubation time = 61.2 h. The model predicted a maximum response of 3779.2 ㎍/mL cordycepin yield.

The Electrophysiology Application on Guard Cells to See the Influence of Carbon Dioxide

  • Lee, Joon-Sang
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.763-770
    • /
    • 2014
  • The effect of $CO_2$ on the opening of stomata in the intact leaf of Commelina communis has been investigated. Full opening of stomatal apertures(around $18{\mu}m$) was achieved in the intact leaf by addition of $CO_2$($900{\mu}mol\;mol^{-1}$). At 90 minutes, the stomatal apertures of leaves treated with $CO_2$ free air were reduced. In contrast, stomata opened most widely with the treatment of $CO_2$ air at 90 minutes. The effects of light, $CO_2$ air and $CO_2$ free air on the change of membrane potential difference(PD) were measured. Fast hyperpolarization of guard cell membrane PD was recorded reaching up to -12 mV in response to light. If $CO_2$ free air was given firstly, there was no response. When light was given after $CO_2$ free air, the light effect was very clear. At the onset of $CO_2$ air, the PD showed a dramatic hyperpolarization to about -25 mV. Changes in the pH of apoplast in intact leaves in response to $CO_2$ air were observed. $CO_2$ air caused a change of 0.4 pH unit. Therefore, it can be hypothesized that $CO_2$ flowing could stimulate proton efflux which is a necessary precursor of stomatal opening.

A Study on Emergency Response Plan for Manless Light Rail Transit(LRT) (무인 경량전철 운영을 위한 비상대응 계획 수립에 관한 연구)

  • Park, Min-Kyu;Shin, Jong-Hyun;Kim, Yeon-Woong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.915-923
    • /
    • 2011
  • Our country is promoting the introduction of new means of transportation due to insufficient supply according to the existing demand of road traffic. Among them, manless light railroad transit is settled down as the most definite alternative. However, new traffic systems such as manless light railroad have certain difference between characteristics of hardware and software and subway system. Therefore, there will be many differences compared to the existing contingency system when accidents occur. Railway management organization has to establish railway contingency plan and acquire permission from the minister of the Ministry of Land, Transport, and Maritime Affairs. However, as commercial transportation is available, a new traffic system also should establish contingency plan. Therefore, the establishment of systematic contingency plan is suggested in order to analyze characteristics of manless light railroad in the beginning of introduction and to make contingency response available.

  • PDF

Transmittance and Responce Properties of the Light Transmission Controllable Films Prepared with Dipole Particles Suspension (분극성입자 현탁액을 이용한 투과도 가변필름의 투과도 및 응답특성)

  • 이영우;김응수;유병석;이정훈
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.1
    • /
    • pp.131-139
    • /
    • 1995
  • In order to improve transmittance and response properties, various compositions of light controllable films were prepared by phase separation method. The optical and response properties were measured with the variation of PMMA/suspension ratio and block copolymer/light polarizing particles. According to the increase of the PMMA/suspension ratio, the separated droplets of suspension were interconnected in the film. Decay time was 2.6 sec when PMMA/suspension ratio was 0.5 : 1 and ΔT(difference of the transmittance at OFF/ON states) was reduced with increasing of the ratio of PMMA/suspension. On block copolymer/light polarizing particles ratio variation, the highest transmittance of the film was 67.4% when its ratio was 0.6 : 1 and decay time was varied from 2.15 to 46.6 sec as block copolymer content increased 0.2 : 1 to 1 : 1.

  • PDF

Structural Optimization of a Light-weight Manhole Cover Using FEM and Response Surface Method (유한요소법과 반응표면법을 이용한 경량 맨홀 커버 구조 최적화 설계)

  • Lee, Hyoungwook
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.462-470
    • /
    • 2016
  • The locking load of a conventional manhole depends on the weight of its cover. Locking-type manhole structures with a special locking mechanism were recently developed to prevent accidents such as stolen cover, away cover from a frame. The weight of the manhole structure can be reduced under structural safety because the locking force of a locking-type manhole is greater than the weight of the cover. A light-weight manhole cover is developed in this study by using a finite element stress analysis and the design of experiments. Static stress analysis and fracture experiments are also conducted to analyze the states of the initial product. The optimum light-weight manhole cover considering manufacturing molds is developed and tested. Consequently, the weight was found to reduce by 16%. In addition, the fracture load increased by 38%.

Alignment of transmitters in indoor visible light communication for flat channel characteristics

  • Curuk, Selva Muratoglu
    • ETRI Journal
    • /
    • v.44 no.1
    • /
    • pp.125-134
    • /
    • 2022
  • Visible light communication (VLC) systems incorporate ambient lighting and wireless data transmission, and the experienced channel in indoor VLC is a major topic that should be examined for reliable communication. In this study, it is realized that multiple transmitters in classical alignment are the forceful factors for channel characteristics. In the frequency band, fluctuations with sudden drops are observed, where the fluctuation shape is related to the source layout and receiver location. These varying frequency-selective channels need solutions, especially for mobile users, because sustained channel estimation and equalization are necessary as the receiver changes its location. It is proven that using light-emitting diodes (LEDs) with highly directional beams as sources or using a detector with a narrow field of view (FOV) in the receiver may help partially alleviate the problem; the frequency selectivity of the channel reduces in some regions of the room. For flat fading channel characteristics all over the room, LEDs should be aligned in hexagonal cellular structure, and detector FOV should be arranged according to the cell dimension outcomes.